MIDMARK 622 Barrier Free Examination Table User Guide

May 15, 2024
Midmark

MIDMARK-LOGO

MIDMARK 622 Barrier Free Examination Table

Barrier-FreeTM Examination Table
Specifications

  • Model Numbers: 622, 623
  • Weight: 181 kg (400 lbs)
  • Duty Cycle: 30 seconds ON, 5 minutes OFF
  • ETL Classification: 42185
  • Regulatory Compliance: UL STD 60601-1, CAN/CSA STD C22.2 NO 601.1

Important Information
Safety Symbols:

  • Caution: Indicates a potentially hazardous situation which could result in injury if not avoided.
  • Equipment Alert: Indicates a potentially hazardous situation which could result in equipment damage if not avoided.
  • Note: Amplifies a procedure, practice, or condition. Consult User Guide for important information.

Proper shipping orientation

  • Keep dry
  • Maximum stacking height (palleted units)
  • Fragile
  • Fuse rating specification
  • Type B, Applied Part
  • Dangerous voltage / shock hazard
  • Protective earth ground
  • Patient weight limit: 181 kg (400 lbs)

Intended Use
This product is intended to be used as a chair / table to provide positioning and support of patients during general examinations & procedures conducted by qualified medical professionals.

Electrical Requirements

  • Caution: When using high frequency surgical devices or endocardial catheters, do not use the drawer or upholstery heater. Failure to comply may result in electric shock or burns to the patient.
  • Electromagnetic Interference: This Midmark table is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and this table, refer to the Electromagnetic Compliance Statements per EN60601-1-2 available online at www.documark.com.
  • Authorized EU Representative:

Maintenance Cleaning
To clean the Barrier-Free Examination Table, follow these steps:

  1. Disconnect the table from the power source.
  2. Wipe down the surfaces with a mild detergent and water solution.
  3. Rinse the surfaces with clean water.
  4. Dry the surfaces thoroughly before reconnecting the table to the power source.

Preventative Maintenance
To ensure the optimal performance of the Barrier-Free Examination Table, perform the following preventative maintenance tasks:

  • Regularly inspect the table for any signs of damage or wear.
  • Tighten any loose screws or bolts.
  • Lubricate moving parts as necessary.

Calling for Service
If you require service for your Barrier-Free Examination Table, please provide the following information:

  • Model Number
  • Serial Number
  • Date of Purchase
  • Name of Owner / Facility
  • Name of Dealer
  • Dealer’s Phone Number
  • Midmark Authorized Service Company

FAQ

  1. Q: What is the weight limit for the Barrier-Free Examination Table?
    A: The weight limit for the table is 181 kg (400 lbs).

  2. Q: How often should I perform preventative maintenance on the table?
    A: It is recommended to perform preventative maintenance tasks on a regular basis, such as inspecting for damage or wear, tightening screws and bolts, and lubricating moving parts as necessary.

  3. Q: Where can I find the Electromagnetic Compliance Statements?
    A: The Electromagnetic Compliance Statements can be found online at www.documark.com. Use the FIND feature to locate document number 077-0501-00.

Barrier-Free Examination Table
To purchase a printed copy of this manual click on the “Place Order” button below.

  • For models:
    • 622
    • 623

Owner’s Product Identification

(The information below is required when calling for service)

Important Information

Safety Symbols

  • Caution
    Indicates a potentially hazardous situation which could result in injury if not avoided.

  • Equipment Alert
    Indicates a potentially hazardous situation which could result in equipment damage if not avoided.

  • Note
    Amplifies a procedure, practice, or condition.

This product has been evaluated with respect to electrical shock, fire & mechanical hazards only, in accordance with UL60601-1 and CAN/CSA C22.2 NO. 601.1. ****

Transportation / Storage Conditions

  • Ambient Temperature Range: …………………………+5°C to +38°C (+41°F to 100°F)
  • Relative Humidity …………………………………………10% to 90% (non-condensing)
  • Atmospheric Pressure …………………………………..500hPa to 1060hPa (0.49atm to 1.05atm)

Intended Use
This product is intended to be used as a chair / table to provide positioning and support of patients during general examinations & procedures conducted by qualified medical professionals.

Electrical Requirements

  • Use non-conductive material to insulate patient from metal portions of the table.
  • Consult operating instructions for the device before using in conjunction with drawer or upholstery heater.
  • Failure to comply may result in electric shock or burns to patient.

Electromagnetic Interference
This Midmark table is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and this table:

  • Remove interfering device from room
  • Plug table into an isolated circuit
  • Increase separation between table and interfering device
  • Contact Midmark if interference persists

Electromagnetic Compliance Statements per EN60601-1-2 are available online:
Go to: www.documark.com (Use the FIND feature to locate: 077-0501-00)
Authorized EU Representative
Countries in the EU should direct all questions, incidents, and complaints to Midmark’s Authorized EU representative listed below. :

  • Midmark EMEA Ltd

  • Beech House, First Floor, East Wing Ancells Business Park

  • Fleet

  • Hampshire   GU51 2UN

  • United Kingdom

    • Tel : + 44 (0) 1252 360 940

    • Fax : + 44 (0) 1252 360 941

Disposal of Equipment
At the end of product life, the table, accessories, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods.

