Specifications :

  • MOV provides spike and surge protection
  • Magnetic bond sensor monitor output
  • Door position status sensor output
  • Bi-color LED indicates lock/unlock status
  • Anodized aluminum housing
  • Anti-Residual magnetism designed
  • Complete mounting hardware included

Product Usage Instructions

Mounting the Electromagnetic Lock:
To mount the electromagnetic lock, follow these steps:

  1. Choose a suitable location on the door frame or adjacent wall for installation.
  2. Ensure that the surface is clean and free from any obstructions.
  3. Attach the mounting plate to the desired location using the provided screws.
  4. Place the electromagnetic lock onto the mounting plate and secure it using the provided screws.

Connecting the Wires:
To connect the wires for the electromagnetic lock, perform the following actions:

  1. Identify the power source for the lock and ensure it is turned off.
  2. Strip the insulation from the ends of the lock’s wires.
  3. Connect the positive (+) and negative (-) wires to the corresponding terminals on the power source.
  4. If applicable, connect the bond sensor and door position sensor wires to their respective terminals.
  5. Secure the wire connections with electrical tape or wire connectors.

Optional Bracket Installation:
If the door swinging direction or frame header requires additional support, install the optional brackets. Follow these steps:

  1. Identify the door swinging direction.
  2. Inspect the door frame header to determine if a bracket is required.
  3. Select the appropriate L-bracket, LZ-bracket, or U-bracket based on the frame header and swinging direction.
  4. Attach the bracket to the door frame using the provided screws.
  5. Mount the electromagnetic lock onto the bracket following the previous mounting instructions.

FAQ:

  • Q: How long is the warranty for the Electromagnetic Locks?
    A: The Electromagnetic Locks are warranted against defects in material and workmanship for a period of 1 year from the date of sale to the original customer.

  • Q: Are optional brackets necessary for all installations?
    A: Optional brackets may be required depending on the door swinging direction and frame header. It is recommended to inspect the door frame header to determine if a bracket is needed.

Electromagnetic lock user manual

Features

  • MOV provides spike and surge protection.
  • Magnetic bond sensor monitor output.
  • Door position status sensor output.
  • Bi-color LED indicates lock/unlock status.
  • Anodized aluminum housing.
  • Anti-Residual magnetism designed.
  • Complete mounting hardware included.

Statement

  • Electromagnetic lock build-in magnetic bond sensor output indicates the door opened or closed,with bi-colour LED indicates the EM-lock locked or unlocked status. The fail-safe Electromagnetic Lock design with no mechanical parts but magnetic force release the doors, suitable for use to secure and in areas which required access controlled or egress such as exit door We offers up to 280kg(600pounds) holding force and can be applied with access control, and with the full range of optional brackets, it can be installed on all type of door frames such as Hollow, Wooden and frameless glass door. Build in magnetic bond sensor output and bi-colour LED indicates the door locked or unlocked status.
  • It is the best choice for electronic security industry and system integrators. More optional functions are available in electromagnetic lock series.

Specifications

  • Voltage Tolerance: 115%
  • Current Draw: 400mA 12V DC (at temperature 200C )
  • Magnetic bond sensor monitor output (SPDT rated 1A 12V DC), remotely monitors the door lock or unlock status. (N.C. Output–Door opened; N.O. Output–Door closed)
  • Operating Temperature:-10-550C
  • Humidity: 0-95% non-condensing.
  • Lock’s surface Temperature (when the power is on): Scurrent temperature +200C
  • Holding Force: 280KG (600pounds)
  • Dimensions: Lock Size: (L) 250, (W) 48, (D) 26 mm
  • Mounting Plate Size : (L) 250, (W) 25, (D) 6 mm
  • Armature plate Size : (L) 180, (W) 38, (D) 11 mm
  • Special Finishes for magnet and armature plate: Zinc

Warranty

Electromagnetic Locks are warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer.

Optional Brackets

Identify the door swinging direction and inspect the door frame header to determine if bracket is required. L- brackets , LZ brackets or U-brackets may be required for the electromagnet depending on the frame header and swinging direction.

  • Put the pin into the Armature
  • awcoding to the picture add the washers on the Armature.
  • Plase Washers between Armature Plate and Door Leaf
  • Use Allen Key to remove the Mounting Plate from lock bodyFERUERW-HWP-N280-Electric-Magnetic-Lock-01 \(2\)
  • Wire go through the wire hole, then screw the mounting plate on top of the door frame
  • Use Allen Key to screw the lock body on the mounting plate
  • Close and pull the door to test holding force, Extra washers can be added to adjust angle between door leaf and Armature plate.
  • Confivm the holding Fovg and tighten the proof Screws.FERUERW-HWP-N280-Electric-Magnetic-Lock-01 \(3\)

FERUERW-HWP-N280-Electric-Magnetic-Lock-01 \(3\)

FERUERW-HWP-N280-Electric-Magnetic-Lock-01 \(4\)

FERUERW-HWP-N280-Electric-Magnetic-Lock-01 \(5\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals