EVERTONE EMSWM 4-in-1 Medi Back Belt Instruction Manual

June 17, 2024
Evertone

EVERTONE EMSWM 4-in-1 Medi Back Belt

PRODUCT INTRODUCTION

Caution

  • Never use at the same time as the following kinds of medical electrical devices.
  • Doing So may cause an accident or the medical device to malfunction and result in significant bodily harm.
  • Implanted medical devices, such as pacemakers.
  • Medical electrical equipment is used to sustain life, such as heart-lung machines.
  • Wearable medical devices, such as EKGs.

Anyone with the following conditions should consult a physician before using this product. Not doing so may cause an accident or problems to the body or skin.

  • Persons prone to allergies
  • Patients with severe heart disease
  • Women who are pregnant or have just given birth
  • Persons with a fever(g$Cor above)
  • Patients with malignant tumors
  • People with impaired Limbe
  • Children or unexpressive people
  • Persons who feel anything unusual with their cranial nerves (epilepsy. ete).
  • People with perceptual impairment caused by high-level – peripheral circulatory disorders
  • Persons with an acute (painful) condition, such as spine fracture, sprain, pulled muscle, etc.
  • Persons with an impairment in perception or problems with their skin(inflection inflamed skin or scratches).
  • Persons receiving, treatment from a medical institution
  • Those who are not sensitive to beat or are proven to beat allergies
  • People with sensory or mental impairments

Other matters needing attention

  • This product can only be used on the waist and abdomen, please do not use it on other parts
  • Recommended for people 16 years old and above
  • During the massage, do not make the keys and other metal objects touch the electrode pads, otherwise, you may receive a strong, electric shock
  • Do not use this product in places with high heat, flammability, electromagnetic radiation, and humidity
  • Do not use the same area for a long time, otherwise, it may fatigue the muscles of the massaged area and cause – physical discomfort.

Product structure

EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(1\)

Packing list

  • Device x1 Remote control x1 TYPE-C charging cable x1
  • gel pad x4 Manual x1

Charging method

  • It may prompt that the battery is low when it is used for the first time.
  • Please charge the unit before using it.

Charging time

EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(2\)

Charging method

  • Please use a universal 5V 1A mobile phone charger to charge this device.
  • For environmental protection, this device is not equipped with a charger.
  • After inserting the TYPE-C charging – cable into the charger (make sure the voltage is 5V), then plug the other end of the charging- cable into the charging port of the device.
  • At this time, the charging LED lamp will – flash.
  • When the device is fully charged, the four charging LED lamps will keep bright.

Battery installation of the remote control:

  • The remote control of this machine uses a universal CR2032 button battery.
  • When replacing the battery, open the battery cover, put the battery in the battery compartment, and then cover the battery cover.

Operation guide

  1. Fix the device with straps Please stick the unit on your back, and adjust the wearing height according to your height and physique. After wearing, wrap the fixing strap tightly to fix the device on the body.
  2. Start using
    • Switch machine:
    • Press the device power button to turn on the device, and then press the remote control power button to control the device to start; When shutting down, please press and hold- the device power button, or long press the remote control power button.EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(4\)

Storage and maintenance

  • Do not use the same part continuously for more than 25 minutes to avoid muscle fatigue or low-temperature burns.
  • For healthy use, the machine is set as a working cycle of 15 minutes. After the working cycle is completed, it will automatically shut down; please restart it when you use it again.
  • Be sure to turn off the machine before removing the device from your body.
  • Please clean the electrode pads of the device before storing them properly. Be careful not to bump the electrode pads when storing.
  • Put the machine in the storage bag after cleaning to prevent the electrodes from attaching dust and other dirt.
  • To avoid scratching the electrode pads of the device, please wipe carefully with a soft cloth when cleaning.
  • When cleaning, please take off the device first, put a soft cloth in a neutral detergent (3%-5%) dilated with warm water, soak it, carefully wipe the dirt on the surface, and then dry it.
  • Do not use thinner gasoline, alcohol, etc. for wiping.

Before maintenance, please make sure that the power is turned off. If you perform maintenance while the power is on, you may be irritated by electric shocks.

Q&As

  • Q: Can it be used every day?
    • A: Yes, but it is recommended to use the same part once a day. Please avoid repeated use of the same part, otherwise, it may cause muscle fatigue. In addition, if you feel unwell or have abnormal skin, please stop using it immediately and seek medical attention.
  • Q: Can it be used in the bathroom?
    • A: The product is not waterproof, please avoid using it in the bathroom, otherwise it may cause accidental injuries.
  • Q: Which intensity is more appropriate?
    • A: Please set a lower intensity when you use it for the first time, and adjust the other intensity after adapting to the low intensity.
  • Q: Can the product be used after delivery?
    • A: Yes, but you need to wait at least 6 weeks after delivery. Please consult a doctor before using it. If it is a cesarean section, you need to get the doctor’s permission to use it after 3 months.
  • Q: The skin turns red after use, is this a problem?
    • A: It is a normal phenomenon that the skin becomes red after use. On the one hand, due to the accelerated – flow of blood under the action of the low frequency of the EMS, the skin becomes red. On the other hand, due to the tightening of the belt, the surrounding skin will produce red marks, but don’t worry, these red marks will slowly If the red mark is too deep, please be careful not to tighten the belt too tightly. You can try to choose a low-grade force when using it. If these have not worked, please stop using them and consult a doctor.
  • Q: Will using this product cause muscle soreness?
    • A: Like all exercises, the use of this product will cause various degrees of soreness in the muscles of the application site. This is a normal phenomenon, and it will last for 1-2 days. Please adjust the frequency of use according to your situation.

Specification and disposal methods

EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(5\)

How to take

How to take out the rechargeable battery

  1. The built-in lithium battery of this product contains substances that may pollute the environment. Before discarding this product, the built-in lithium battery should be taken out.
  2. Before disassembling this product and removing the lithium battery, be sure to turn off the power or cut off the power.
  3. The detailed steps for removing the lithium battery are shown in the figure below. After removing the 8 screws on the back, take out the lithium battery.
  4. The taken-out lithium battery should be safely disposed of, and discarded in a place specified by the government or a recycling unit.EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(6\)

Troubleshooting

EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(7\)

If the abnormality persists after the above treatment, please stop using it immediately and contact the sales or local customer service center of the purchased product.

Element of harmful substances in products

EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(8\)

This form is compiled following the provisions of S/T11364-2014-

  • 0: Indicates that the content of the hazardous substance in all homogeneous materials of the part is below the limit requirement specified in GB/T26572.
  • X: Indicates that the content of the hazardous substance in at least one of the homogeneous materials of the part exceeds the limit requirement specified in GB/T 26572.

The “Environmental Protection Use Period” of this product is marked as shown on the left. It is based on the “Administrative Measures on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products” and the “Guiding Opinions of the China Household Electrical Appliances Association on the Environmental Protection Use Period of Household Electrical Appliances” promulgated on July 1, 2016, according to the requirements of the “Administrative Measures  * for product producers and importers the hazardous substance content in the product shall be disclosed per the requirements and format of the relevant supporting standards, and the environmental protection use period of the product shall be marked.

Product inspection certificate

  • This product meets factory standards has passed the inspection Inspectors:
  • Date of manufacture:

Product warranty card

EVERTONE-EMSWM-4-in-1-Medi-Back-Belt-FIG-1 \(9\)

PROVIDE HEALTHY AND PERFECT LIFE FOR YOU

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals