SMARTSAFE iSmartEV OM210 Professional Diagnostic Tool User Manual
- June 17, 2024
- SmartSafe
Table of Contents
iSmartEV OM210 User Manual
Copyright Information
Copyright © 2021 by SHENZHEN SMARTSAFE TECH CO.,LTD. All rights reserved. No
part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise, without the prior written permission of SMARTSAFE.
Neither SMARTSAFE nor its affiliates shall be liable to the purchaser of this
unit or third parties for damages, losses, costs, or expenses incurred by
purchaser or third parties as a result of: Accident, misuse, or abuse of this
unit, or unauthorized modifications, repairs, or alterations to this unit, or
failure to strictly comply with SMARTSAFE operating and maintenance
instructions.
SMARTSAFE shall not be liable for any damages or problems arising from the use
of any options or any consumable products other than those designated as
Original SMARTSAFE Products or SMARTSAFE Approved Products by SMARTSAFE.
All information, specifications and illustrations in this manual are based on
the latest information available at the time of printing. SMARTSAFE reserves
the right to make changes at any time without prior written or oral notice.
Trademark Information
is a registered trademark of SHENZHEN SMARTSAFE TECH CO.,LTD. in China and
other countries. All other SMARTSAFE trademarks, service marks, domain names,
logos, and company names referred to in this manual are either trademarks,
registered trademarks, service marks, domain names, logos, company names of
SMARTSAFE or are otherwise the property of SMARTSAFE or its affiliates. In
countries where any of the SMARTSAFE trademarks, service marks, domain names,
logos and company names are not registered, SMARTSAFE claims other rights
associated with unregistered trademarks, service marks, domain names, logos,
and company names. Other products or company names referred to in this manual
may be trademarks of their respective owners. You may not use any trademark,
service mark, domain name, logo, or company name of SMARTSAFE or any third
party without permission from the owner of the applicable trademark, service
mark, domain name, logo, or company name. You may contact SMARTSAFE by
visiting the website at
www.newsmartsafe.com , or writing to
SHENZHEN SMARTSAFE TECH CO.,LTD., 3310, Building 11, Tianan Cloud Park,
Bantian Street, Longgang District, Shenzhen, Guangdong, China, to request
written permission to use Materials on this manual for purposes or for all
other questions relating to this manual.
To avoid personal injury, property damage, or accidental damage to the
product, please read all the information in this chapter before using the
product.
Safety Warning
Please read the following safety precautions carefully to avoid personal
injury and damage to this product or other connected products. To avoid
possible injury and danger, this product shall only be used within the
specified range.
Be careful when handling equipment.
Do not drop, bend, puncture, insert foreign objects or place heavy objects on
the device, which may damage the internal wearable components.
Avoid fire or personal injury.
Only authorized professional personnel shall perform maintenance.
Connect and disconnect properly.
- Do not unplug when the probe or test end is connected to the voltage source.
- Before connecting the probe to to the circuit under test, please connect it to
the Oscillograph Multimeter. Disconnect the probe from the circuit under test before disconnecting the probe from the test instrument.
Use the correct probe. To avoid excessive current impact, use the correct
rated probe for the measurement.
Avoid circuit exposure. Do not touch any exposed connectors and components
when the power is on.
Do not operate the product when you suspect a malfunction. If you suspect a
product malfunction, have it checked by qualified maintenance personnel.
Keep ventilation.
Keep your product properly ventilated.
Do not operate in a humid environment.
Do not operate in a flammable or explosive environment.
Keep the surface of the product clean and dry.
Do not disassemble or modify the equipment.
The equipment is a sealed unit with no end-user serviceable parts inside. Only
authorized maintenance agency or authorized technicians shall perform internal
repairs. Attempting to disassemble or modify the unit will void the warranty.
Do not attempt to replace the internal battery.
Only authorized maintenance agency or authorized technicians shall replace the
internal rechargeable batteries.
Precautions for operation of automotive ECU.
- After the ignition switch is on, do not disconnect the vehicle’s internal electrical device at will to avoid damage to the ECU or equipment.
- Do not place magnetic objects close to the computer to avoid circuits and components failure in the ECU.
- Before performing welding work on the vehicle, disconnect the ECU system power first.
- When performing repair work close to computers or sensors, special care shall be taken to avoid damaging the ECU and sensors.
- When disassembling and installing programmable read-only memory, the operator shall wear a grounding metal band with one end wrapped around wrist and the other end clipped to the vehicle body, so as to avoid ECU circuit failure caused by static electricity.
- Ground the ECU harness connector reliably to avoid damage to the electronic components such as integrated circuits inside the ECU.
Packing List
The following accessories are for reference only. Please consult from the local agency or check the package list supplied with this tool together.
No. | Name | Q’TY | Reference Picture |
---|---|---|---|
1 | iSmartEV OM210 | 1 | |
2 | Power Adaptor | 1 | |
3 | USB Cable (Type-B) | 1 | |
4 | Oscilloscope Test Clip | 2 | |
5 | Pin Kit | 1 | |
6 | Crocodile Chuck Black | 2 | |
Crocodile Chuck Red | |||
7 | Crocodile Chuck Red | ||
Crocodile Chuck Red | |||
8 | User Manual | 1 | – |
9 | Packing Lis | 1 | – |
Product Introduction
2.1 Overview
iSmartEV OM210 is a new energy test equipment developed by Smart Safe, which
integrates oscilloscope and multimeter functions. The tool needs to be used
together with detection tool (such as iSmartEV P01). The oscilloscope is
mainly used to measure voltage signals and analyze the form of electronic
signals. Automobile repair technicians can quickly judge automobile electronic
equipment and circuit failure by observing the waveform of the whole signal.
Oscilloscope scanning speed is far greater than the frequency of the such
automobile signals, usually 5~10 times of the measured signal. The automobile
oscilloscope can not only capture circuit signals quickly, but also display
these waveforms at a slower speed, so as to observe and analyze at the same
time. It can also store and record the tested signal .waveform, and observe
the fast signal that has occurred through playback, which greatly facilitates
fault analysis. The multimeter mainly measures voltage, current and
resistance. It can judge whether the part is good or not and whether the
circuit is complete by simple measurement.
2.2 Composition
No. | Name | Description |
---|---|---|
1 | Fuse | |
*2 | A | 10A current input terminal |
*3 | mAμA | Milliampere/Microampere (Less than 400ma) current input terminal |
*4 | COM | Negative common terminal |
*5 | V/Ω | Voltage/Resistance and other input terminals |
6 | Handle | |
7 | Power Indicator | Red flashing indicates insufficient power; If the red |
light is normally on, it indicates that charging is in progress; A constant
green light indicates that the battery is normal or fully charged.
8| State Indicator| Green light indicates normal operation.
9| Wireless Indicator| The red flashing indicates that the wireless connection
is in progress; The green light indicates that the wireless connection is
normal.
10| Indicator| Green light indicates normal operation.
11| CH1| Oscilloscope Channel 1
12| CH2| Oscilloscope Channel 2
13| Communication/Charging Jack| 1. When charging, use the power adaptor and
USB cable to charge the Oscillograph Multimeter.
2. When transmitting data, use USB cable to connect the Oscillograph
Multimeter and detection equipment.
Note: The detection equipment cannot supply power to the Oscillograph
Multimeter.
Please charge the Oscillograph Multimeter before use.
14| Power Button| Press and hold this key to turn on/off.
2.3 Technical Parameters
When used as oscilloscope:
Item | Specification Parameters |
---|---|
Number of Channels | 2 |
Bandwidth | 10MHz |
Maximum Real-time | 100Mbps |
Sampling Rate | |
Time Base Range | 1us/div~10s/div, step by 1 ~ 2 ~ 5 times |
Sampling Mode | Common sampling, peak detection, average value |
Storage Depth | 1M |
Input Coupling | DC, AC and Grounding |
Input Impedance | 1MΩ±2% |
Input Capacitance | 20pF (maximum) |
Vertical Sensitivity | 2mV/div~5V/div |
Vertical Resolution | 8bits |
Maximum Input Voltage | 40V peak (DC + AC peak) |
Probe Attenuation Coefficient | 1X, 10X (probe support required) |
Trigger Type | Edge trigger, pulse width trigger |
Trigger Mode | Automatic, normal, single time |
Automatic Measurement | Peak, AVG Value, Max Value, Min Value, Frequency, Cycle |
When used as multimeter:
Item | Specification Parameters |
---|---|
DC Voltage | Automatic range, test range: ±600V |
AC Voltage | Automatic range, test range: ±600V |
DC Current | Automatic range, test range: ±10A |
(external sensors are required for large
range currents)
AC Current| Automatic range, test range: ±10A. Average value measurement
(external sensors are required for large range currents)
Resistor| Automatic range, test range: 0Ω~6MΩ
Diode| 0~2.0V
On-off Detection| Sound when it is lower than 50Ω
Oscilloscope Operation
3.1 Preparation before measurement
3.1.1 Start device and APP
- Long press the Power button on the oscillograph multimeter to turn on the device.
- Tap Oscilloscope in the main interface of “Toolbox” function of the detection tool (such as iSmartEV P01) to start the App.
No.| Description|
Operation Prompt
---|---|---
1| Menu
Include the following options:
Measure: provide 6 parameter measurement items.
Save: Set the save format and save path of channel waveform.
Show: Set the waveform display style.
User Settings: Provide functions such as data clearing, oscilloscope setting
and automatic calibration.
About: Display the specific information of the program.| Click once to expand
the submenu. Click again to retract the submenu.
2| Car Test
It provides various vehicle related test content (such as circuit, sensor,
actuator, commnication test, combined test) and corresponding test connection
methods.| Click once to expand the submenu. Click again to retract the
submenu.
3| Trigger
Used to set trigger channel and trigger type.| Click once to expand the
submenu to set channels and conditions. Click again to retract the submenu.
4| Horizontal Trigger Position Mark| Press and hold and drag left and right
to adjust the horizontal trigger position.
5| Save
It can quickly save the measurement waveform of the currently opened channel.|
To change the save path and file type, tap Menu -> Save to set.
6| Horizontal Setting Control the horizontal time base.| Click once to expand
the horizontal time base option and select the appropriate time base value.
7| Single Trigger Capture a trigger, complete the acquisition, and then stop.|
8| Auto|
| Click to enable the automatic range function. When the automatic range
function is enabled, the oscilloscope will automatically set various
parameters, including vertical scale, horizontal time base and trigger level.
When the signal is connected, these parameters will change automatically, and
there is no need to operate again after the signal changes. The oscilloscope
will automatically recognize and make corresponding changes.|
9| Wait/Run/Stop
Wait: All pre-triggered data has been obtained, and the oscilloscope is ready
to receive the trigger.
Run: Indicates that the oscilloscope is running.
Stop: Stop collecting data.|
10| Cursor Settings
Click to turn on/off the horizontal measurement cursor switch. When it is
turned on, two reference lines named Y1 & Y2 will appear in the waveform
display area of the screen.
Click to turn on/off the vertical measurement cursor switch. When it is
turned on, two reference lines named X1 & x2 will appear in the waveform
display area of the screen.| Click once to enable the cursor measurement
function. Click again to disable the function.
11| Connection Status Button| Click to search and connect devices, and
“Connected” will be displayed after successful connection.
12| Channel 1 Setup Panel
Control the amplitude of the displayed signal. You can set the inversion,
coupling mode and probe attenuation coefficient.| When the channel is enabled,
click once to disable the channel and hide the channel setting menu.
Click it again to enable the channel and expand the channel setting menu.
13| Channel 2 Setup Panel
Control the amplitude of the displayed signal. You can set the inversion,
coupling mode and probe attenuation coefficient.|
14| REF (Reference) Channel Setting Set the reference channel.| In the channel
setting panel area, press and slide the screen up to call up the REF reference
channel button, and click this button to call up the reference channel setting
menu.
