MINOSTON MP21ZD Z-Wave Plug Dimmer Smart Plugs User Manual

June 17, 2024
Minoston

MINOSTON MP21ZD Z-Wave Plug Dimmer Smart Plugs

MINOSTON-MP21ZD-Z-Wave-Plug-Dimmer-Smart-Plugs-product

Product Information

Specifications :

  • Input: 125VAC 60Hz
  • Frequency: 908.42 MHz
  • Loading: 200W Incandescent, 100W Dimmable CFL/LED
  • Indoor use in a dry location
  • LED indicator
  • Blue: Light status indicator
  • Blue: ADD / Inclusion
  • Purple: Remove / Exclusion
  • Red: Network Failure
  • Program button
  • Press 1x: Manually
  • Press 3x: Z-Wave Network configuration
  • Reset: Press the button twice quickly then hold a 3rd press for 10 seconds

Features:

  1. Z-Wave on/off + dimmer control.
  2. Grounded 3-wire power connection for safety.
  3. Remember and restore the on/off status after power failure.
  4. Built-in Z-Wave Plus signal repeater to extend network range.
  5. S2 security and 800 Z-Wave chip for reliable wireless communication.
  6. Work with all certificated Z-Wave controllers.
  7. Support Long Range.

Brightness Level Setting:

Minimum Brightness Level Setting (Refer to Parameter 11):

  1. Press the button 5 times quickly, the LED indicator flashes slowly to enter the setting Min brightness mode.
  2. The lamp will adjust to the minimum brightness automatically.
  3. Hold the button to adjust the brightness of the bulb and select the appropriate brightness to set the minimum brightness.
  4. Press the button 5 times quickly to confirm the setting (the minimum brightness setting is completed). The LED indicator will flash 3 times.

Maximum Brightness Level Setting (Refer to Parameter 12):

Please contact us for instructions on how to set the maximum brightness level.

Z-Wave Interoperability:

Adding Device to Z-Wave Network for QR Code:
Scan the provided QR code for SmartStart inclusion. Note: FULL DSK can be found on the packaging box. Do not remove or damage them.

Z-Wave Network Configuration:

  1. Follow the instructions for your Z-Wave-certified controller to add a device to the Z-Wave network.
  2. Once the controller is ready to add your device, press the Manual/Program button on the smart plug 3 times quickly.

Z-Wave Long Range:

To remove the device, follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. Once the controller is ready to remove your device, press the Manual/Program button on the smart plug 3 times quickly. The green light will be on for 2 seconds when the removal is successful.

To Return the Device to Factory Defaults:

  • Manual: Press the button twice quickly then hold a 3rd press for 10 seconds.
  • Host reset: Remove it from the hub, and the device will be restored to factory default.

Association Group:

(LED flashes twice when the configuration parameter changes.) Support 2 groups, each group can support up to 5 devices.

  • Group 1: Lifeline
  • Group 2: Left outlet sends a basic set

SmartThings Usage Exceptions:

If the SmartThings replacement service results in abnormal use of the product, please install a new driver (edge driver) according to the following solutions:

  1. Scan the provided QR code to open the SmartThings Edge Driver subscription channel of the product.
  2. Log in to the SmartThings account after opening the SmartThings Edge Driver subscription channel.
  3. Select the SmartThings Hub you are using, and click Enroll.
  4. After Enroll is completed, click Available Drivers.
  5. After entering the Available Drivers page, select Z-Wave Switch to Install. Note: Please scan the QR code provided to view the guide video.

FAQ:

  • Q: What is the input voltage and frequency?
    A: The input voltage is 125VAC and the frequency is 60Hz.

  • Q: What is the maximum loading capacity for different types of bulbs?
    A: The maximum loading capacity is 200W for Incandescent bulbs and 100W for Dimmable CFL/LED bulbs.

  • Q: Does it support Z-Wave Plus?
    A: Yes, it has a built-in Z-Wave Plus signal repeater for extended network range.

  • Q: Can I use it with any Z-Wave controller?
    A: Yes, it works with all certificated Z-Wave controllers.

If you have any further questions or need assistance, please contact us at [email protected] or visit our website www.minoston.com.

LED indicator

  • Blue: Light status indicator
  • Blue: ADD / Inclusion
  • Purple: Remove / Exclusion
  • Red: Network Failure

Program button

  • Press 1x: Manually
  • Press 3x: Z-Wave Network configuration
  • Reset: Press the button twice quickly then hold a 3rd press for 10 seconds

Features

  1. Z-Wave on/off + dimmer control.
  2. Grounded 3-wire power connection for safety.
  3. Remember and restore the on/off status after power failure.
  4. Built-in Z-Wave Plus signal repeater to extend network range
  5. S2 security and 800 Z-Wave chip for reliable wireless communication.
  6. Work with all certificated Z-Wave controllers.7. Support Long Range.

Min Brightness Level Setting( Refer to Parameter 11)

  1. Press the button 5 times quickly, the LED indicator flashes slowly to enter the setting “Min brightness” mode. The lamp will adjust to the minimum brightness automatically.
  2. Hold the button to adjust the brightness of the bulb, and select the appropriate brightness to set the minimum brightness.
  3. Press the button 5 times quickly to confirm it (the minimum brightness setting is completed). The LED indicator will flash 3 times.

Max brightness Level Setting( Refer to Parameter 12)

  1. Press the button 10 times quickly, the LED indicator flashes slowly to enter the setting”Max brightness” mode. The lamp will adjust to the maximum brightness automatically.
  2. Hold the button to adjust the brightness of the bulb, and select the appropriate brightness to set the maximum brightness.
  3. Press the button 10 times quickly to confirm it (the max brightness setting is completed). The LED indicator will flash 3 times.
    Remark : If the setting is not confirmed at Step 3, the setting mode will be exited after 10S.

Please contact us if you have any questions:

www.minoston.com
[email protected]

Z-WAVE INTEROPERABILITY

This product can be included and operated in any Z-Wave network with other Z -Wave-certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the “Device Reset Locally” function.

Adding Device to Z-Wave Network for QR Code

MINOSTON-MP21ZD-Z-Wave-Plug-Dimmer-Smart-Plugs-fig-
\(2\)

Z-Wave Network Configuration

Adding Device to Z-Wave Network

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave
  2. Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly.

Z-Wave Long Range
Note: MP21ZD supports Z-Wave Long Range
The device is compatible with smartstart.SmartStart-enabled products can be added to a Z-Wave network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No furthe action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.
Note: Z-Wave Long Range device can only support be included via SmartStart. Extract the DSK from the end device and paste it into the DSK Value in the PC Controller, and make sure the Long Range’ option is ticked.
To Remove the Device
1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
2. Once the controller is ready to remove your device, press the manual/program button on the smart plug 3 times quickly.
The green light is on for 2s when the removal is successful.
To Return the Device to Factory Defaults
Manual: press the button twice quickly then hold a 3rd press for 10 seconds.
Host reset: Remove it from the hub, and the device will be restored to factory default.

Association Group

(LED flashes twice when the configuration parameter changes.)

  • Support 2 groups, each group max support 5 devices
  • Group 1 lifeline
  • Group 2 Left outlet send basic set.

Regarding SmartThings Usage Exceptions:
If the SmartThings replacement service results in abnormal use of the product, please install a new driver(edge driver) according to the following solutions .MINOSTON-MP21ZD-Z-Wave-Plug-Dimmer-Smart-Plugs-fig-
\(3\)

  1. Scan the above QR code(left)to open the SmartThings Edge Driver subscription channel of the product.
  2. Log in to the SmartThings account after opening the SmartThings Edge Driver subscription channel.
  3. Select the SmartThings Hub you are using, and click “Enroll”.
  4. After “Enroll” is completed, click “Available Drivers”.
  5. After entering the “Available Drivers” page, select “Z-Wave Switch” to “Install”. Note: Please scan the QR code on the right to view the guide video.

Parameter Settings

LED Indicator
This parameter can allow you to choose the LED indicator to be on when the plug(light) is on/off, or LED indicator remains on/off all times. (LED flashes 3 times when the configuration parameter changes.) — Parameter =2, size =1byte, Default =0

  • Value=0 (default) LED is On when the switch (light) is Off.
  • Value=1 — LED is On when the switch (light) is On.
  • Value=2 — LED is always Off.
  • Value=3 — LED is always On.

Auto Turn-Off Timer
This parameter can access you to set a timer to make the switch turn off automatically after the switch turns on.The number entered as a value corresponds to several minutes. Operation: Set up on the hub. (LED flashes 3 times when the configuration parameter changes.) — Parameter =4, Size=4, Value: 0-65535(minutes); Value=0(default) disable

Auto Turn-On Timer
This parameter can allow you to set a timer to make the switch turn on automatically after the switch is turned on.The number entered as a value corresponds to several minutes. Operation: Set up on the hub. (LED flashes 3 times when the configuration parameter changes.) — Parameter =6, Size=4, Value: 0-65535(minutes); Value=0(default) disables turn on the outlet

Night Light Set

This parameter can allow you to set a specific brightness for the light when you want to make it as a night light.
(LED flashes 3 times when the configuration parameter changes.)
— Parameter =7, Size=1, Default = 2
Value=1 — 10% brightness
Value=2 — 20% brightness
/
Value=10 — 100% brightness

Restores State After Power Failure

This parameter can allow you to set the switch to be on/off after power failure. Operation: quickly press 8 times to change this parameter.
(LED flashes 3 times when the configuration parameter changes.)
Parameter=8, Size=1, Value=2(default)
Value=0 — The switch is off regardless of the state before power failure.
Value=1 — The switch is on regardless of the state before power failure.
Value=2(default) memory state before power failure
This switch will be state return prior to the power failure after power is restored.

Dimmer Speed (On/Off Control)

This parameter can access you to set the time from maximum brightness to minimum brightness or minimum brightness to maximum brightness
(Only when turn ON/ OFF the light ) Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=9, Size=1, Default = 2
Value=0 —instant on/off
Value-1— from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2—from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
/
Value-10— from 0x63 to 0x00 or from 0x00 to 0x63 need 10s

Dimmer Speed (Dimmer Control)

This parameter can access you to set the time from maximum brightness to minimum brightness or minimum brightness to maximum brightness.
(Only when hold it to change the brightness or control from HUB).
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=10, Size=1, Default=4
Value=1—from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value-2—from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
/
Value=10—from 0x63 to 0x00 or from 0x00 to 0x63 need 10s

Multilevel Minimum Value Can Be Set

Operation: quickly press 5 times to change this parameter. (LED flashes 3 times when the configuration parameter changed.) —Parameter=11, Size=1, Default = 10
Value=0 — disable
Value=1
/
Value=99

Multilevel Maximum Value Can Be Set

Operation: quickly press 10 times to change this parameter. (LED flashes 3 times when the configuration parameter changed.) —Parameter=12, Size=1, Default =99
Value=0 — disable
Value=1
/
Value=99

FCC / IC

This device complies with part 15 of the FCC and Industry Canada license- exempt RSS standard(s). Operation is subjected to the following two conditions: (1) This device may not cause harmful interference, (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE : The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Important note : To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.

CAUTION – PLEASE READ!
This device is intended for installation by the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada If you are unsure or uncomfortable about performing this installation consult a qualified electrician.

WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING-TYPE POWER OUTLET. IF THE PLUG DOES NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.

CONTROLLING APPLIANCES:
CAUTION : TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT

  • DO NOT EXCEED RATINGS
  • DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)

MEDICAL EQUIPMENT
Please DO NOT use this switch to control Medical or Life Support equipment. Z-Wave devices should never be used to control the On / Off status of Medical and / or Life Support equipment.

CONTROLLING APPLIANCES
Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. The reason is that the appliance you want to control may be in a separate room and if unintentional behavior occurs (such as adevice turning on or off – either intentionally via schedules or unintentionally via network error) this event may lead to a hazardous condition. For these reasons, please note the following suggestions:

  1. Do not include Z-Wave devices in Groups or Scenes if they control appliances.
  2. Do not use Z-Wave devices to control electric heaters or any other appliances that may present a hazardous condition due to unattended, unintentional, or automatic power control.

Generic Device Class:
0x11-GENERIC_TYPE_SWITCH_MULTILEVEL

Specific Device Class:
0x00-SPECIFIC_TYPE_NOT_USED

Command Classes:

  • 0x5E-COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
  • 0x26-COMMAND_CLASS_SWITCH_MULTILEVEL_V4,
  • 0x70-COMMAND_CLASS_CONFIGURATION_V4,
  • 0x85-COMMAND_CLASS_ASSOCIATION_V2,
  • 0x8E-COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3, 0x59-COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3, 0x55-COMMAND_CLASS_TRANSPORT_SERVICE_V2,
  • 0x87-COMMAND_CLASS_INDICATOR
  • 0x86-COMMAND_CLASS_VERSION_V3,
  • 0x72-COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, 0x5A-COMMAND_CLASS_DEVICE_RESET_LOCALLY, 0x73-COMMAND_CLASS_POWERLEVEL,
  • 0x9F-COMMAND_CLASS_SECURITY_2,
  • 0x6C-COMMAND_CLASS_SUPERVISION,
  • 0x7A-COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Minoston User Manuals

Related Manuals