- June 17, 2024
- SENTINEL
Table of Contents
MBA0103 Articulated Arms Automation Kit For Swing Gate
OpenGate 2
MBAO103
pour portail battant
Articulated arms automation kit for swing gate
SAFETY INSTRUCTIONS
WARNING: Important safety instructions. It is essential to follow these
instructions for reasons of personal safety. Keep these instructions in a safe
place.
WARNING: Important safety instructions. Follow all instructions carefully
as improper installation may result in serious injury.
This product is only designed for the automation of a swing gate for
«residential» use.
The power supply installation must comply with current standards in the
country where the product is installed (NF C 15-100 for France) and be carried
out by qualified staff. A means of disconnecting all the poles of the supply
network must be provided. This device must be connected directly to the supply
terminals and have a contact separation distance on all poles to ensure
complete disconnection in accordance with the installation rules.
The mains supply must be protected against overload by a suitable trip switch
and an earth leakage circuit breaker.
CAUTION: The motorised system must be disconnected from its power source
during installation, cleaning, maintenance and parts replacement.
Installation requires qualified staff with mechanical and electrical skills.
– Make sure that the temperature range indicated on the motorised device is
suitable for the installation’s location.
– Only original parts should be used to replace or repair the motorised
system.
– Before installing the motorised device, check that the driven part is in
good mechanical condition, properly balanced and opens and closes correctly.
– The motorised device cannot be used with a driven part incorporating a side
gate.
– Ensure that crushing caused by the opening movement of the driven part is
avoided between the driven part and the surrounding fixed parts.
– After installation, ensure that the mechanism is properly adjusted and that
the protection system and any manual disconnection devices function properly.
– Activation of the manual disconnection device may cause uncontrolled
movement of the driven part due to mechanical failure or loss of balance.
– Frequently examine the installation for imbalance where applicable and signs
of wear or damage to cables, springs and mounting. Do not use if repair or
adjustment is necessary.
– This appliance may be used by children at least 8 years old and by people
with reduced physical, sensory or mental capabilities or without experience or
knowledge, if they are properly supervised or instructed in the safe use of
the appliance, and if the risks involved have been understood. Children should
not play with the appliance.
The user’s cleaning and maintenance must not be carried out by unsupervised
children.
– Do not allow children to play with the unit or its controls, including
remote controls.
– Permanently attach the label for the manual disconnection device to the
operating element of this device.
Only use the remote control when you have a complete view of the gate.
If in any doubt, do not operate the system, as it could be damaged.
SCS SENTINEL certifies that its swing gate operators for residential use
comply with the European standards and safety regulations for swing gate
operators (EN 60335-2-103). The use nfl is product outside the specified
conditions or the use of components or accessories not recommended h¥ SENTINEL
may compromise the safety of property and persons, and is therefore
prohibited. SCS SENTINEL accepts no liability for any damage resulting from
failure to comply with the instructions provided in this manual.
Potential risks
There are 4 potential risks 3 zones identified opposite:Risk 1: Shock and crushing
Prevention :
– Obstacle detection by motor.
– Use of photocells. Risk 2 :
Hand crushing Prevention : migem
– Leave a minimum distance of 10 cm between the leaf and the pillar/wall.
– Notch the corner of the pillar without pillar weakening it. Risk 3 :
Imprisonment and crushing
Prevention :
– Obstacle detection by the motor.
– Leave a minimum distance of 50 cm between the motor arm and the wall (or
other fixed part). Risk 4 :
Crushing of the feet
Prevention :
– To avoid a danger zone for feet, leave a minimum distance of 12 cm or a
maximum of 5 mm between the bottom of the leaves and the floor.
DESCRIPTION
B1- Contents B2- Dimensions
WIRING / INSTALLING
C1- Standard installation
C2- Dimension chart
Comply with the measures shown on the chart for proper installation. Adjust
the gate structure to fit it for best automation, if necessary.
Before starting the installation, please make sure that the gate moves freely
and that :
- Hinges are properly positioned and greased.
- No any obstacle in the moving area.
- No frictions between two gate leafs or and on the ground while moving.
- Enough space is left when the gate is opening.
a. Distance perpendicularly from gate bolt to the front of fixing bracket.
b. Distance from the bolt perpendicular to the surface of articulated arm opener.
c. Distance between the position of arm fixation and the bolt.
d. Installation angle from full closed and full opened position.
Inside opening
Dimension chart
A (mm) | B (mm) | C(mm) | D |
---|---|---|---|
50 | 50 | 600 | 90°- 95° |
50 | 100 | 550 | 90°- 105° |
50 | 150 | 500 | 95°- 110° |
100 | 50 | 630 | 90°-95° |
100 | 100 | 580 | 90°- 100° |
100 | 150 | 530 | 95°- 110° |
150 | 50 | 600 | 90°-95° |
150 | 100 | 550 | 90°- 100° |
150 | 150 | 500 | 95°-110° |
200 | 50 | 600 | 900-950 |
200 | 100 | 550 | 90°-100° |
200 | 150 | 500 | 95°-105° |
COTEA:
minimum 50 mm
maximum 200 mm
COTEB:
minimum 50 mm
maximum 150 mm
C3- Motor fixing
- Refer to the Dimension Chart to choose the correct dimensions of the motors and position.
- Check if the mounting surface of the brackets to be installed is smooth, vertical and rigid.
- Arrange the cables for power supply cable of the motors.
- Motor installation and setting for mechanical stopper in opened and closed position.
Remove the upper cover and mechanical stoppers on the bottom of motor. Install
the motor on the U-shape with screws (n°8) and corresponding nuts. Place the gate in
the full closed position and fix the U-shaped fixing plate on the wall
After positioning
the front of curved arm on the bottom of motor, position the minor arm on the
end of curved arm and mounting bracket with corresponding screws and nuts.
To unlock the arms
refer to paragraph C4
Closed position adjustment : Once the full closed position is decided, fix the
corresponding mechanical stopper in this position. Opened position adjustment : Adjust the gate to full
opened position and once the position is decided, fix with corresponding
mechanical stopper. This
operation must be carried out a second time to install the second arm
C4- Emergency release
- Insert the release key to the release slot
- Turn the release key clockwise
- Release and move the gate
****At the beginning you may notice that the motors are difficult to release.
Do not worry, it will disappear with time. Permanently attach the label for the manual
disconnection device to the operating element of this device.
Position of locked
motor : the pintle should be exited Pasition of unlocked motor : the pintle should be
pressed
TiP
Instead of unlocking a motor with arms strength, you can use a battery
connecting the white and yellow motor cables one way or the other following
the polarity to operate the motors. ** The white and yellow cables must be disconnected
from the electronic card.
C5 – Wiring diagram Inside
opening**
The main and
secondary motors can be installed on the right or on the left pillar.
C6- Installing
Power supply connections
Please kindly notice that the operation of power connection should be carried
out by a qualified electrician with following steps.
Make sure that all your connections (motors, blinker, antenna, photocells,
lock, etc.) are perfectly made before connecting the 230V power supply to the
grey domino.
See diagram (Figure 1- page 24) Wire connection secondary motor Photocells
The photocells are safety devices for control automatic gates. Consist of one
transmitter and one receiver based in waterproof covers; it is triggered while
breaking the path of the beams. If an obstacle is detected, the gate stops and
opens again slightly allowing the obstacle to be released safely. Blinker
Remove any packaging before connecting.
If you want to improve the operating range of your remote, you can connect the
blinker antenna with a RG58 coaxial cable (not supplied). In this case you
must disconnect the original antenna and then connect the coaxial copper core
to the terminal ANT and the coaxial braided shield to the terminal GND on both
antenna and electronic card.
SETTING /USING
D1- Switch settings (dip switch 1) Switch settings: «on» down position, «off» up
position.
DIP SWITCH1:
ON = double gate operation
OFF = single gate operation (connection on and 6)
D2- Power setting (dip switch 2 et 3)
DIP SWITCH (OVER C1) | DIP SWITCH (OVER C2) | CURRENT (AMP) |
---|---|---|
DIP switch 2 OFF | Dip switch 3 OFF | 5A |
DIP switch 2 OFF | Dip switch 3 ON | 4A |
DIP switch 2 ON | Dip switch 3 OFF | 3A |
DIP switch 2 ON | Dip switch 3 ON | 2A |
D3- Gate auto-close adjustment (dip switch 4)
DIP SWITCH 4
«ON »: Active automatic closing in 30 seconds. Simultaneously pressing the two
remotes top keys’ (opened or closed gate) will turn OFF the automatic mode
(the blinker will flash 3 times as confirmation).
Repeat the operation to turn ON the automatic mode (the blinker will flash 3
times as confirmation).
Note :in case of automatic closing, photocells are required
«OFF » : Automatic closing OFF (caution it will still be possible to turn ON
with the remote)
D4- Photocell adjustment (dip switch 5)
DIP SWITCH5:
ON : Photocells ON. When the photocells detect an obstacle while the gate is
closing, the gate stops and opens during 2 seconds.
If the gate auto-close is adjusted, and the photocells detect an obstacle when
the gate is totally opened, then the closing time will be reseted.
OFF : No detection by the photocells, the photocells will not control the
opening of the gate.
D5- Dephasing of the leaves (dip switch 6)
DIP SWITCHG6 :
ON : Dephasing in closing / opening of 8 seconds.
OFF : Dephasing in closing / opening of 3 seconds.
D6- Decelaration speed
The speed is 70% output of the full speed (no adjustment possible).
D7- LED indication LED 1 RF indicator : radio frequency:
LED1 blinks when remote controls are activated.
LED 2 System learning:
LED 2 blinks twice per seconde during normal operation and once per seconde
during learning. Static LED2 means incorrect programming.
LED 3 Photocells:
LED 3 will be on when photocells are not aligned or when an obstacle is
between the photocells.
LED 4 Start:
LED 4 will be on if the switch of the transmitter, key selector, or the push
button s activated.
D8- Remote controls learning process
Press “RF-learn” button for 2 seconds, and the LED1 will be on; then press the
transmitter top left button.
The LED1 will blink twice and stay on for 10 seconds then be off. And the
remote memorize has completed.
D9- System learning process double gate
****The remote control memory storing operation must be over hefore starting
the final system learning process.
Let your gate totally opened then lock them (part C4)
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-left
key for a double gate.
The system learning process will be as follows, step by step: After step 6, the
system learning process is complete. You can use it with the remote control:
double gate full opening pedestrian opening (single gate)
The LED2 light will remain ON until the system learning process is not over.
Check the wiring connection and repeat the step
D10- System learning process simple gate
Switch 1 OFF.
Totally open the leaf gate.
Press «SYS-learn» (until the LED2 light begins to flash once every second,
instead of twice every second as it normally would), then press the upper-
right key for a single gate.
The system learning process will be as follows, step by step: single gate
opening
TECHNICAL FEATURES
Motor
Motor | 24V DC motor with manual unlocking |
---|---|
Gear type | electromechanical articulated arm |
Supply voltage | 24VDC |
Maximum Gate Weight / Maximum Gate Length | 250 kg /2.5 m per leaf |
Operating Temperature | -20°C~+50°C |
Dimensions | 285 mm x 160 mm x 298 mm |
The A-weighted emitted sound pressure level of the motor is equal or less than
70 dB (A).
Blinker
Antenna included | YES (coaxial cable not supplied) |
---|---|
Bulb | LED E14 24V 1W (included) |
Power cable | 2x 1 mm2 (not included) |
Bulb connection | unpolarized at the electronic card connection. |
Screws | included |
Do not supply 230V | |
Operating temperature | -20°C~+50°C |
Dimensions | 74 x 167 x 59 mm |
Photocells
Detection Method | infrared Beam |
---|---|
Sensing Range | MAX~10 m |
Input Voltage | 12~24V AC/DC |
Response Time | < 100ms |
Operation Indicator | RX: Red LED On (beam broken) / Off (beamaligned) TX : Red |
LED On
Dimensions| 63 x 63 x 30 mm
Output Method| relay Output
Remote controls
Channels | 4 |
---|---|
Frequency – Maximum transmitted power | 433.92 MHz – power < 10 mW |
Power supply | 1 battery lithium CR2032 included |
Security | rolling code technology |
MAINTENANCE
F1- Motor
Conduct the following operations at least every 6 months. If in high intensity
of use, shorten the period in between.
Disconnect the power supply:
- Clean and lubricate the screws, the pins, and the hinge with grease.
- Check the fastening points are properly tightened.
- Make the wire connection are in good condition.
Connect the power supply:
- Check the power adjustments.
- Check the function of the manual release.
- Check the function of photocells or other safety device.
F2- Remote control
F3- Maintenance advice
Ensure the correct operation of safety devices (photocells, flashing light,
etc.)| 1x per season| Clean inside and out with a microfiber
---|---|---
Ensure that the manual clutch works properly| Perform a disengagement, open
and close your gate completely manually (during the disengagement a hard point
can come before manoeuvring manually it remains a normal phenomenon)
Check the electronic safe for oxidation, insects or other damage| 1x per
season| Clean inside and out with a microfiber
Sealing of the electronic box| Check silicone seals + gland
Check the gate| Txyear| lubrication of hinges
TECHNICAL ASSISTANCE
G1- Troubleshooting
Problem | Solutions |
---|---|
Overheated back-up batteries | Check the wiring connection of the batteries. |
The gate doesn’t move when pressing thebutton of the transmitter | 1. Checkif |
LED1 is “ON” once pressing the transmitter.
2.Check if the voltage of the batteries is above 25V.
3. Check if LED2 is “ON” and blinks accordingly.
4. Make sure all the wiring connections are firmly connected to the terminals
on the PCB.
5. Make sure the fuse is workable. on the panel and power socket.
The transmitting distance is too short| Make sure the connecting terminals of
the antenna is firm.
Check the battery on the trasmitter.
The Flashing light does not work| Unscrew and screw in the bulb
Check if the wiring connection of the flashing light is correct.
The leaves suddenly stop during moving The leaves does not move or only move
toward one direction| 1. Check if the gate can be moved freely and no
obstacle is between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the safety beam are operating properly if installed.
4. Cut off the power of the engine. Release the motor and make sure the gate
can move freely.
The master gate closes to the end first and the slave gate stops, which the
opening or closing sequence is not being operated properly| 1. Check if the
gate can be moved freely and no obstacle is between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure the safety beam are operating properly if installed.
5. Cut off the power of the engine. Release the motor and make sure the gate
can move freely.
The gear motors does not run and the relay is noisy when operating the gate
opening and closing| | Check the condition fuse.
No remote control connection| 1. Check LED1 is blinking when pressing the
remote control key.
2. Check RF1 receiver is ok.
3.To check that the remote control is associated when the remote control is
pressed, LED 1 and LED 4 must light up.
4. If the LED flashes for 1 second when the remote control is pressed, the
battery must be changed.
5. Remove and replace the plug-in receiver
4 steps instead of 6 when learning process| Reverse polarity on all motors
G2- Tutos
G3- Free online
Any question?
For an individual answer, use our online chat on our website www.scs-
sentinel.com
WARRANTY
SCS Sentinel grantsto this producta longer warranty period, beyond the legal
e, as a sign of quality and reliablity.
‘The invoice will be required as proof of purchase date. Please keep it during
the warranty period.
Carefully keep the barcode and the proof of purchase, that willbe necessary o
claim warrany.
Are never covered by our warranty:
- Damage resulting from the consequences of a bad installation (bad wiring, reverse polarity …
- Damage resulting from improper use of the device (use in contradiction with the manual) or its modification.
- Damage resulting from the consequences of the use of components not from SCS SENTINEL.
- Damage due to lack of maintenance, physical shock.
- Damage due to weather: hail, lightning, strong wind etc..
- Returns made without a copy of the invoice or receipt.
WARNINGS
Don’t throw batteries or out of order products with the household waste
(garbagel. The dangerous substances that they are likely to include may harm
health or the environment. Make your retailer take — back these products or
use the selective collect of garbage proposed by your city.
Do notingest battery, Chemical Burn Hazard. This product contains a button
cell battery. If the button cell battery is swallowed, it can cause severe
internal buns in just 2 hours and can lead to death. Keep new and used
batteries away from children. If the battery compartment does not close
securely, stop using the product and keep it away from children. If you think
batteries might have been swallowed or placed inside any part of the body,
seek immediate medical attention. Do not clean the remote control with
abrasive or corrosive substances. Use a simple cloth. Do not allow children to
play with the product or packaging.
When replacing the battery, use a battery with the same characteristics as the
one supplied with the product. Remove the batteries from the equipment if it
is not to be used for a prolonged period, except in emergency situations.
Batteries must not be exposed to excessive heat or thrown into a fire.
DECLARATION OF CONFORMITY
SCS Sentinel hereby declares that this product s in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU
and Directive 2006/42/EC.
The Declaration of Conformity can be found at: www.scs-
sentinel.com/downloads
Toutes les infos sur : www.scs-sentinel.com https://www.youtube.com/c/Scs-laboutique
110, rue Pierre-Gilles de Gennes
49300 Cholet – France
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>