15| Edge Trigger Level Identification| Press and hold the icon to drag up and
down to set the trigger level.
16| Channel 2 Voltage Scale| Click+/- to adjust the interval value of channel
2 voltage scale.
17| Channel selection button Click to select the target channel.| Click once
to call up the channel (only the opened channels are displayed) selection pop-
up window. Click again to close the window.
18| Fine-tuning button| When the horizontal cursor is turned on, the fine-
tuning buttons are displayed as and . If the vertical cursor is turned on,
the fine-tuning buttons are displayed as and .
19| Horizontal Time Base|
20| Measured Value Display Area| It can be called up through Menu -> Measure.
21| Channel 2 Mark Indicate the reference point of the displayed waveform. If
there is no mark, the channel is disabled and will not be displayed.|
22| Channel 1 Mark Indicate the reference point of the displayed waveform. If
there is no mark, the channel is disabled and will not be displayed.|
23| REF(Reference) Channel Mark Indicate the reference point of the displayed
waveform. If there is no mark, the channel is disabled and will not be
displayed.|
24| Waveform Display Area|
25| Channel 1 Voltage Scale| Click+/- to adjust the interval value of channel
1 voltage scale.
3.1.2 Communication Setting
The main connection methods between the Oscillograph Multimeter and the
detection tool are Wi-Fi communication and USB wired communication.
Wi-Fi communication
Click “Connect” to search for and connect the oscilloscope device. After
successful connection, the detection device screen will show the connection
status and the Wireless indicator on the Oscillograph Multimeter will light up
in green.
USB communication
When connecting the oscilloscope to the detection equipment via USB cable, the
system will automatically switch to USB communication mode. At this time, the
Wireless indicator on the Oscillograph Multimeter will be off.
3.1.3 Automatic Calibration
The auto-calibration program optimizes the oscilloscope signal path with
maximum measurement accuracy. The user can run this program at any time, but
shall run it if the ambient temperature changes by 10°C or more. In order to
calibrate more accurately, the oscilloscope must be powered on and warmed up
for 20 minutes before auto-calibration. The calibration mainly includes the
calibration of the analog channel, the trigger voltage in the trigger circuit
and the
horizontal baseline shift nonlinearity.
Note: During automatic calibration, please ensure that no signal is input
to the input terminal of CH1/CH2, otherwise the instrument may be damaged.
Tap Menu - > User Settings -> Automatic calibration.
Click OK on the window below to start calibration, and the message
“Calibration…Please wait.” will appear on the screen. When the automatic
calibration is finished, the “Calibration Successful” pop-up box will appear
on the screen.
3.1.4 Connection
When testing sensor:
- Connect the BNC connector end of the oscilloscope test clip to channel CH1/CH2 (select the channel number and quantity of channels as needed), connect the black connector of the other end to the black pin or black alligator clip, and connect the red connector to the other color pin or red alligator clip.
- Connect the black pin or black alligator clip to the ground wire port of the vehicle sensor, and connect the other color pin or red alligator clip connected with the red connector to the signal terminal of the vehicle sensor.
3.2 How to operate
3.2.1 Select channel
The system channels are CH1 (channel 1), CH2 (channel 2) and REF (reference
channel), please select channels as follows:
A. Select channels with the channel button on the right side of the screen.
B. Click to select target channel. This method is only applicable to opened
channels. Note: Each channel and waveform is marked with a different color for
better comparison and distinction by users.
The oscilloscope can display multiple waveforms at the same time, but only one
waveform is allowed to be displayed on the top layer. The channel that is
displayed on the top layer is called the current channel, and it will be
marked with The channel without this mark is not the current channel.
3.2.2 Channel attributes and trigger setting
- Horizontal time base setting The horizontal time base setting allows you to set the horizontal axis unit scale time size (time base value). Click “6-horizontal setting” button to expand the time base options and select the appropriate time base value.If waveform capture has been stopped, the waveform can be horizontally enlarged or reduced by horizontal time base adjustment.
- Channel setting panel The channel setting panel can be used to adjust the vertical scale and make other settings for the channel. Each channel has a separate settings panel, and each channel can be set up individually.
Click the target channel to call up the channel setting panel.
Description of setting options:
Menu Option | Description/Settings |
---|---|
DC/AC Coupling Mode | Trigger coupling is used to define which part of the |
signal passes through the trigger circuit. Channel coupling includes DC
coupling and AC coupling.
DC: DC coupling. The DC component and AC component contained in the measured
signal can pass through, and can be used to view waveforms as low as 0Hz
without large DC offset.
AC: AC coupling. The DC signal of the measured signal is blocked and only the
AC component is allowed to pass through, which can be used to view the
waveform with large DC offset.
Inversion| After the inversion switch is turned on, the voltage value of the
displayed waveform is inverted. The inversion will affect the display of the
channel. When the basic trigger is used, the trigger
level needs to be adjusted to keep the waveform stable.
Probe Type| Select the attenuation coefficient of the probe. The attenuation
coefficient changes the vertical scale of the oscilloscope so that the
measurement result reflects the true voltage value at the probe.
Vertical Scale Valu| Click +/- to adjust the vertical scale value (voltage
value).
Trigger setting
The trigger determines when the oscilloscope starts to acquire data and
display waveforms. If the trigger setting is reasonable, it can convert
unstable display or white screen into a meaningful waveform. When the
oscilloscope starts to acquire the waveforms, it acquires enough data to draw
the waveform to the left of the trigger point. While waiting for the trigger
condition to occur, the oscilloscope continues to acquire data. After the
trigger is detected, the oscilloscope continues to acquire enough data to draw
the waveform to the right of the trigger point.
Trigger means: set certain trigger conditions according to requirements, and
when a certain waveform in the waveform stream meets this condition, the
oscilloscope captures the waveform and its adjacent parts in real time and
displays them on the screen. Click “3-Trigger” to access the following
interface:
This oscilloscope uses edge trigger, which is the most common and effective trigger method, and the majority of Apps use this trigger method to trigger the waveform. Edge trigger means that the trigger is identified by finding the specified edge (rising edge, falling edge) and voltage level on the waveform. When the voltage of the signal under test changes in the same direction as the setting and its value changes to the same as the trigger voltage, the oscilloscope is triggered and captures the waveform.
Menu Option | Description/Settings |
---|---|
Source | Select the channel source of the trigger signal. |
Trigger | Level: Set the amplitude level that the signal must cross during |
waveform acquisition.
Rise: Triggered at the rising edge.
Drop: Triggered at the dropping edge.
Close: Turn off the trigger mode.
In this trigger mode, the user can directly drag the edge trigger level icon
to set the trigger level.
3.2.3 Automatic Setting
The oscilloscope has automatic setting function, which can set the
oscilloscope to display waveforms in the best way automatically.
Click Auto, the system automatically adjusts the horizontal and vertical
calibration of the oscilloscope, the coupling, type and position of the
trigger, and other settings, so as to obtain a stable waveform display.
3.2.4 Menu Operation
- Measure
The oscilloscope provides 6 types of parameter automatic measurement functions.
Click to select measurement function. All selected measurement functions are displayed to the left of the Clear button. The corresponding values are displayed at the bottom of the screen.To remove the measurement function, click again. Menu Option| Description/Settings
---|---
Cycle| The time between the threshold intermediate values of two consecutive, homogeneous edges.
Frequency| The reciprocal of the period.
Peak| The voltage value from the peak to the lowest point of the waveform.
Max value| The voltage value from the highest point of the waveform to GND (ground).
Min value| The voltage value from the lowest point of the waveform to GND (ground).
AVG value| The arithmetic average over the entire waveform or selected area.
The following figure explains the meaning of some measurement items, for reference only.Click Clear to close all measurement items.
-
Save
The save option is used to save the waveform of the channel. Click Save and the screen will display as below:First select the measurement channel, then select the measurement type WAV or CSV, then modify the name and save, and finally select to save to R1/R2. The saved files can be called by REF (reference) channel for reference and playback. -
Show
The show option is used to set the brightness of the waveform, coordinate axis display intensity, etc. The coordinate types include Full, Grid, Cross-hair and Frame. -
User setting
The user setting options can set clear data, waveform display automatic calibration and oscilloscope parameter save and restore, etc. Click User Settings, the screen will display as follows:Option Description: Menu Option| Description/Settings
---|---
Clear Data| Clear the saved data and user settings.
Oscilloscope Settings| Users can use the “Save” function to save the system setting parameters. The “Restore” function allows users to call the previously saved system settings to avoid duplicate settings.
Automatic Calibration| Automatic calibration can optimize the oscilloscope signal path with maximum measurement accuracy. -
About
Information about display App and firmware version.
3.2.5 Car Test
There are buttons for various vehicle related test content (including
Circuit, Sensor, Actuator, Communication test and Combined test) in the “Car
test” option. After the user selects the test content as required, the
oscilloscope will automatically set the corresponding parameters to achieve
the purpose of rapid setting. After selecting the function, please perform the
wiring test according to the prompt in the small box on the right.
3.2.6 Cursor Measurement
The “Cursor” option can be used to assist with measurements. Turn on the
cursor and place the cursor on the measurement point to read out the waveform
measurement value. There are horizontal cursor and vertical cursor, horizontal
cursors display horizontal lines to measure vertical parameters and vertical
cursors display vertical lines to measure horizontal parameters. Click cursor
option / two horizontal Y1&Y2/ vertical cursor X1&X2 measurement lines will
appear in the interface, click on the relevant line and drag to move the line
position. Click the “Cursor” option again, the function will be closed and the
auxiliary lines will disappear.
Note:
△ Reading: Indicates the difference between two cursor positions.
Voltage reading after Y1, Y2: Indicates the position of the activated cursor
in the horizontal cursor relative to the current channel identification point.
Time reading after X1, X2: Indicates the position of the activated cursor in
the vertical cursor with respect to the trigger point. 1/△X: Frequency.
3.2.7 Quick save
The “Quick Save” option can quickly save the measurement waveform of the
currently opened channel. The oscilloscope can save the waveform of analog
channel or mathematical channel to the local, the file type can be WAV or CSV.
The oscilloscope provides two reference channels, which can be called to load
WAV type files to the reference channel and open the reference channel to
display the reference waveform. The relevant settings can be found in “Menu”.
3.2.8 REF (Reference) Waveform
The oscilloscope provides REF channel for displaying reference waveform. Users
can load the previously saved waveform file into the reference channel by
calling, and compare it with the actual waveform to find out the difference.
- If the previous waveform file is saved in R1, click the button under “R1 Reference Waveform” as shown in the figure below to call up the list of saved waveform (R2 reference waveform operation is the same as R1 reference waveform).
- Click the reference waveform to be viewed to display the waveform on the screen, and click the blank area of the screen to hide the reference waveform list.Click ON/OFF button to display/hide reference waveform.
Multimeter Operation
4.1 Preparation before measurement
4.1.1 Start device and APP
- Long press the Power button on the Oscillograph Multimeter to turn on the device.
- Tap Multimeter in the main interface of “Toolbox” function of the detection tool (such as iSmartEV P01) to start the App.
4.1.2 Communication Setting
The main connection methods between the Oscillograph Multimeter and the
detection tool are Wi-Fi communication and USB wired communication.
Wi-Fi communication
Click Not connected to search for and connect the multimeter device. After
successful connection, the detection device screen will show the connection
status and the Wireless indicator on the Multimeter will light up in green.
USB communication
When connecting the multimeter to the detection equipment via USB cable, the
system will automatically switch to USB communication mode. At this time, the
Wireless indicator on the Oscillograph Multimeter will be off.
4.2 How to operate
Prepare the required red and black multimeter test leads, and find the
multimeter measurement ports on the top of the tool.
The multimeter can measure voltage, current, resistor, diode and on-off.
Different measuring objects have different connection methods.
