GE APPLIANCES AWCS06 Air Conditioner Owner’s Manual
- June 17, 2024
- GE Appliances
Table of Contents
GE APPLIANCES AWCS06 Air Conditioner
THANK YOU!
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too. Among other things, registration of your appliance ensures that we can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration card included in the packing material.
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
- Use this appliance only for its intended purpose as described in this Owner’s Manual.
- This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
- Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
- Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
- Turn the unit OFF and unplug your air conditioner before cleaning.
- For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
Risk of Fire or Explosion. This unit contains flammable refrigerant. Additional safety precautions must be followed.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
- Keep ventilation openings clear of obstruction.
- When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing.
- Do not drill holes in the unit.
- Maintenance, cleaning, and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
- GE Appliances does not support any servicing of the air conditioner. ·
- Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner
READ AND SAVE THESE INSTRUCTIONS
USE OF EXTENSION CORDS RISK OF FIRE. Could cause serious injury or death.
- DO NOT use an extension cord with this Window Air Conditioner.
- DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety; this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should -always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated Wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
Controls
Features and appearance will vary.
Lights below the touch pads on the air conditioner control panel indicate the
selected settings.
Air Conditioner Controls
Remote Control
Controls
-
Power Pad
Turns air conditioner on and off. When turned on, the display will show the Set temperature. -
Display
Shows the Set temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Eco modes. -
Temp and Delay Increase + /Decrease – Pads
Use to set temperature or delay time. Temperature can ce set in Cool and Eco mode. -
Mode Pad
Use to set the air conditioner to Fan Ohl. y, Cool, or Eco mode. -
Fan Speed Pad
In Cool, Eco mode: Use to set the fan speed to Auto, High, Med or Low on the Unit.
In Fan Only mode: Use to set the fan speed to High, Med, or Low on the unit. -
Delay Pad
Delay ON-When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and film settings.
Delay OFF-When the air conditioner is on,
it can ceset to automatically turn off in 1 to 24 hours.
How to set:
Press the Delay 1-24hr pad on the unit or the remote. control Each touch of the Increase + I Decrease – pads on the unit or the remote control will set the timer in 1-hour intervals.
To review the remaining time on the Delay 1-24hr timer, press the Delay 1-24hr pad on the unit or the remote control. Use the Increase + I Decrease – pads on the unit or on the remote control to set a new time if desired.
To cancel the timer, press Decrease – pad on the unit or the remote control until the set time is zero.
After 3 seconds the light on the Delay 1-24 hour pad goes off. -
Filter Reset Pad
This feature automatically notifies you that the air filter must be cleaned. The indicator light will come on after 250 hours of operation. Clean the air filter (refer to page 8), place it back in the front panel, and press the Filter Reset pad. The light will go off.
Using the Air Conditioner
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor conditions. In trust not be used when the outdoor temperature is below freezing (32°F).
Remote Control
- To ensure proper operation, aim the remote control at the signal receiver on the air· conditioner.
- The remote control signal has a range of up to 20 feet.
- Make sure nutling is between the air conditioner and the remote control that could block the signal.
- Make sure batteries are fresh and installed correctly as indicated on the remote control.
Cool Mode
Use the Cool mode at Low, Med, High or Speed for cooling. Use the Temperature Increase+/ Decrease – pads to set the desired temperature between 64°F and 86°F in 1 °F increments.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become. cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting; it may take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling – Select the Cool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling- Select the Cool mode and High fan with a lower set
temperature·.
For Quieter and Nighttime Cooling- Select the Cool mode and Low fan with
a middle set temperature.
Eco
Controls the fan.
ON- The fan will cycle on and off with the compressor.
This may result in wider variations of room temperature and humidity. NOTE:
the fan may continue to run for a short time or may pulse intermittently after
the compressor cycles off to sample the room air.
OFF- The fan runs all the time, while the compressor cycles on and off.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
Auto Fan Speed
Set to Auto for the fan speed to automatically set to the speed needed to
provide optimum comfort settings Vvith the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If
the room Ii e eds less cooling, the fan speed I/viii automatically decrease .
Air Direction
U$e the lever to adjust the air direction left to right.
Care and Cleaning
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before
cleaning.
To clean, use water and a mild detergent. Do not use bleach or -abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least
every 30 days or more often if
necessary.
To remove:
Slide the filter from the left side of the unit Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
DO NOT operate the air conditioner without .a filter because dirt and I int
will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked
regularly. If they are clogged with dirt or soot, they may be professionally
cleaned.
How to Insert the Batteries in the Remote Control
- Remove the battery cover by sliding it according to the arrow direction.
- Insert new batteries, making sure that the(+) and(-) of battery are installed correctly.
- Reattach the cover by sliding it back into position.
NOTES:
- Use 2 “AM” (1 .5 volt) batteries. Do not use rechargeable batteries.
- Remove the batteries from the remote control if the system is not going to be used for a long time.
- Do not mix old and new batteries, Do not mix standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.
Installation Instructions
Questions? Visit our Website at:GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
- IMPORTANT – Save these instructions for local inspector’s use.
- IMPORTANT – Observe all governing codes and ordinances.
- Note to Installer – Be sure to leave these Instructions with the Consumer.
- Note to Consumer – Keep these instructions for future reference. ·
- Skill level – Installation of this appliance requires basic mechanical skills.
- Completion time – Approximately 1 hour
- We recommend that two people install this product
- Proper installation is the responsibility of the installer.
- Product failure due to improper installation is not covered under the Warranty.
- You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC, ‘-.i) 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Do not, under any circumstances, cut or remove the third (ground) prong from
the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems-consult a qualified electrician.
Power cord’ includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of ~he air conditioner and contact a qualified service technician.
TOOLS YOU WILL NEED
-
Phillips head screwdriver
-
Drill and 1/8″ drill bit
-
Pencil
-
Ruler or tape measure
-
Level
-
Scissors or knife
PARTS INCLUDED (Appearance may vary)
-
WINDOW REQUIREMENTS
- These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
- The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window. See the window opening dimensions.
- All supporting parts must be secured to firm wood, masonry or metal.
- The electrical outlet must be within reach of the power cord.
- Follow the dimensions in the table and illustration for your model.
-
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2″
LENGTH: Long enough to fit inside the window frame.
THICKNESS: To determine the thickness, place a piece of wood on the si.11 to make it 1 /2″ higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
-
PREPARE THE AIR CONDITIONER
A. Install the top mounting rail with Type A screws from the outside of the case.
B. Slide the side curtain panels into the side panel rails.
C. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.
-
INSTALL THE AIR CONDITIONER IN THE WINDOW
A. Mark the center of the window. Set the air conditioner in the window so that is it centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
B. Bring the window down so that the front edge of the top mounting is in front of the window. Make sure that the air conditioner is level or tilting slightly to the outside.
C. Extend the curtain panels until they fill the window. Mark the location of the holes in each corner. Use the drill and 1/8″ drill bit to drill pilot holes. Use 4 type B screws to secure the side panels in place.
-
SECURE AIR CONDITIONER
A. Install the side bracket into the unit and into the window sill using two 1″ wood screws provided . repeated on other side.
-
INSTALL WINDOW LOCK BRACKET AND FOAM TOP WINDOW GASKET
Use Type B Screw to install the window lock bracket on top of the bottom window.
A. To prevent broken glass or damage to windows, on vinyl or other
similarly constructed windows, attach the window locking bracket to the window
side jamb with one Type B screw.
B. Cut the foam top window gasket to the window width.
C. Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
Troubleshooting Tips
Save time and Ronny! Review the charts on the following pages first and you may not need to call for service.
Problem | Possible Cause | What To Do |
---|---|---|
Air conditioner does not start . | The unit is unplugged. | Make |
sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circu i t breaker is tripped.| Check the house
fuse/circuit breaker box and replace the fuse or reset the breaker .
Power Failure .| The unit will automatically restart in the setting
last used after the power is restored .
There is a protective time delay (approximately 3 minutes) to prevent tripping
of the compressor overload. For this reason, the unit may not start normal
cooling for 3 minutes after it is turned back on.
The current interrupter device is tripped.| Press RESET button located
on the power cord plug.
If the RESET button will not stay engaged, discontinue use of the air
conditioner and contact a qualified service technician.
Air conditioner does not cool as i,t should.| Indoor airflow is
restricted.| Make sure there are not curtains, blinds or furniture blocking
the front of the air conditioner .
The temp control may not be set properly.| Turn the temperature control
to a higher number.
The air filter is dirty .| Clean the filter at least every 30 days.
See Care and Cleaning section.
The room may have been hot.| When the air conditioner is first turned
on, you need to allow time for the room to cool down.
Cold air is escaping.| Check for open furnace registers and cold air
returns .
Cooling coils have iced up.| See “Air conditioner freezing up” below.
Air conditioner freezing up| Ice blocks the air flow and stops the air
condit i oner from cooling the room.| Set the mode control to High
Fan or High Cool with the temperature setting as high as it can be set.
Water drips outside| Hot, humid weather.| This is normal.
Water . drips inside| The air conditioner is not tilted to the
outside.| For proper disposal, make sure the air conditioner slants
slightly from the case front to the rear .
Water collects in base pan| Moisture removed from air and drain into
base pan .| This is normal for a short period in areas with little
humidity; normal for a longer period in very humid areas.
Normal Operating Sounds
- You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
- You may hear the thermostat click when the compressor cycles on and off.
- Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
- The fan may run even when the compressor does not.
- Water droplets being thrown against the outside coils can make a pinging noise. This helps cool the condenser, You can reduce this noise by removing the subbase water plug.
To ensure maximum efficiency it is recommended to check to ensure the rubber drain plug is properly inserted, This plug may be removed during operation to minimize water in the back of the unit; however, removing it will lower the efficiency of your unit.
NOTE: Do not drill hole in the base pan.
Limited Warranty
GE Appliances Air Conditioner Limited Warranty
For The Period Of: | WilI Replace: |
---|---|
One Year From the date of the original purchase | **Replacement, repair, or |
refund** of the original retail price for any product which fails due to a defect in materials or workmanship. If the unit is exchanged, the replacement unit is warranted for the remainder of your product’s original one-year warranty period. GE Appliances will, at its sole discretion, replace the product with a product of the same or comparable functionality and quality or refund the original retail price.
In Order to Make a Warranty Claim During Your Retailer’s Allowable Return Period:
- Properly pack your unit. We recommend using the original carton and packing materials.
- Return the product to the retail location where it was purchased.
- Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect.
ln Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
- Locate your original sales receipt and make a note of your model and serial number.
- Call 866.907.1655 (in the United States) to initiate a warranty claim.
- You will be asked to provide your name, address, date of purchase, model and serial number
- Warrant cairns may require electronic or mailed-in evidence of purchase
What Will Not Cover:
- Customer instruction. This owner’s manual provides information regarding operating instructions and user controls.
- Improper installation. If you have an installation problem, or if the product is of improper capacity, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
- Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
- Replacement of house fuses or resetting of circuit breakers.
- Failure due to corrosion.
- Derange to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
- Incidental or consequential derange caused by possible defects with this product.
- Derange caused after delivery.
EXCLUSION OF IMPLIED WARRANTIES – Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
For US Customers: This limited Warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available; you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state, To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor US:
GE Appliances, a Haier company
Louisville, KY 40225
Consumer Support
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliance’s
Website 24 hours a day, any day of the year! You can also shop for more great
GE Appliances products and take advantage of all our online support services
designed for your convenience. In the US:
GEAppliances.com
Register Your Appliance
Register your new appliance online at your convenience! Timely product
registration will allow for enhanced communication and prompt service under
the terms of your warranty, should the need arise: You may also mail in the
pre-printed’ registration card included in the packing material. In the US:
GEAppliances.com/register
Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted) . Order online today 24 hours every day.
In the US: GEApplianceparts.com or by phone at 877.959.8688 during normal business hours. Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe. operation.
Contact Us
If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the details including your phone number, or write to: In the US: General Manager, Customer Relations I GE Appliances, Appliance Parkin Louisville, KY 40225 GEAppliances.com/contact
References
- Appliance Parts, Accessories & Water Filters | GE Appliances
- Contact Us or Get Help with Questions | GE Appliances
- GEAppliances.com/register
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>