Safety Instructions

Caution
Be sure that all personnel and equipment are clear of the table before activating any function. Failure to do so could result in personal injury.

  • At the table’s lowest height [18 in. (45.7 cm)], the clearance between the bottom of the drawer and the floor is approximately 3.5 in. (9 cm). Make sure patient (esp. feet) and all objects are clear of this area before lowering table.
  • If the table malfunctions, immediately release foot pedal, unplug the table power cord, and assist the patient from the table. If table continues to malfunction, call for service.
  • Failure to comply with these instructions may result in injury to patient and/or damage to equipment.

Operation

Table Up / Down Operation

Note
The table automatically stops at its maximum and minimum height.
To move the table Up or Down… Press and hold the appropriate button.

Equipment Alert
If the table’s weight limit is exceeded, you will hear a “beep” and the function will be disabled. If the problem occurs with a normal load, contact your service technician.MIDMARK-622-Barrier-Free-Examination-Table-
IMAGE-9

Back Section Operation – 622

To position the back section…

  • While holding the back section in place, squeeze the Back Release Handle (either side).
  • Move the back section.
  •  Release handle to lock back section in position.

MIDMARK-622-Barrier-Free-Examination-Table-IMAGE-10

Back Section Operation – 623

Note
The back section automatically stops at the top and bottom of its travel.
To position the back section… Press and hold the appropriate button.
Equipment Alert

If the table’s weight limit is exceeded, you will hear a “beep” and the function will be disabled. If the problem occurs with a normal load, contact your service technician. If the table’s weight limit is exceeded, you will hear a “beep” and the function will be disabled. If the problem occurs with a normal load, contact your service technician.

Home Function – 623 only

Note
The Home Function automatically lowers the table to 20” (50.8 cm). Press the Stop button at anytime to stop movement.
To activate the Home Function… Press and release the Home button.MIDMARK-622
-Barrier-Free-Examination-Table-IMAGE-13MIDMARK-622-Barrier-Free-Examination-Table-
IMAGE-14

Exam Assistant™ Drawer System

  • To use the drawer front as a shelf…

    • Pull drawer front down to release the magnetic latch.
  • Equipment Alert
    The maximum weight the shelf will support is 10 lbs (4.5 kg).

  • If drawer front folds past horizontal… Press two tabs and swing drawer front upward.

  • Equipment Alert
    If drawer front folds past horizontal, do not operate table.

Paper Roll & Tear Strap

  • Note
    • Up to four paper rolls (max.) may be stored under the back section.
  • Paper Roll Size (maximum):
    • 622 & 623 (-007 & -008)…………………………………… 21 in. long x 3.5 in. diameter
    • (53.3 cm x 8.9 cm)
    • 623 (-009 & -010) ……………………………………………. 19.7 in. long x 4.7 in. diameter
    • (50 cm x 12 cm)
      MIDMARK-622-Barrier-Free-Examination-Table-IMAGE-17

Stirrups

  • Caution
    Be sure the stirrups are locked in place before using. The stirrups will not support the patient’s entire weight.

  • To position the stirrups…

    • Pull the stirrup out, then unfold.
    • Lift the stirrup slightly, then move it left or right as desired.
    • Release stirrup to lock in position.

Footrest & Treatment Pan

Caution
Do not use footrest to support patient’s entire weight.

Drawer Heater (optional)

Note

  • The drawer heater switch illuminates when heater is ON.
  • The drawer heater warms the contents of the drawer to approximately 98°F (37°C).
  • To turn the drawer heater ON / OFF… Press & release the drawer heater switch.

Pelvic Tilt (optional)

MIDMARK-622-Barrier-Free-Examination-Table-IMAGE-21

Duplex Receptacle (not available on 230 volt models)
The duplex receptacle on the side of the table provides power for accessories used during medical procedures. There are two circuit breakers located under the seat section. If the receptacle’s maximum load is exceeded, the circuit breakers interrupt power to the receptacle.

  • Maximum Load: ……………………………………………………………………… 115 VAC, 5 amps
  • To reset the circuit breaker… Push circuit breaker switch.

Maintenance

Cleaning
Clean upholstery with 5% bleach/water solution.

  • Equipment Alert
    The upholstery is resistant to most medicinal-type stains, but may be damaged by solvents and dyes. Immediately remove any fluids spilled on the upholstery.

  • Clean the table weekly, wiping the painted metal and plastic surfaces with a clean,
    soft cloth, and mild cleaners. Periodic applications of common furniture wax will ease cleaning and maintain the finished luster of the table.

