5 GHz airMAX® AC CPE with
Wi-Fi Management Radio
Model: NS-5AC
QUICK START GUIDE
Introduction
Thank you for purchasing the Ubiquiti Networks® NanoStation® AC. This Quick Start Guide is designed to guide you through installation and also includes warranty terms.
Package Contents
TERMS OF USE: Ubiquiti radio devices must be professionally installed. Shielded Ethernet cable and earth grounding must be used as conditions of product warranty. TOUGHCable™ is designed for outdoor installations. It is the professional installer’s responsibility to follow local country regulations, including operation within legal frequency channels, output power, and Dynamic Frequency Selection (DFS) requirements.
Installation Requirements
-
Phillips screwdriver for wall-mounting
-
Shielded Category 5 (or above) cabling with drain wire should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE.
We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti Networks. For more details, visit www.ubnt.com/toughcable -
Surge protection should be used for all outdoor installations.
We recommend that you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation and the other at the entry point to the building. The ETH-SP will absorb power surges and safely discharge them into the ground.
Diagram Showing Use of Ethernet Surge Protectors
Hardware Overview
Side View
LED Panel
Power The Power LED will light blue when the device is connected to a power source.
Main
Main Ethernet The LED will light steady blue when an active Ethernet
connection is made to the Main/LAN port and flash when there is activity.
Secondary
Secondary Ethernet The LED will light steady blue when an active Ethernet
connection is made to the Secondary port and flash when there is activity.
Signal In airOS®, you can modify the threshold value for the wireless
signal strength LEDs on the Wireless tab under Signal LED Thresholds. The LED
will light when the wireless signal strength is equal to or greater than the
LED’s threshold value.
The default threshold values for these LEDs are shown below:
Ports
Secondary 10/100/1000 Ethernet port used for bridging and supports
software-configurable PoE passthrough.
Main 10/100/1000 Ethernet port used to connect the power and should be
connected to the LAN and DHCP server.
Reset Button To reset to factory defaults, press and hold the Reset
button for more than 10 seconds while the NanoStation is powered on.
Hardware Installation
- Press the Port Cover Release Button located on the back of the NanoStation and slide the cover off.
- Connect an Ethernet cable to the Main port.
- Replace the port cover.
Pole Mount
- Position the NanoStation at the desired location on a pole, aligning its front toward the other end of the wireless link. Insert the Zip Tie into the slot of the Mounting Bracket and tighten around the pole.
- Insert the second Zip Tie into the remaining slot of the Mounting Bracket and tighten around the pole for added security.
Wall Mount
The included Wall Mount Bracket allows the NanoStation to be mounted on a
wall or flat surface using the Screws that came with the NanoStation.
- Secure the Wall Mount Bracket to the wall using the two Screws. Depending on the type of wall material, you may use the included Screw Anchors for additional stability.
- Attach the NanoStation to the wall by aligning it with the Wall Mount Bracket and sliding the Mounting Bracket down into the slot of the bracket until it is secure.
Connecting Power
Connect the power using one of the following options:
- Using the included Gigabit PoE Adapter: Go to Connecting to the PoE Adapter.
- Using a separate PoE switch: Connect the Ethernet cable from the device’s Main port to a PoE-enabled Ethernet port on the switch.
WARNING: The switch port must comply with the power specifications listed in the Specifications section of this Quick Start Guide.
Connecting to the PoE Adapter
- Connect the Ethernet cable from the device to the POE port of the PoE Adapter.
- Connect an Ethernet cable from your LAN to the LAN port of the PoE Adapter.
- Connect the Power Cord to the adapter’s power port. Connect the other end of the Power Cord to a power outlet.
Mounting the PoE Adapter (Optional)
- Remove the PoE Mounting Bracket from the adapter, place the bracket at the desired location, and mark the two holes.
- Pre-drill the holes if necessary, and secure the bracket using two fasteners (not included).
- Align the adapter’s slots with the tabs of the PoE Mounting Bracket, and then slide the adapter down.
Accessing airOS via Wi-Fi
Verify connectivity in the airOS Configuration Interface. There are two
methods, the UNMS™ app and Web Portal. Both are available for 15 minutes
immediately after you power on the NanoStation. If necessary, you can power
cycle the NanoStation to re-enable its Wi-Fi.
Proceed to the appropriate instructions:
UNMS App
-
Download the UNMS app from the App Store® (iOS) or Google Play™ (Android).
-
Connect your device’s Wi-Fi to the NanoStation SSID named: NS-5AC:
Note: Ensure that DHCP is enabled on your Wi‑Fi adapter. -
Launch the app.
-
Tap the NanoStation on the Connections screen.
-
Tap Connect on the Login screen.
-
Select your Country and tap Done.
-
Customize your settings as needed.
Web Portal
-
Connect your device’s Wi-Fi to the NanoStation SSID named: NS-5AC:
Note: Ensure that your Wi-Fi connection has DHCP enabled. -
Launch a web browser and go to: http://setup.ubnt.com
-
Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Login.
Note: The Country setting for U.S. product versions is restricted to a
choice of Canada, Puerto Rico, or the U.S. to ensure compliance with FCC/IC
regulations.
The airOS Configuration Interface will appear, allowing you to customize your
settings as needed. For additional details on the airOS Configuration
Interface, refer to the User Guide available at
www.ubnt.com/download/airmax
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements.
The Output Power field is provided to the professional installer to assist in meeting regulatory requirements.
Specifications
NS-5AC
Dimensions
With Mount
Without Mount| 257 x 84 x 30 mm
(10.12 x 3.31 x 1.18″)
257 x 84 x 41 mm
(10.12 x 3.31 x 1.61″)
---|---
Weight| 233 g (8.22 oz)
Gain| 16 dBi
Max. Power Consumption| 9W
Networking Interface| (2) 10/100/1000 Ethernet Ports
LEDs| Power, ETH1, ETH2, (4) Signal Strength
Power Supply| 24VDC, 0.5A Gigabit PoE Adapter
Power Method| 802.3af or Passive PoE (Pairs 4, 5+; 7, 8 Return)
Supported Voltage Range| 24V ±10%
Mounting| Pole and Wall Mounting Kits Included
ESD/EMP Protection| ±24 kV Contact/Air
Operating Temperature| -40 to 70° C (-40 to 158° F)
Operating Humidity| 5 to 95% Noncondensing
Certifications| CE, FCC, IC
Operating Frequency (MHz)
Worldwide | 5150 – 5875 |
---|---|
US/CA | U-NII-1 5150 – 5250 |
U-NII-3 5725 – 5850
Management Radio (MHz)
Worldwide | 2412 – 2472 |
---|---|
US/CA | 2412 – 2462 |
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in a location that can be submerged by
water.
WARNING: Avoid using this product during an electrical storm. There may be
a remote risk of electric shock from lightning.
Electrical Safety Information
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
www.ubnt.com/support/warranty/
The limited warranty requires the use of arbitration to resolve disputes on an
individual basis, and, where applicable, specify arbitration instead of jury
trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operations of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This radio transmitter (FCC ID: SWX-NS5AC) has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This radio transmitter (IC: 6545A-NS5AC) has been approved by ISED Canada.
RF Exposure Warning
The antennas used for this transmitter must be installed to provide a
separation distance of at least 33 cm from all persons and must not be located
or operating in conjunction with any other antenna or transmitter.
Australia and New Zealand
Warning: This is a Class A product. In a domestic environment this product
may cause radio interference in which case the user may be required to take
adequate measures.
CE Marking
CE marking on this product represents the product is in compliance with all
directives that are applicable to it.
Country List
AT | BE | BG | CY | CZ | DE | DK | EE | EL | ES | FI | FR | HR | HU |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IE | IT | LV | LT | LU | MT | NL | PL | PT | RO | SE | SI | SK | UK |
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the
5150 – 5350 MHz frequency range within all member states.
Note: All countries listed may operate at 30 dBm. BFWA member states may
operate at 36 dBm.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA
member states. Other countries listed may use the 5.8 GHz frequency band.
RoHS/WEEE Compliance Statement
European Directive 2012/19/EU requires that the equipment bearing this
symbol on the product and/or its packaging must not be disposed of with
unsorted municipal waste. The symbol indicates that this product should be
disposed of separately from regular household waste streams. It is your
responsibility to dispose of this and other electric and electronic equipment
via designated collection facilities appointed by the government or local
authorities. Correct disposal and recycling will help prevent potential
negative consequences to the environment and human health. For more detailed
information about the disposal of your old equipment, please contact your
local authorities, waste disposal service, or the shop where you purchased the
product.
Declaration of Conformity
Hereby, UBIQUITI NETWORKS declares that the radio equipment type NS-5AC is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.ubnt.com/compliance
Online Resources
Website www.ubnt.com
Support help.ubnt.com
Community community.ubnt.com
Downloads downloads.ubnt.com
© 2017‑2018 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, the Ubiquiti U logo, the Ubiquiti beam logo, airMAX, airOS, NanoStation, and UNMS are trademarks or registered trademarks of Ubiquiti Networks, Inc. in the United States and in other countries. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Android, Google, Google Play, the Google Play logo and other marks are trademarks of Google LLC. All other trademarks are the property of their respective owners.
NBJL100218
Ubiquiti Networks, Inc.
685 Third Avenue, 27th Floor
New York, NY 10017
USA
References
- community.ubnt.com
- UniFi - Rethinking IT - Ubiquiti
- UniFi - Introduction - Ubiquiti
- Ubiquiti - Compliance
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
- UniFi - Introduction - Ubiquiti
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>