BRT Sys IoTPortal Gateway Owner’s Manual
- September 30, 2024
- BRT Sys
Table of Contents
IoTPortal Gateway
“`html
Specifications
Model: IoTPortal Gateway
Version: 1.4
Document Reference No.: BRTSYS_000007
Clearance No.: BRTSYS#002
Product Information
Features
The IoTPortal Gateway allows LDSBus protocol-based devices to
communicate with BRTSys’s IoTPortal Cloud services without the need
for a PC. Real-time monitoring, alert notifications, and control
automation can be configured through the cloud via the IoTPortal
Mobile app. The gateway connects to the cloud via Wi-Fi or Ethernet
and can be powered via POE or an external DC adaptor.
The gateway features 3 LDSBus RJ45 ports for data communication
and power interface to the LDS bus network, with each port
supporting multiple LDSBus Quad T-Junctions and up to 4 LDSBus
Devices (sensors/actuators) per junction with a distance of up to
200 meters.
Applications include remote environment monitoring, agriculture
monitoring, smart building automation, data center and industrial
monitoring, etc.
Part Numbers / Ordering Information
Part Number | Description |
---|---|
LG010101A | IoTPortal Gateway (POE Version) |
LG010201A | IoTPortal Gateway (PSU Version) |
LA090101A | LDSBus M2M RJ12-USBA Cable (1.8 m) |
LA100101A | LDSBus M2M RJ12-UART WE Cable (1.0 m) |
LA110101A | LDSBus M2M RJ12-RS485 cable (1.8 m) |
LA120101A | LDSBus DIN Rail Mount Set |
LA070101A | IoTPortal Gateway PSU |
Product Usage Instructions
Connecting the Gateway
1. Connect the IoTPortal Gateway to a power source using either
POE or an external DC adaptor.
2. Connect the gateway to the cloud via Wi-Fi or Ethernet.
Setting Up Devices
1. Connect LDSBus Devices to the Gateway using RJ45 cables.
2. Each port supports multiple Quad T-Junctions, with each
junction supporting up to 4 devices.
Configuring Applications
1. Use the IoTPortal Mobile app to configure real-time
monitoring, alert notifications, and control automation.
Frequently Asked Questions (FAQ)
Q: What is the distance limit for connecting LDSBus Devices to
the Gateway?
A: Each Quad T-Junction supports devices up to a distance of 200
meters from the Gateway.
Q: Can the Gateway be powered using both POE and an external DC
adaptor simultaneously?
A: No, the Gateway can be powered using either POE or an
external DC adaptor, not both simultaneously.
“`
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.:BRTSYS_000007 Clearance No.: BRTSYS#002
IoTPortal Gateway
Datasheet
1 Introduction
1.1 Features
The IoTPortal Gateway allows a wide variety of LDSBus protocol based LDSBus
Devices (sensors/actuators) to communicate with BRTSys’s IoTPortal Cloud
services without the need for a PC. Real time monitoring, alert notifications
and control automation can be configured through the cloud via the IoTPortal
Mobile app. The IoTPortal Gateway connects to the cloud via Wi-Fi or Ethernet
and is powered either via POE or an external DC adaptor (PSU).
The gateway comes with 3 LDSBus RJ45 ports which serve as data
communication/power interface to the LDS bus network. Each port can be
connected to multiple LDSBus Quad T-Junctions using RJ45 cables (Cat5e) and
each Quad T-Junction supports up to 4 LDSBus Devices (Sensors/Actuators) with
a distance reaching up to 200 meters.
Applications include remote environment monitoring, agriculture monitoring and
control, smart building automation, data center and industrial monitoring etc.
Please visit Resources – BRT Systems for more information on the Gateway and
the IoTPortal.
