HINKLEY 46991BX LED Convertible Flush Mount Facet Instruction Manual
- June 17, 2024
- HINKLEY
Table of Contents
mounting instructions
Item No: 46991-46994
start here
46991BX LED Convertible Flush Mount Facet
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-TIONS (LS. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
STEP 1
- Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT restore current – either by fuse, breaker or switch – until the new fixture is completely wired and in place.
STEP 2
- In the following order : take retainer ring (L) , canopy (H) and slide them over the stems (R) attached previously.
- Thread supply wires (S) through center of swivel (E) that is attached to mounting strap (A).
- Slide swivel with mounting strap along wire and thread end of swivel into top of stems (R).
- Lift fixture and attach mounting strap (A) to junction box (C) using 2-8/32 screws (B) not provided.
- Make all necessary electrical connections following instruction sheet (IS-18) provided. Ground wire (D) can be attached to mounting strap (A) using green ground screw (G).
- Slip canopy (H) up along rods (R) and over mounting strap with swivel and hold in position.
- Slip retainer ring (I) up to canopy and thread onto coupler (F), to secure Canopy.
Note: Fixture can be covernted to a flush mount by removing swiviel (E) and using the supplied 4″ stem
Assembly Instructions
DRAWING 2-Shade install
- Place small diffuser (9) into small shade (10)
- Secure arms (5) to small shade(10) using screws(6)
- Place large diffuser (7) into large shade (8)
- Secure large shade (8) to top pan (1) using screws (3)
- Secure arms from small shade (5) to top pan (1) using screws (2)
- Use plastic plug to cover mounting holes
- Lamp fixture with appropriate medium base bulbs (4) (not supplied)
- Fixture can now be powered on
Drawing 1 – Flush Mount| Drawing 2 – Chain Hung| Drawing 3 –
Post-Mount
---|---|---
| |
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY
ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT
A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — – see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting
strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting
screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com