UBIQUITI NETWORKS US-8-60W UniFi 8-Port Gigabit PoE Compliant Managed Switch User Guide
- June 4, 2024
- UBIQUITI NETWORKS
Table of Contents
- UBIQUITI NETWORKS US-8-60W UniFi 8-Port Gigabit PoE Compliant Managed
- Package Contents
- System Requirements
- Hardware Overview
- Top Panel
- Back Panel
- Hardware Installation
- US-8-60W Quick Start Guide
- Grounding (Recommended)
- Connecting Power
- Connecting Ethernet
- Specifications
- Safety Notices
- Limited Warranty
- Compliance FCC
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UBIQUITI NETWORKS US-8-60W UniFi 8-Port Gigabit PoE Compliant Managed
Switch User Guide
Package Contents
- UniFi Switch
- Mounting Screws (Qty. 2)
- Screw Anchors (Qty. 2)
- Power Adapter
- Power Cord
System Requirements
Linux, Mac OS X, or Microsoft Windows 7/8/10 Java Runtime Environment 1.8 or above recommended Web Browser: Google Chrome (Other browsers may have limited functionality) UniFi Controller software v5.3.x (or newer), available at: ui.com/download/unifi
IMPORTANT :
We strongly recommend using UPS backup and power regulation to prevent
equipment damage due to stability issues with local AC power.
Hardware Overview
Front Panel
System LED
Click here for detailed
descriptions.
RJ45 (Ports 1 – 4)
RJ45 ports support 10/100/1000 Ethernet connections.
RJ45 (Ports 5 – 8)
RJ45 ports support 10/100/1000 Ethernet connections and auto-sensing 802.3af
PoE.
Top Panel
PoE LED (Ports 5 – 8)
Off| PoE Off
Back Panel
Ground
Optional ancillary grounding point.
Power
Connect the included Power Adapter to the Power port.
Reset Button
This button serves two functions for the UniFi Switch: Restart Press and
release the Reset button quickly.
Restore to Factory Default Settings Press and hold the Reset button for more than
five seconds.
Hardware Installation
Wall Mounting (Optional)
US-8-60W Quick Start Guide
US-8-60W Quick Start Guide
US-8-60W Quick Start Guide
US-8-60W Quick Start Guide
Grounding (Recommended)
The UniFi Switch is grounded through the Power Adapter however, you can enhance ESD protection by connecting the ancillary ground.
- Loosen the ground screw and secure a ground wire (not included) to the grounding point.
US-8-60W Quick Start Guide
- Secure the other end of the ground wire to a grounding block or other grounded structure.
Connecting Power
Connecting Ethernet
Software Installation
Download and install the latest version of the UniFi Controller software at
ui.com/download/unifi and follow the on-screen
instructions.
Note: If you already have UniFi Controller v5.3.x or higher installed, go
to the section, Adopting the UniFi Switch. After you have installed the
software and run the UniFi Installation Wizard, a login screen will appear for
the UniFi Controller management interface. Enter the username and password
that you created and click Sign In
US-8-60W Quick Start Guide
.
You can manage your network and view network statistics using the UniFi Controller management interface. To adopt the UniFi Switch, proceed to the section, Adopting the UniFi Switch. For information on configuring and using the UniFi Controller software, refer to the User Guide on the website: ui.com/download/unifi Adopting the UniFi Switch
- From the UniFi Controller dashboard, click Devices in the left menu bar.
US-8-60W Quick Start Guide
- Locate the UniFi Switch in the list of devices under the Model column. Click Adopt
The System LED on the UniFi Switch will turn blue to confirm that it has been successfully adopted.
Specifications
US-8-60W
| (5.83 x 3.92 x 1.21″)
---|---
Weight| 432 g (15.24 oz)
Networking Interfaces| (8) 10/100/1000 Mbps RJ45 Ports
PoE Interfaces| (4) Ports 5, 6, 7, 8: IEEE 802.3af
Power Method| 48VDC, Max. 2A
Power Supply| External AC/DC Adapter: 100-240VAC, 50/60 Hz; 48V,
1.25A
Max. Power Consumption| 12W (Excluding PoE Output)
Max. PoE Wattage per Port| 15.4W
PoE Output (Ports 5 to 8)| IEEE 802.3af 2-Pair (Pins 1, 2+; 3, 6-)
Line Rate| 8 Gbps, Non-Blocking
LEDs
System
RJ45 Data Ports
|
Status PoE; Link/Speed/Activity
ESD/EMP Protection| ± 24kV Air, ± 24kV Contact
Operating Temperature| -5 to 45° C (23 to 113° F)
Operating Humidity| 5 to 95% Noncondensing
Certifications| CE, FCC, IC
Safety Notices
- Read, follow, and keep these instructions.
- Heed all warnings.
- Only use attachments/accessories specified by the manufacturer.
- WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.
- WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
- WARNING: Do not use this product in location that can be submerged by water.
- WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
- Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result IN improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
- There are no operator serviceable parts inside this equipment. Service should be provided only by qualified service technician.
- This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
- Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
- The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
- Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
- Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
- Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used IN accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
References
- Ubiquiti - Downloads
- Ubiquiti - Warranty
- community.ubnt.com/
- WEEE Compliance Statement
- US-8-60W Quick Start Guide
- Software Downloads - Ubiquiti
- UniFi - Rethinking IT - Ubiquiti
- Ubiquiti - Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>