IoTPortal Gateway features include:
· Connect IoT sensors/actuators to the BRTSys’s IoTPortal Cloud to enable
monitoring, alert, and control features
· Connect to wired sensors/actuators based on the BRT Sys’s LDSBus protocol
· Sensor/Actuator connectivity reaching up to a distance of 200 meters
· Ethernet Port with 10/100BASE-T · Wi-Fi 802.11 b/g/n · POE Gateway version
supports both IEEE802.3af and
IEEE802.3at standards · 3 LDSBus RJ45 ports provide power and support data
communication · Machine-to-Machine communication port · 8MB non-volatile
storage for sensor report storage
during off-line condition · Support for Over The Air (OTA) firmware updates ·
Built in temperature sensor · Built-in Over current protection · Flush Mount
and DIN Rail Mounting options · PSU (DC Power adaptor): 24VDC/65W · Operating
Temperature: 0oC to +55oC
Neither the whole nor any part of the information contained in, or the product described in this manual, may be adapted, or Reproduced in any material or electronic form without the prior written consent of the copyright holder. This product and its documentation are supplied on an as-is basis and no warranty as to their suitability for any particular purpose is either made or implied. B RT Systems Pte Ltd (BRTSys) will not accept any claim for damages howsoever arising as a result of use or failure of this product. Your statutory rights are not affected. This product or any variant of it is not intended for use in any medical appliance, device, or System in which the failure of the product might reasonably be expected to result in personal injury. This document provides preliminary information that may be subject to change without notice. No freedom to use patents or other intellectual property rights is implied by the publication of this document. BRT Systems Pte Ltd, 1 Tai Seng Avenue, Tower A, #03-01, Singapore 536464. Singapore Registered Company Number: 202220043R.
Copyright © BRT Systems Pte Ltd
1
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
2 Part Numbers / Ordering Information
Part# LG010101A LG010201A LA090101A LA100101A LA110101A LA120101A LA070101A
Description IoTPortal Gateway (POE Version) IoTPortal Gateway (PSU Version)
LDSBus M2M RJ12-USBA Cable (1.8 m) LDSBus M2M RJ12-UART WE Cable (1.0 m)
LDSBus M2M RJ12-RS485 cable (1.8 m) LDSBus DIN Rail Mount Set IoTPortal
Gateway PSU
Table 1 Part Numbers / Ordering Information
Copyright © BRT Systems Pte Ltd
2
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
Table of Contents 1 Introduction …………………………………………………….. 1
1.1 Features …………………………………………………………………..1
2 Part Numbers / Ordering Information ………………….. 2
3 Specifications …………………………………………………… 5
4 FCC Compliance Statement …………………………………. 6
5 IoTPortal Ecosystem………………………………………….. 7
6 Hardware Features ……………………………………………. 8
6.1 IoTPortal Gateway (POE Version) ………………………………..8
6.2 IoTPortal Gateway (PSU Version) ………………………………..9
6.3 Mounting Options …………………………………………………….10
6.3.1 Flush Mount …………………………………………………………………………. 10 6.3.2 DIN Rail Mount
……………………………………………………………………… 10
6.4 Power Supply ………………………………………………………….11
6.4.1 POE Gateway ……………………………………………………………………….. 11 6.4.2 PSU Gateway
……………………………………………………………………….. 11
6.5 LDSBus Output Ports ………………………………………………..11
6.6 Machine to Machine (M2M) Port …………………………………11
6.7 Real Time Clock (RTC) ………………………………………………11
6.8 Reset ……………………………………………………………………..12
6.8.1 6.8.2
Hardware Reset (HRST) …………………………………………………………… 12 Configuration Reset (FRST) ………………………………………………………. 12
7 System Status LED Indicators……………………………. 14
7.1 Network and FRST Status LED Indicator (NET)……………..14
7.2 Power Status LED Indicator (PWR/POE) ……………………..14
7.3 Ethernet Port Status LED Indicator (ETH) ……………………15
7.4 LDSBus Port Status LED Indicator (LDSBus) ………………..15
8 Mechanical Dimension ……………………………………… 16
9 Contact Information ………………………………………… 17
Copyright © BRT Systems Pte Ltd
3
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
Appendix A References ……………………………………… 18
Document References ………………………………………………………18 Acronyms and
Abbreviations……………………………………………..18
Appendix B List of Tables & Figures …………………….. 19
List of Tables…………………………………………………………………..19 List of Figures
…………………………………………………………………19
Appendix C Revision History ………………………………. 20
Copyright © BRT Systems Pte Ltd
4
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
3 Specifications
Connectivity
Features
Power
Physical Characteristics Environmental Limits
Standards & Certifications
Standards & Certifications Package Contents Optional
LDSBus Devices Internet Cloud
BRTSys’s LDSBus protocol Wi-Fi: IEEE802.11 b/g/n (802.11n up to 150 Mbps) Frequency: 2.4 GHz ~ 2.5 GHz Antenna: On Board Antenna Ethernet: 10/100BASE-TX Ethernet Port, Autonegotiation
LDSBus Interface
3x RJ45 ports (RS485)
Machine to Machine Interface
1x RJ12 port (UART)
Power Indicator
1x Dual-color LED Red (PoE af), Orange (PoE at, DC input)
Network Indicator
1x RGB LED
LDSBus Port Indicator
3x Red LEDs
Sensor
Built in temperature sensor
Real Time Clock(RTC)
Yes
Battery
CR1225 3V/52mAh, 5-Year Life cycles
Hardware Reset
Yes
Factory Reset
Yes, Multi-function
Input
POE Gateway – PSE: IEEE802.3af standards IEEE802.3at standards PSU Gateway – 24VDC / 65W
Output (LDSBus Ports)
POE Gateway IEEE802.3af 24VDC, Max. 400mA / 9.6W IEEE802.3at – 24VDC, Max. 600mA/ 14.4W PSU Gateway – 24VDC, Max. 1500mA / 36W
Power Consumption
POE Gateway – Max. 20W PSU Gateway – Max. 40W
Color
White
Housing
Polycarbonate
Dimensions (mm)
148.8(L) X 81.0(W) X 31.9(H)
Weight
POE Gateway – 154 grams PSU Gateway – 140 grams
Operating Temperature
POE Gateway – 0 to +55°C PSU Gateway – 0 to +40°C
Storage Temperature
-20 to +85°C
Ambient Relative Humidity
5 to 95% (non-condensing)
EMC (FCC/CE)
EN 55032:2015+AC:2016 Class B BS EN 55032:2015+AC:2016 Class B EN IEC 61000-3-2:2019 Class A BS EN IEC 61000-3-2:2019 Class A EN IEC 61000-3-3:2013+A1:2019 BS EN IEC 61000-3-3:2013+A1:2019 EN 55024:2010+A1:2015 BS EN 55024:2010+A1:2015 EN 55035:2017+A11:2020 BS EN 55035:2017+A11:2020 FCC CFR Title 47, PART 15, Subpart B, Class B
Radio Equipment Directive (RED)
Safety (LVD)
EN 301 489-1 V2.2.3 EN 301 489-17 V3.2.4 IEC 62368-1:2014 EN 62368-1:2014 +A11:2017
RF (FCC/CE)
EN 300 328 V2.2.2 EN IEC 62311:2020 FCC PART 15, Subpart C (15.247)
POE Version
1x IoTPortal Gateway
PSU Version
1x IoTPortal Gateway 1x Power Adapter
Mounting Accessories
1x LDSBus DIN Rail Mount set (LA120101A)
Table 2 – IoTPortal Gateway Specifications
Copyright © BRT Systems Pte Ltd
5
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
4 FCC Compliance Statement
IoTPortal Gateway complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) These devices may not cause harmful interference, and
(2) These devices must accept any interference received, including
interference that may cause undesired operation.
NOTE: The equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If the equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
– Re-orient or relocate the receiving antenna. – Increase the separation
between the equipment and receiver. – Connect the equipment into an outlet on
a circuit different from that to which the receiver
is connected. – Consult the dealer or an experienced radio/TV technician for
help.
To maintain compliance with FCC’s RF exposure guidelines, at least 20cm of
separation distance between the IoTPortal Gateway device and the user’s body
must be maintained at all times.
FCC Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of the FCC RF
Rules. This equipment must be installed and operated in accordance with
provided instructions and the antenna(s) used for this transmitter must be
installed to provide a separation distance of at least 20 cm from all persons
and must not be co-located or operating in conjunction with any other antenna
or transmitter. End-users and installers must be provided with antenna
installation instructions and consider removing the nocollocation statement.
Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Contains FCC ID: 2AC7Z-ESPWROOM32D
Copyright © BRT Systems Pte Ltd
6
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
5 IoTPortal Ecosystem
Figure 1 shows the IoTPortal ecosystem with the IoTPortal Gateway serving as a
vital component connecting the LDSBus devices (Sensors/Actuators) to the
cloud.
Figure 1 – IoTPortal Ecosystem
Copyright © BRT Systems Pte Ltd
7
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
6 Hardware Features
6.1 IoTPortal Gateway (POE Version)
Port Status Indicator
Network Status Indicator Power Status Indicator
LDSBus Port 3x RJ45
POE Port Not-In Use
Figure 2 – IoTPortal Gateway (POE) – Top View
Mounting Hole
M2M RJ12
Hardware Reset
Factory Reset
Battery Switch Mounting Hole Battery
Figure 3 – IoTPortal Gateway (POE) – Side View
Copyright © BRT Systems Pte Ltd
8
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
6.2 IoTPortal Gateway (PSU Version)
Port Status Indicator
Network Status Indicator Power Status Indicator
LDSBus Port 3x RJ45
Ethernet Port Status Indicator DC power
Mounting Hole
Figure 4 – IoTPortal Gateway (PSU Version) – Top View
Battery Switch
M2M RJ12
Mounting Hole
Configuration Reset
Battery Hardware Reset
Figure 5 – IoTPortal Gateway (PSU Version) – Side View
Copyright © BRT Systems Pte Ltd
9
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
6.3 Mounting Options
6.3.1 Flush Mount
The IoTPortal Gateway can be flush mounted directly on a wall or any flat
surface using 2 M3.516mm (thread) screws.
2xM3.516mm
Figure 6 – IoTPortal Gateway Flush Mount
6.3.2 DIN Rail Mount
The IoTPortal Gateway can be mounted on a DIN Rail using the LDSBus DIN Rail
Mount set. This set is optional and includes the bracket and mounting screws.
DIN Rail Mount
Figure 7 – IoTPortal Gateway DIN Rail Mount
Copyright © BRT Systems Pte Ltd
10
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
6.4 Power Supply
6.4.1 POE Gateway
The IoTPortal Gateway shall be powered through an IEEE 802.3af or an IEEE 802.3at POE switch. The DC jack is not used in this version. Refer to Table 3 for details on the Power supply.
6.4.2 PSU Gateway
The IoTPortal Gateway shall be powered through a 24VDC / 65W adaptor. Refer to Table 3 for details on the Power supply.
Power Source
Input Voltage
IEEE802.3af IEEE802.3at Power Adaptor
37.0V~57.0V 42.5V~57.0V 24.0V / 65W
LDSBus
Max. Current
Port
(Per port)
Voltage
24.0V
400mA
24.0V
400mA
24.0V
500mA
Table 3 – Power Supply
Max. Current (3x ports)
400mA 600mA 1500mA
6.5 LDSBus Output Ports
The IoTPortal Gateway comes with 3 LDSBus ports that provide 24VDC bus power. LDSBus devices can be connected via Cat5e cable up to 200 meters. The Gateway scans each port for LDSBus devices and disables the port when no devices are detected or if device loading exceeds rated power.
6.6 Machine to Machine (M2M) Port
The IoTPortal Gateway also has an RJ12 port (Yellow) for communication between
machines. The M2M port is made up of an UART running at 115200 Baud rate,
8-N-1. AT commands may be sent to the gateway to achieve the following:
a. Send an email b. Send a push notification to a mobile number c. Send an SMS
to a mobile number d. Send a text message to a remote gateway using its UUID
6.7 Real Time Clock (RTC)
The IoTPortal Gateway synchronizes time using Network Time Protocol (NTP). In case NTP is not desired, then the onboard Real Time Clock may be used. The contents of the RTC are backed by a battery which can be switched on and off via the Battery Switch. A CR1225 coin battery is included (3V/52mAh) and battery life is approximately 5 years.
Copyright © BRT Systems Pte Ltd
11
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
6.8 Reset
There are two reset buttons on the IoTPortal Gateway, namely HRST and FRST.
6.8.1 Hardware Reset (HRST)
When HRST (Hardware Reset) is pressed, a system level, hardware reset is
initiated.
6.8.2 Configuration Reset (FRST)
FRST (Firmware Reset) is a menu driven firmware-controlled reset. Three
options are available on the FRST menu, and these are:
1. Initialize the gateway into Wireless Access Point (AP) mode for wireless
on-boarding 2. Reset gateway configuration 3. Factory Reset
6.8.2.1 Wireless Access Point
1. Press and hold the FRST button for 5 seconds and the NET status LED will
turn to solid red. 2. Release FRST and wait 10 seconds and the NET status LED
will blink red. 3. Wait another 5 seconds and the gateway will enter AP mode
and becomes discoverable 4. Onboarding shall begin within 60 seconds 5. After
60 seconds of no activity, the operation is cancelled, and gateway returns to
previous
state.
