AIR 12V Battery Charger Booster
User Manual
SAFETY INSTRUCTIONS
This manual includes guidelines on the operation of your device and the
precautions to follow for your own safety. Ensure it is read carefully before
first use and keep it handy for future reference. These instructions should be
read and understood before anyone operates the product.
Any modifications or maintenance that are not specified in the manual should
not be undertaken. The manufacturer is not liable for any injury or damage due
to non-compliance with the instruction manual.
In case of problems or uncertainties, please consult a qualified person that
is able to handle the device correctly. This device should only be used for
charging and/or start-up and/or power supply within the limits indicated on
the device and in the manual.
The safety instructions must be followed. In case of improper or unsafe use,
the manufacturer cannot be held responsible.
The device is suitable for indoor use only. Do not expose to rain or excessive
moisture (charger).
This device may be used by children from age 8 and by persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge,
provided that they are under supervision or have been told how to use the
device safely and are aware of the potential risks. Children must not use the
device as a plaything. Cleaning and servicing tasks may not be carried out by
children unless they are supervised.
Do not use it for charging non-rechargeable batteries.
Do not use any charger other than the one supplied with the machine to charge
the batteries.
Do not operate the device with a damaged power supply cord or a damaged mains
plug.
Never charge a frozen or damaged battery.
Do not cover the device.
Do not place the device near a fire or subject it to heat or to long-term
temperatures exceeding 50°C.
Do not obstruct the cooling vents. Refer to the installation section before
operating the machine.
The automatic mode of operation and usage restrictions are explained below in
these operating instructions.
Risk of explosion or acid projection in case of short-circuiting of the clamps
or if the 12V booster is connected to a 24V vehicle or vice versa.
Risk of explosion and fire!
A battery being charged can emit explosive gas.
- During the charge, the battery must be placed in a well-ventilated area.
- Avoid flames and sparks. Do not smoke.
- Protect the electrical contacts of the battery against short-circuiting.
Connection/disconnection:
-
Disconnect the power supply before connecting/disconnecting the device to/from the battery.
-
The terminal of the battery that is not connected to the car frame must be connected first.
The other connection must be made on the car frame, far from the battery and the fuel line. The battery charger must be connected to the power supply network. -
After the charging process, disconnect the battery charger from the power supply network and remove the connector from the car frame and then the connector from the battery, in this order.
Acid projection hazard!
- Wear safety goggles and protective gloves
- If your eyes or skin come into contact with battery acid, rinse the affected part of the body with plenty of water and seek immediate medical assistance.
Connection:
- Class II device (charger booster)
- Class III device (booster)
- Connection to the mains must be made according to the national installation regulations.
Maintenance:
- If the charging/power supply cable is damaged, the product must be disposed of.
- Service should be performed by a qualified person
- Warning! Always disconnect from the mains before performing maintenance on the device (charger & booster).
- If the internal fuse is blown, it must be replaced by the manufacturer, its after-sales service or an equally qualified person.
- Under no circumstances should solvents or other aggressive cleaning agents be used.
- Clean the device’s surfaces with a soft, dry cloth.
Regulations:
- The device complies with European Directive.
- The certificate of compliance is available on our website.
- EAC conformity mark (Eurasian Economic Commission)
- Equipment in compliance with British requirements. The British Declaration of Conformity is available on our website (see home page).
- Equipment in conformity with Moroccan standards. The declaration C م (CMIM) of conformity is available on our website (see cover page).
Disposal:
- This product should be disposed of at an appropriate recycling facility. Do not dispose of domestic waste.
- The battery fitted in this device is recyclable. Please proceed according to the applicable recycling regulations.
- The battery must be removed from the device before the latter is discarded.
- The device must absolutely be disconnected from the power supply network before removing the battery.
Disposal:
- This product should be disposed of at an appropriate recycling facility. Do not dispose of in the domestic waste.
- The battery fitted in this device is recyclable. Please proceed according to the applicable recycling regulations.
- The battery must be removed from the device before the latter is discarded.
- The device must absolutely be disconnected from the power supply network before removing the battery.
GENERAL DESCRIPTION
The high-performance internal battery allows the GYSPACK AIR to serve 5 functions:
- Test battery
- Instant Start (1250 A peak /480 A) from a vehicle equipped with a 12V Lead battery (Gel or Liquid electrolyte).
- 4 Bars Compressor (13 L/min) for inflating wheels, balloons …
- 12 V DC power supply, to supply light Spot, TV, tools, etc…
- Light
To ensure good working conditions and optimize the durability of its internal battery, it is important to recharge it after each use and leave it plugged in until the next usage.
BATTERY TEST FEATURE
Test of internal battery before the start
In order to test the internal battery, press and the result will be displayed:
Greenlight: Internal battery is charged. Starting is possible
Orange light :
Red light:
Attention !!! Please do not use the machine when the orange or red light
is lit! You need to recharge it first.
STARTING A VEHICLE
Do not disconnect the battery from the vehicle. Disconnecting the battery may
result in a loss of information and a possible inability to restart.
The booster must be stored in a vertical position. Any other storage position
should only be temporary.
In order to use the GYSPACK AIR as a starter, follow these steps:
• Disconnect the GYSPACK AIR from the mains. Turn the vehicle ignition key to
OFF.
• Position the switch «OFF».
• Connect the red clamp to the + terminal of the battery, and the black one to
the – terminal. A
buzzer will indicate any polarity inversion.
The cables must not be pinched or in contact with hot or sharp surfaces.
-
Switch the commutator on ON (« Turn on the GYSPACK AIR»)
-
Go to the driver’s seat and turn the ignition key (6-sec max). If your engine does not start, wait 3 minutes until the next attempt.
-
If the cooling period between each attempt (3 minutes) is not observed or if the duration of the attempt is too long (> 6 seconds), the chances of a successful jumpstart are significantly reduced (risk of power loss).
-
Risk of battery acid leaks or damage if the recommended periods are not observed.
-
If the vehicle does not start, it may be a problem other than a faulty battery: alternator, glowplug…
Risk of explosion or acid splashes when connecting a 12 V booster to a 24 V vehicle. Beware of possible short-circuit of the clamps. -
Position the switch «OFF».
-
Unplug the black clamp, then the red one from the vehicle.
-
Recharge your GYSPACK AIR after use. (see ‘Charging internal battery)
CHARGING INTERNAL BATTERY USING INTEGRATED CHARGER
The GYSPACK AIR is fitted with an automatic charger that maintains the
internal battery fully charged without the need for monitoring. When the
battery is fully charged, the charger will automatically go into floating
mode and stop the charge. It will automatically restart when needed.
To recharge the GYSPACK AIR :
- Place the GYSPACK AIR in a vertical position during the charge.
- Plug in the power supply to an outlet 230 V and the other end on the front of GYSPACK AIR (n°2 fig p. 41).
- The green indicator indicates the charge that the GYSPACK AIR is over.
Nb: If the device stays more than 24 hours in charging mode (red LED, orange indicator on), then manually stop the
charge. The internal battery of your GYSPACK AIR is damaged.
USING THE GUYS PACK AIR AS A 12V DC POWER SUPPLY
The cigarette lighter plug is protected by an integrated 20 A circuit breaker.
In the event of an overheating due to an overcharge, the circuit breaker will
stop the power supply.
OFF Position the switch «OFF».
Open the lead of the cigarette lighter plug Remove the cigarette lighter and
plug the lead into the hole (n°1 fig p. 65).
Plug your electrical device into the plug of GYSPACK AIR, using the proper
cable (not included).
Estimated autonomy of GYSPACK AIR as a 12 V DC power supply
Device| Estimated consumption (in watts)| Estimated autonomy (in hours)
Fluorescent cellular light| 4| 50
Radio, Fan, Echoprobe| 9| 22
Videocamera, light spot| 15| 13
Power tool, drying pump| 24| 8
Air Compressor, Car vacuum cleaner| 80| 2
SPOT-LIGHT
The GYSPACK AIR has an in-built spotlight comprised of 7 high-intensity LEDs
controlled by the «light» button (n°11 fig p. 65).
Repair should always be carried out by qualified personnel.
AIR COMPRESSOR
GYSPACK AIR integrates a 4 bars compressor, allowing to inflate :
- Tires with their original valve. (press the lever to lock the hose on the valve).
- Balloons with thin ends (included).
- Any other plastic objects (beach balloons, toys, air beds, etc.) with 2 special ends “connectors”
Usage
-
Turn the GYSPACK AIR main switch to « off »
-
Press the “ON” button to start the compressor.
Nb: the compressor can work for 10mn maximum. Please wait for 10mn between the next use. -
Flowmeter indicates the current air pressure
-
Stop the compressor when the required pressure is reached
USE OF CIGARETTE LIGHTER PLUGS
This type of cigarette lighter connection lead is limited to 10A. Supplied
with some of our GYSPACK, they are SOLELY designed for memory backup. Any
other use can be dangerous.
Risk of fire! We strongly advise against using the cigarette lighter lead to
jump-start or power a 12V appliance for instance.
TROUBLESHOOTING
Troubleshooting | Causes | Solutions |
---|---|---|
The device beeps. | The device detects a polarity reversal. | Check the battery |
polarity.
Sparks appear when the clamps make contact with the battery terminals.| The
switch is on position «ON».| Switch the machine off before connecting the
clamps to the battery.
The position of the negative and positive clamps on the battery terminals is
incorrect (polarity reversal).| Check the battery polarity.
The unit can not start the vehicle.| The switch is in the OFF position.| Set
the switch to the ON position.
The unit can not start the vehicle. One of the red or orange LED on the unit
switches on in “test” mode.| The internal battery is discharged.| Charge the
unit, and try again after
the charge is complete.
Several jump-start attempts without pause between each.| Wait 3 minutes
between 2 starts. A start must not last more than 6 seconds.
The battery voltage is incorrect..| Check that the battery voltage of the
vehicle is 12V.
The device can not start the vehicle anymore and no one LED of the device
switches on in ‘Test” mode.| The voltage of the internal batteries is very
low. It may be that the internal batteries are damaged.| Put the device on
charge in order to attempt to recover the battery.
The internal battery is damaged and it cannot be recharged.| Contact the GYS
after-sale service to replace the battery.
The charge of the internal battery does not start (none of the charging LEDs
activate).| The external charger plug is not
connected correctly to the socket of the machine.| Check that the plug is
connected correctly to the machine.
After a day of charge, the end of charge indicator does not activate.| The
internal batteries are damaged and cannot be recharged.| Contact the GYS
after-sale service to organize a replacement of the batteries.
In external 12V power source mode, the booster no longer delivers power.| The
internal thermal protection cir-
cuit-breaker has cut the circuit.| Disconnect the external device connected to
the machine and wait for the circuit breaker to reset itself automatically.
The lamp does not switch on.| The internal battery is discharged.| Charge the
unit, and try again after
the charge is complete.
The air compressor does not start.
BATTERY NOT COVERED BY WARRANTY
Batteries are live parts, their life depends on maintenance. After each use of
this starter, it is essential to recharge the internal batteries. Storage in
places with high temperatures greatly reduces the battery charge. In the case
of prolonged non-use, it is strongly recommended to recharge the batteries
before use. In general, we recommend leaving the product plugged in
continuously to maintain the batteries at their best performance.
This product is equipped with 2 high-performance batteries if the maintenance
instructions are not followed the batteries can deteriorate irreversibly over
time.
For this reason, the GYSPACK batteries are excluded from the warranty.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase
(parts and labour).
The warranty does not cover:
- Transit damage.
- Normal wear of parts (eg. : cables, clamps, etc..).
- Damages due to misuse (power supply error, dropping of equipment, disassembling).
- Environment-related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
– The proof of purchase (receipt etc …)
– A description of the fault reported
BATTERY REPLACEMENT:
To replace the battery :
- The booster must be disconnected from the power supply.
- First, the back panel must be unscrewed (15 screws) and removed.
- Once the back panel is removed, the battery front appears (cf illustration). The battery is connected to the GYSPACK
AIR at two points: at the – terminal (illustration 1 ) and at the + terminal (illustration 2 ). To remove the battery, remove the 2 screws that enable the connection between the battery and the GYSPACK AIR at the terminals + and -.
When putting in a new battery, make sure to observe the polarities of both the battery and the GYSPACK AIR. Terminal – on the left, terminal + on the right (cf illustration). Put the 2 screws and washers back, and tighten the nuts (recommended torque wrench 4 N.m).
- Place the booster’s back panel screws back on.
PRODUCT INTERFACE
SPECIFICATION
Interne Batterie | 12V/18Ah |
---|---|
Voltage input | 100V-240V 50/60Hz |
Charger’s maximum nominal power | 16 W |
Charging voltage | 16 V |
Charging current | 500 mA |
Nominal charging capacity | 22 Ah |
Charging curve | WU |
Storing temperature | -18 °C / +45 °C |
Protection rating | IP20 |
Machine weight (including all cables) | 10 Kg |
Dimensions (L x l x H) | 33 cm x 17 cm x 37 cm |
CIRCUIT DIAGRAM
GUYS SAS
1, rue de la Croix des Landes
CS 54159
53941 SAINT-BERTHEVIN Cedex
FRANCE