BRT Sys PD40 Display User Guide
- June 17, 2024
- BRT Sys
Table of Contents
BRT Sys PD40 Display
Product Features
Please visit http://brtsys.com/warranty or scan the QR code for warranty
registration with the UUID and Product Key below STICKER AREA
Specifications
- Display Installation: RJ45-JST8 cable
- Maximum RJ45 8P8C cable length for single PD40 Display connection to PanL Hub port: 100 meters
- Mounting options: wall mount, glass mount, 86-type electrical box mount, and metal electrical box mount
- Device ID range: 0-7 (8-9 reserved)
Product Usage Instructions
Display Installation
To connect the PD40 Display to a suitable PanL Hub port, use the provided
RJ45-JST8 cable in the PD40 product package.
Note : If using an extension cable that is a plug-to-plug type (e.g., Ethernet patch cable), an RJ45 socket to RJ45 socket adapter needs to be used.
Mounting
Wall Mount
A maximum of 4 PD40 Displays can be connected to a single PanL Hub port.
The first connection to the PanL Hub and the subsequent connections in between
the PD40 Displays must not exceed 50 meters in cable length. The total
combined cable lengths must not exceed 100 meters. 1 to 2-port RJ45 adapters
are needed. The last device ID must be set to 7. See ID Switch Configuration.
Glass Mount
86 Type Electrical Box Mount
Wall Box Mount
Refer to the datasheet for detailed instructions on mounting the PD40 Display
using the PD40 Rear Cover Mounting Bracket P/N: PA001500A or PD40 Wall Box
Mounting Bracket P/N: PA001400A.
ID Switch Configuration
The ID switch at the back of the PD40 Display can be configured for unique
settings. Use a Philips head screwdriver to set a unique number between 0-7
(8-9 are reserved).
- For a single device connected to PanL Hub, the ID must be configured to 7 to enable the RS485 terminator.
- For multiple PD40 Display connections to a single PanL Hub port, the ID switch must be configured to be unique. The last device ID must be configured to 7 to enable the RS485 terminator.
- PD40 devices connected to different PanL Hub ports can use the same ID number.
Device Start-up Animation/Image After Power-Up
The PD40 Display will display the following startup animation/image after
connecting to the PanL Hub and powering ON:
- Startup Animation
- Idle Page
- Before Configuration
FCC Statement
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of the FCC RF
Rules. This equipment must not be co-located or operating in conjunction with
any other antenna or transmitter.
FAQ
-
Q: Where can I find detailed mounting instructions?
A: Please refer to the datasheet for detailed mounting instructions. -
Q: What is the maximum cable length for a single PD40 Display connection to a PanL Hub port?
A: The maximum length is 100 meters. -
Q: How many PD40 Displays can be connected to a single PanL Hub port?
A: A maximum of 4 PD40 Displays can be connected. -
Q: Can PD40 devices connected to different PanL Hub ports use the same ID number?
A: Yes, they can use the same ID number.
Product Features
- Buzzer – Trigger sound to user to signify an event
- Reset – Hardware reset PD40 device
Mounting
PD40 Display su p ports wall mount, glass mount, 86 type electrical box mount and metal electrical box mount. Please set the device ID (0-7) before assembling panel. Refer to ID Switch Configuration section. Refer to the datasheet for detailed instructions.
- Wall Mount
- Glass Mount
- 86 Type El ectrical Box Mount
- Wall Box Mount PD40 Rear Cover Mounting Bracket P/N:PA001500A
PD40 Wall Box Mounting Bracket P/N:PA001400A
Display Installation
- Use the RJ45-JST8 cable (provided in the PD40 product package) to connect the PD40 Display to a suitable PanL Hub port.
- For a single PD40 Display connection to a PanL Hub port, the maximum length of the RJ45 8P8C cable is 100 meters. The RJ45-JST8 cable has an RJ45 plug. Therefore, note that an RJ45 socket to RJ45 socket adapter needs to be used if the extension cable is a plug-to-plug type such as an Ethernet patch cable.
- A maximum of 4 PD40 Displays can be connected to a single PanL Hub port. The first connection to the PanL Hub and the subsequent connections in between the PD40 Displays must not exceed 50 meters in cable length. The total combined cable lengths must not exceed 100 meters. 1 to 2-port RJ45 adapters are needed. The last device ID must be set to 7. See ID Switch Configuration.
ID Switch Configuration
- ID switch at the back of the PD40 display can be configured for unique settings. Use a Philips head screwdriver to set a unique number between 0-7 (8- 9 are reserved).
- For a single device connected to PanL Hub, the ID must be configured to 7 to enable the RS485 terminator.
- For multiple PD40 Display connections to a single PanL Hub port, the ID switch must be configured to be unique. The last device ID must be configured to 7 to enable the RS485 terminator.
- PD40 devices connected to different PanL Hub ports can use the same ID number.
Device Start-up Animation/ Image After Power Up
PD40 will display the following startup animation/image after connecting to the PanL Hub and powering ON.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a building installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of the FCC RF
Rules. This equipment must not be co-located or operating in conjunction with
any other antenna or transmitter.
Please visit http://brtsys.com/warranty or scan the QR code for warranty registration with the UUID and Product Key below:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>