Product Information

Specifications

  • Model: IP-A1MP
  • Integration: Microphone, call button, and indicator light
  • Mounting Options: Flush mount or wall mount
  • Compatible with: IP Audio Series

[Front]

  • Status indicator (green)
  • Microphone
  • Call button

[Rear]

  • Wall surface
  • IP-A1MP Microphone panel Plate mounting screw
  • Terminals
  • Control output
  • Plate (Accessory)
  • Machine screw M4 x 35 (Accessory)
  • Wall mount Box YC-802 (Option)
  • Control input
  • Microphone output
  • Microphone volume control

Unit Mounting

Flush mount

  • Plate (Accessory)
  • Machine screw M4 x 35 (Accessory)
  • Flush mount Box YC-801 (Option)

Wall mount

  • Plate (Accessory)
  • Machine screw M4 x 35 (Accessory)
  • Wall mount Box YC-802 (Option)

Product Usage Instructions

Installation

  1. Choose the desired mounting option: flush mount or wall mount.
  2. If flush mounting, attach the plate using the provided machine screw M4 x 35.
  3. If wall mounting, attach the plate using the provided machine screw M4 x 35.
  4. If using a flush mount, optionally install the flush mount Box YC-801.
  5. If using a wall mount, optionally install the wall mount Box YC-802.

Connection

Connect the terminals of the IP-A1MP Microphone Panel as per your requirements.

FAQ

  • Where can I find the specifications of this product?
  • The specifications of this product can be found in the TOA DATA Library. Scan the QR Code provided or visit the TOA website and search for the product number (IP-A1MP).
  • What can I use the Microphone Panel for?
  • The Microphone Panel can be used for conversations or public address announcements when used together with the IP Audio Series.

Thank you for purchasing TOA’s Microphone Panel.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

SAFETY PRECAUTIONS

  • Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.
  • Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety.
  • After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage that could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.

WARNING

  • Indicates a potentially hazardous situation that, if mishandled, could result in death or serious personal injury.

CAUTION

  • Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.

WARNING
When Installing the Unit

  • Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.
  • Install the unit only in a location that can structurally support the weight of the unit and the mounting bracket. Doing otherwise may result in the unit falling and causing personal injury and/or property damage.
  • Since the unit is designed for indoor use, do not install it outdoors. If installed outdoors, the aging of parts causes the unit to fall off, resulting in personal injury. Also, when it gets wet with rain, there is a danger of electric shock.
  • Do not mount the unit in locations exposed to constant vibration. The mounting bracket can be damaged by excessive vibration, potentially causing the unit to fall, which could result in personal injury.
  • Use screws that are appropriate for the wall’s structure and composition. Failure to do so may cause the unit to fall, resulting in material damage and possible personal injury.
  • Use the specified plate in combination. Doing otherwise may cause the unit or component to fall off, resulting in personal injury.
  • Take care that electrical lines are not pinched during installation. Pinched wires could potentially cause a fire or electrical shock.

CAUTION
When Installing the Unit

  • Avoid installing the unit in humid or dusty locations, in locations exposed to direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock.
  • Avoid touching the unit’s sharp metal edge to prevent injury.

SUMMARY AND FEATURES

  • The IP-A1MP Microphone Panel integrates a microphone, a call button and an indicator light. It can be installed in the optional mount box and can be mounted either embedded under a cover or left exposed.
  • When used together with the IP Audio Series, the Microphone Panel can be used as a microphone for conversations or public address announcements.

NOMENCLATURE AND FUNCTIONS

TOA-IP-A1MP-Microphone-Panel-FIG-1

  • The Microphone Panel is powered by a phantom power supply (9 – 26 V DC).
  • Audio from the microphone is output at line signal level and can be adjusted by the microphone volume control.
  • The status indicator is linked to the control input and lights green.
  • Control output is linked to the Call button (momentary operation).

CONNECTIONS

TOA-IP-A1MP-Microphone-Panel-FIG-2

  • Power is supplied to the unit by a phantom power supply (9 – 26 V DC). Before connecting the unit to the IP-A1AF, be sure that the Interface’s DIP switch is set as shown in the figure above.

UNIT MOUNTING

[Flush mount]

TOA-IP-A1MP-Microphone-Panel-FIG-3

[Wall mount]

TOA-IP-A1MP-Microphone-Panel-FIG-4

SPECIFICATIONS

  • The specifications of this product are available in the TOA DATA Library (https://www.toa-products.com/international/).
  • Scan the QR Code at right with your mobile phone camera to access the WEB site and search for this product number (IP-A1MP).

Accessories

  • Plate …………………………………………………………………. 1
  • Plate mounting screw (Preinstalled on the plate) …….. 2
  • Machine screw M4 x 35 ……………………………………….. 2

Optional products

  • Flush mount Box: YC-801
  • Wall mount Box: YC-802

https://www.toa-global.com/en.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals