Section 1: Media Loading Instructions
-
Riser Tube
The riser tube should be centered in the bottom of the tank. There is a divet in the bottom of the tank that the basket distributor on the end of the riser tube will fit in. The top of the riser tube should be flush with the very top of the tank. -
GRAVEL MEDIA
Use a piece of tape to cover the riser tube while adding media to the tank. You do not want any media getting into the riser tube. Place the funnel in the opening at the top of the tank. Pour media into the tank using the funnel. -
Granular Activated Carbon
Fill the tank with 4.0 cubic feet of granular activated carbon media. After filling, remove the funnel and tape covering the opening of the riser tube. Clean up the riser, tank threads, and top of the tank before installing the control valve. -
Install Control Valve
Thread the control valve onto the top of the tank. The control should thread on easily. If you feel any abnormal resistance, check to make sure the control is not cross-threaded. The system is now assembled and ready for installation.
Section 2: Valve & Bypass Components
The valve and bypass components are essential for controlling the flow of water through the system. Please refer to the product manual for detailed instructions on installing and operating these components.
Section 3: Plumbing Connection & Startup
-
Connect Plumbing
Connect plumbing to the system with the bypass knobs in the bypass position (perpendicular to the plumbing). Turn on the water to the house and check all connections for leaks. -
Initiate Backwash Cycle
Initiate the backwash cycle on the filter valve. On a digital valve, press the diamond-shaped button on the face of the valve. On a mechanical valve, turn the dial clockwise to the first position. -
Fill Tank with Water
Once the valve is in the backwash mode, open the bypass handles halfway and allow the tank to fill with water. -
Open Bypass Valves
Open the bypass valves all the way once water begins to flow through the drain tube. -
Complete Backwash & Regeneration Cycles
Allow the system to complete the backwash and regeneration cycles on its own. It will return to service once this is done.
Note: The system should be ready for use once the backwash cycle is complete. You may have to initiate a second backwash cycle on very large systems if there is a discoloration to the water. It is normal to see very small air bubbles in the water when new systems are installed. These tiny bubbles can give the water a greyish cast. However, they do quickly dissipate in a clear glass. These bubbles will go away once the system becomes thoroughly saturated. This could take several days depending upon water usage.
Frequently Asked Questions (FAQ)
Q: How much granular activated carbon media should I use?
A: Fill the tank with 4.0 cubic feet of granular activated carbon media.
Q: How do I install the control valve?
A: Thread the control valve onto the top of the tank, ensuring it is not cross-threaded.
Q: How do I initiate the backwash cycle?
A: On a digital valve, press the diamond-shaped button. On a mechanical valve, turn the dial clockwise to the first position.
Q: When should I open the bypass valves?
A: Open the bypass valves all the way once water begins to flow through the drain tube.