4.2.1 Voltage Measurement
The connection method for measuring DC voltage is the same as that for
measuring AC voltage.
- Select “DC Voltage” or “AC Voltage” and the corresponding range.
- Insert one end of the black multimeter test lead into the “COM” end and one end of the red multimeter test lead into the “V/Ω” end.
- Connect the black and red test leads to the power supply or load under test. Keep contact stable.
- Tap Start, the value will be displayed on the screen.
Warning: The head of the multimeter test lead is metal. During the measurement, do not touch it with hands, otherwise it will not only affect the measurement results, but also may cause electric shock.
Option Description:
Numerical waveform mode: Display the measurement results in the form of
numerical value and waveform.
Numerical mode: Display the measurement results in numerical mode.
Waveform mode : Display the measurement results in waveform mode.
: Open the saved waveform file.
: Save the measurement results of the current screen as a waveform file.
4.2.2 Current Measurement
The connection methods for measuring DC current and AC current are the same.
- Select “DC current” or “AC current” and the corresponding range.
- Insert one end of the black multimeter test lead into the “COM” end. If the current is greater than 400mA, insert one end of the red multimeter test lead into the “A” end. If the current is less than 400mA, insert one end of the red multimeter test lead into “mA μA” end.
- Connect the black and red test leads to the circuit under test. Keep contact stable.
- Tap Start, and the value will be displayed on the screen.
4.2.3 Resistance Measurement
- Select “Resistor”.
- Insert one end of the black multimeter test lead into the “COM” end and one end of the red multimeter test lead into the “V/Ω” end.
- Connect the black and red test leads to the metal parts at both ends of the resistance. Keep the contact between the test lead and the resistance stable.
- Tap Start, and the value will be displayed on the screen.
Note: During the measurement, you can touch the resistance by hand, but do not touch both ends of the resistance at the same time, which will affect the measurement accuracy.
4.2.4 Diode Measurement
The multimeter can also measure light emitting diodes and rectifying diodes.
The multimeter test lead position is the same as the voltage measurement.
- Select “Diode”.
- Insert one end of the black multimeter test lead into the “COM” end and one end of the red multimeter test lead into the “V/Ω” end.
- Connect the red test lead to the positive electrode of the diode and the black test lead to the negative electrode. Keep the contact between the test lead and the diode stable.
- Tap Start, and the forward conduction voltage reading of the diode will be displayed on the screen.
4.2.5 On-off Measurement
- Select “ON/OFF”.
- Insert one end of the black multimeter test lead into the “COM” end and one end of the red multimeter test lead into the “V/Ω” end.
- Connect the red and black test leads to the circuit under test.
- Tap Start, the measurement results will be displayed on the screen. If the resistance of the circuit under test is ≤50Ω, the buzzer will sound; If the resistance of the circuit under test is ≥610Ω, 0.L will be displayed on the screen.
4.3 Detection Examples
Detection of knock sensor
(1) Detection of knock sensor resistance Turn the ignition switch to the “OFF”
position, disconnect the lead connector of the knock sensor, and detect the
resistance between the knock sensor connecting terminal and the housing via
resistance measurement, which should be ∞ (non-conductive). If it is 0Ω
(conductive), the knock sensor must be replaced. For magnetostrictive knock
sensor, the resistance measurement can also be used to detect the coil
resistance. The resistance value shall meet the specified value (Refer to the
maintenance manual of the corresponding model for specific data). Otherwise,
the knock sensor must be replaced. (2) Inspection of knock sensor output
signal Unplug the connecting plug of the knock sensor and check the voltage
between the knock sensor connecting terminal and the grounding with the “AC
voltage” measuring gear when the engine is idling. There should be pulse
voltage output.
If not, the knock sensor must be replaced.