6.8.2.2 Reset Gateway Configuration
1. Press and hold the FRST button for 5 seconds and the NET status LED will
turn to solid red. 2. Release FRST and within 10 seconds, press and hold FRST
again for at least 2 seconds or
until NET status LED turns to solid cyan. 3. Release FRST and wait 10 seconds
and NET status LED turns to blink cyan to indicate
gateway configuration reset is initiated. 4. After releasing FRST in step 2
and followed by 60 seconds of no activity (no button
presses), the operation is cancelled, and gateway returns to previous state.
6.8.2.3 Factory Reset
1. Press and hold the FRST button for 5 seconds and the NET status LED will
turn to solid red. 2. Release FRST and within 10 seconds, press and hold FRST
again for at least 2 seconds or
until NET status LED turns to solid cyan. 3. Release FRST and within 10
seconds, press and hold FRST again for at least 2 seconds or
until NET status LED turns to solid orange. 4. Release FRST and wait for 10
seconds. NET status LED will blink orange to indicate factory
reset is initiated. 5. After releasing FRST in step 4, pressing FRST again
within 10 seconds will cancel the reset
operation.
Copyright © BRT Systems Pte Ltd
12
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
Figure 8 – IoTPortal Gateway Firmware – RESET Button Functionality Flow Diagram
Copyright © BRT Systems Pte Ltd
13
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
7 System Status LED Indicators
The following status indicators are available on the IoTPortal Gateway 1.
Network and FRST Status LED Indicator (NET) 2. Power Status LED Indicator (PWR
/ POE) 3. Ethernet Port Status LED Indicator (ETH) 4. LDSBus Port Status LED
Indicator (LDSBus)
7.1 Network and FRST Status LED Indicator (NET)
LED Color
Description
RED Stable
BLUE Blinking
BLUE Stable
GREEN Blinking
GREEN Stable
RED Blinking
YELLOW Blinking
Device is in bootup mode While connecting to network (either Ethernet or Wi-
Fi) Upon successful connection to network (either Ethernet or Wi-Fi)
While connecting to IoTPortal Cloud Upon successful connection to IoTPortal
Cloud If in Wi-Fi AP mode and waiting for configuration from Mobile app When
firmware upgrade (OTA) is in progress
Table 4 – IoTPortal Gateway Network and FRST Status LED Indicator
Note: Ensure that the unit is powered on throughout the OTA update process. A
power loss during the OTA update process may lead to malfunction of the device
7.2 Power Status LED Indicator (PWR/POE)
LED Color
Description
RED Stable
ORANGE Stable
Indicates that the device is Powered ON with POE that supports IEEE802.3af
Indicates that the device is Powered ON with POE that supports IEEE802.3at
or
Indicates that the device is Powered ON with +24VDC (PSU)
Table 5 – IoTPortal Gateway Power Status LED Indicator
Copyright © BRT Systems Pte Ltd
14
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
7.3 Ethernet Port Status LED Indicator (ETH)
LED
LED Color
Description
Off
Network link is down
Link Indicator
YELLOW Stable
YELLOW Blinking
Network link is up Network link is up and data transfer in progress
Speed Indicator
Off
GREEN Stable
If link indicator is yellow, network is operating at 10Mbps otherwise no speed
is available
Network is operating at 100Mbps
Table 6 – IoTPortal Gateway Ethernet Port Status LED Indicator
7.4 LDSBus Port Status LED Indicator (LDSBus)
LED Color
Off
REDBlinking
Description No communication is active. Indicates that the port is active, and communication is in progress Table 7 – LDSBus Port Status LED Indicator
Copyright © BRT Systems Pte Ltd
15
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
8 Mechanical Dimension
148.8 135.6
81.0
Figure 9 – IoTPortal Gateway Dimension – Top View
Figure 10 – IoTPortal Gateway Dimension – Side View
10.0
60.0
Figure 11 – IoTPortal Gateway Dimension – Bottom View Note: All dimensions are
in millimeters.
Copyright © BRT Systems Pte Ltd
16
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
9 Contact Information
Refer to https://brtsys.com/contact-us/ for contact information.
System and equipment manufacturers and designers are responsible to ensure that their systems, and any BRT Systems Pte Ltd (BRTSys) devices incorporated in their systems, meet all applicable safety, regulatory and system-level performance requirements. All application-related information in this document (including application descriptions, suggested BRTSys devices and other materials) is provided for reference only. While BRTSys has taken care to assure it is accurate, this information is subject to customer confirmation, and BRTSys disclaims all liability for system designs and for any applications assistance provided by BRTSys. Use of BRTSys devices in life support and/or safety applications is entirely at the user’s risk, and the user agrees to defend, indemnify and hold harmless BRTSys from any and all damages, claims, suits, or expense resulting from such use. This document is subject to change without notice. No freedom to use patents or other intellectual property rights is implied by the publication of this document. Neither the whole nor any part of the information contained in, or the product described in this document, may be adapted, or reproduced in any material or electronic form without the prior written consent of the copyright holder. BRT Systems Pte Ltd, 1 Tai Seng Avenue, Tower A, #03-01, Singapore 536464. Singapore Registered Company Number: 202220043R.
Copyright © BRT Systems Pte Ltd
17
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
Appendix A References
Document References
IoTPortal Gateway Quick Start Guide
Acronyms and Abbreviations
Terms IoT LED
LDSBus M2M OTA POE PSU RTC
Description Internet of Things Light Emitting Diode Long Distance Sensor Bus Machine to Machine Over The Air Power Over Ethernet Power Supply Unit Real Time Clock
Copyright © BRT Systems Pte Ltd
18
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
Appendix B List of Tables & Figures
List of Tables
Table 1 Part Numbers / Ordering Information ……………………………………………………………. 2 Table
2 – IoTPortal Gateway Specifications ………………………………………………………………….. 5 Table 3 –
Power Supply ………………………………………………………………………………………… 11 Table 4 – IoTPortal Gateway
Network and FRST Status LED Indicator ……………………………….. 14 Table 5 – IoTPortal
Gateway Power Status LED Indicator ……………………………………………….. 14 Table 6 – IoTPortal
Gateway Ethernet Port Status LED Indicator………………………………………. 15 Table 7 – LDSBus
Port Status LED Indicator……………………………………………………………….. 15
List of Figures
Figure 1 – IoTPortal Ecosystem ………………………………………………………………………………… 7 Figure 2 –
IoTPortal Gateway (POE) – Top View …………………………………………………………….. 8 Figure 3 –
IoTPortal Gateway (POE) – Side View ……………………………………………………………. 8 Figure 4 –
IoTPortal Gateway (PSU Version) – Top View…………………………………………………… 9 Figure 5 –
IoTPortal Gateway (PSU Version) – Side View………………………………………………….. 9 Figure 6 –
IoTPortal Gateway Flush Mount …………………………………………………………………. 10 Figure 7 –
IoTPortal Gateway DIN Rail Mount ……………………………………………………………… 10 Figure 8 –
IoTPortal Gateway Firmware – RESET Button Functionality Flow Diagram ……………… 13
Figure 9 – IoTPortal Gateway Dimension – Top View …………………………………………………….. 16
Figure 10 – IoTPortal Gateway Dimension – Side View…………………………………………………… 16
Figure 11 – IoTPortal Gateway Dimension – Bottom View……………………………………………….. 16
Copyright © BRT Systems Pte Ltd
19
IoTPortal Gateway Datasheet Version 1.4
Document Reference No.: BRTSYS_000007 Clearance No.: BRTSYS#002
Appendix C Revision History
Document Title: Document Reference No.: Clearance No.: Product Page: Document Feedback:
IoTPortal Gateway Datasheet BRTSYS_000007 BRTSYS#002 https://brtsys.com/iotportal/ Send Feedback
Revision Version 1.0 Version 1.1 Version 1.2
Version 1.3
Version 1.4
Changes
Initial Release
Document migrated to BRTSys
Updated the following HVT references to Quad T-Junction; Singapore address
Added a note related OTA under Section 7.1
Updated Section 3. Specifications
Date 27-10-2021 14-09-2022 11-09-2023
05-02-2024
04-09-2024
Copyright © BRT Systems Pte Ltd
20
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>