Actisense A2K-FFC Right Angle Connector Male Installation Guide
- June 17, 2024
- Actisense
Table of Contents
Right Angle A2K-FFC
Installation Instructions
A2K-FFC Right Angle Connector Male
Tools Required:
Stanley knife
Wire cutters
Wire strippers
2mm flat head screw driver
Step One:
Disassemble the Field Fit Connector and slide the base nut, securing gland and
plastic collar (see Fig.1) over the cable. Leaving the main body until after
the wires are stipped will make inserting the cable easier.
Strip back 25mm from the outer sheath of your DeviceNet cable to expose the
individual wires and then remove the screens.
Cut 10mm off of the blue (NET-L) wire, leaving 15mm, as this fits to the
terminal that sits higher than the others on the screw head.
Strip 5mm of insulation from the end of all the wires.
Step Two:
Pass the stripped wires through the main body. You may wish to use a screw
driver to help bend the wires past the corner inside.
Slide the securing gland and plastic collar up inside the main body and secure
the base nut tight enough so it doesn’t move during installation of the screw
head.
Step Three:
Loosen the individual screws on each pin and insert the correct wire in
accordance with Table.1 and Fig.2 one at a time.
Tighten the terminal screws as firmly as possible to secure the wire inside
the pin.
Wire Colour | Connector Pins | Name |
---|---|---|
Green/Bare | Pin 1 | Shield |
Red | Pin 2 | NET-S |
Black | Pin 3 | NET-C |
White | Pin 4 | NET-H |
Blue | Pin 5 | NET-L |
Step Four:
Loosen off the base nut to allow you to pass the cable back through the main
body and attach the screw head.
The screw head on the right angled connector has been designed to allow
installation at five different angles, providing full installation
flexibility.
Screw the main body and screw head firmly together.
Secure the base nut to ensure a watertight connection.
References
Read User Manual Online (PDF format)