Detection of cooling water temperature sensor (1) Resistance detection of
cooling water temperature sensor On-vehicle inspection: Turn the ignition
switch to OFF position, remove the cooling water temperature sensor wire
connector, and test the resistance value between the two terminals of the
sensor via resistance measurement. The resistance value is inversely
proportional to the temperature (negative temperature coefficient), and shall
be less than 1KΩ when the engine is hot. Single piece inspection: Unplug the
cooling water temperature sensor wire connector, and then remove the sensor
from the engine. Place the sensor in the water in the beaker, heat the water
in the beaker, and measure the
resistance value between the two terminals of the water temperature sensor
under different water temperature conditions via resistance measurement.
Compare the measured value with the standard value. If it does not meet the
standard, the water temperature sensor should be replaced. (2) Output signal
voltage detection of cooling water temperature sensor Install the cooling
water temperature sensor and plug the wire connector of the sensor. When the
ignition switch is turned to the ON position, test the sensor output voltage
signal from the two terminals of the water temperature sensor wire connector.
The measured voltage value shall change inversely with the cooling water
temperature. When the cooling water temperature sensor harness is disconnected
and the ignition switch is turned on, the voltage should be about 5V.
4.4 Precautions
- The head of the multimeter test lead is metal. Do not touch it with hands during measurement, otherwise it will not only affect the measurement results, but also cause electric shock.
- Before the measurement, calibrate the measuring range and the jack inserted by the test lead, and then carry out the measurement after there is no error.
- If the measured value cannot be estimated before measurement, the highest range shall be used for measurement first, and then the appropriate range shall be selected according to the measurement results.
- It is strictly prohibited to switch the range when measuring high voltage or large current to prevent arcing and burning the switch contacts. To shift gears, the metal contacts must be disconnected first.
- It is strictly prohibited to measure the resistance when the circuit under test is live to avoid damaging the instrument.
- When measuring DC power, select appropriate gear. For different components, the current is different. You can refer to the marked parameters of components to switch gears. During measurement, it is connected to the circuit in series, and then measured one by one. The voltage of the branch can be disconnected first. In particular, it is forbidden to connect the multimeter in parallel in the circuit, which will not only damage the multimeter but also cause casualties.
Maintenance
Note: To avoid damage to the oscilloscope or probe, do not expose it to
mist, liquids or solvents.
Cleaning
Check the Oscillograph Multimeter and probe frequently in accordance with the
requirements of operating conditions, clean the external surfaces of the
instrument as follows.
- Use a lint-free cloth to clean the outside of the Oscillograph Multimeter and probe from floating dust.
- Use a soft cloth moistened with water to clean the oscilloscope.
Note: To avoid damaging the surface of the Oscillograph Multimeter or probe, do not use any corrosive reagents or chemical cleaning reagents.
FCC Warning
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
Warranty
This WARRANTY applies only to customers and dealers who have purchased Smart
Safe products through normal procedures.
Within one year from the date of delivery, Smart Safe Company shall guarantee
the defects of its electronic products caused by materials or processes.
Damage of the equipment or components caused by abuse, unauthorized
modification, use for purposes other than the design of the product, or
failure to operate in the way specified in the instruction shall not be
covered by this warranty.
Disclaimer
The warranty mentioned above may supersede any other warranty.
Order notification
The replaceable parts and optional parts can be ordered directly from the
suppliers authorized by Smart Safe. Please specify when ordering:
- Quantity ordered
- Part number
- Part name
Customer Service Center
If the equipment needs to be repaired, please send the equipment to Smart
Safe, together with the purchase invoice and problem description. If the
equipment is within the scope of the warranty, Smart Safe offer free
maintenance; If the equipment is outside the scope of the warranty, Smart Safe
will charge for maintenance and return freight.
Address of SmartSafe Company:
3310, Building 11, Tian ‘an Yungu Industrial Park, Bantian Street, Longgang
District, Shenzhen, Guangdong, China. Postcode: 518110
Statement: The Company reserves the right to change the product design
and specifications without prior notice. The appearance and color of the
object may be different from that shown in the instruction manual. The object
shall prevail. We have tried our best to make all the descriptions in the book
accurate, but there are still some inaccuracies. If you have any doubt, please
contact the distributor or after-sales service center. The company will not
assume any consequences caused by misunderstanding.