  • Preventive Maintenance
    Periodically inspect the following areas:

    • Power cord should be free of cuts or other visible damage.
    • All fasteners should be present and tightened securely.
    • All mechanical functions should operate properly.
  • Periodically lubricate the following areas to maintain quiet, smooth, operation:

    • Back hinge (use light machine oil)
    • Footrest slide (use household furniture wax)

Have a qualified service technician inspect your table every six months.

Calling For Service

  • Note
    Model / Serial Number information is required when calling for service.

  • Contact your Midmark Dealer, or log onto www.midmark.com to locate your nearest service provider. To contact Midmark directly:

  • 1-800-Midmark (1-800-643-6275) or 937-526-3662 8:00 am until 5:00 pm. Monday through Friday (EST)[excluding standard U.S. holidays

Specifications

Weights, Dimensions, Electrical Specifications

  • * Patient Weight (Maximum) ……………………………………….. 400 lbs (181.4 kgs)
    • Paper Roll (maximum size) : …………………………………….. (See Paper Roll & Tear Straps page)
  • Range of Motion &

    • Dimensions …………………………………………………………… (See Range of Motion & Dimensions page)
  • Weight of Table:
    [Weights listed are for 115V models. The 230V transformer adds 14.5 lbs (6.5 kg)]

    • 622 / 623 w/upholstery ………………………………………….. 325 lb (147 kg)
    • w/packaging & skid (no uph.) …………………………………. 375 lb (192.7 kg)
    • Upholstery w/packaging (shipped separately) ……….. 40 lbs (18.1 kg)
    • Power Cord(s) [115V models have two cords]: …………… 8 ft. (243.8 cm) long
    • Electrical Requirements : …………………………………………. [See Regulatory Compliance Charts]
    • Foot / Hand Control Voltag e: …………………………………….. 14 VAC, SELV (Safety Extra Low Voltage)
  • Duplex Receptacle (optional)

    • maximum load: ……………………………………………………… 115 VAC, 5A, 50/60 Hz

Fuses:

  • 622/623 (all):
    • F1 & F2 (on main PC board) ………………………………………………………. 10A, 250V, Type-T, 1/4″ x 1 1/4″
    • F3 (on main PC board) ………………………………………………………………… 5A, 250V, Type-T, 1/4″ x 1 1/4″
    • F4 (on main PC board) ………………………………………………………………… 187 mA, 250V, Type-T, 1/4″ x 1 1/4″
    • F5 (on main PC board) ………………………………………………………………… 4A, 250V, Type-T, 1/4″ x 1 1/4″
  • Models w/ drawer heater
    • distribution board fuses (2) …………………………………….. 800 mA, 250V, Type-T, 5 x 20mm
  • Models w/ upholstery heater
    • uph. heater PC board fuses (2) ……………………………….. 1/2 A, 250V, Type-T, 1/4″ x 1 1/4″
  • 623 (-009 & -010):
    • located next to IEC inlet (2)…………………………………….. 4A, 250V, Type-T, 5 x 20 mm
  • Duty Cycle:
    • Actuator motor run time : ………………………………………………. Intermittent Operation
    • [30 seconds ON / 5 minutes OFF]
    • Receptacle / Drawer Heater / Uph. Heater : ……………………… Continuous Operation
    • Classifications: ……………………………………………………….. Class 1, Type B Applied Part,
    • Protection against ingress of fluid s: ………………………… IPX0 [Foot Control only: IPX1]

Equipment not suitable for use in the presence of a flammable anesthetic mixture with air, or with oxygen, or nitrous oxide.

Regulatory Compliance Chart – 622 / 623

Fire Code Ratings: All upholstery complies with California Bureau of Home Furnishing Technical Bulletin 117  Optional upholstery is available that complies with California Bureau of Home Furnishing Technical Bulletin 1MIDMARK-622-Barrier-Free-Examination-Table-IMAGE-23

Range of Motion & Dimensions

m MIDMARK-622-Barrier-Free-Examination-Table-IMAGE-26

Warranty Information

SCOPE OF WARRANTY

  • Midmark Corporation (“Midmark”) warrants to the original retail purchaser that it will repair or replace components of the domestic and international medical products manufactured by Midmark (except for components not warranted under
  • “Exclusions”) that are defective in material or workmanship under normal use and service. Midmark’s obligation under this warranty is limited to the repair or replacement, at
  • Midmark’s option, of the applicable components. This limited warranty shall only apply to defects that are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. This warranty extends only to the first retail purchaser of a product and is not transferable or assignable.
  • APPLICABLE WARRANTY PERIOD
  • The applicable warranty period, measured from the date of delivery to the original user, shall be one (1) year for all warranted products and components.

OBTAINING WARRANTY SERVICE

  • Warranty service must be obtained through either Midmark or an authorized dealer in the Midmark product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at www.midmark.com; by phone at 1-800-MIDMARK; by facsimile at 1-800-365-8631; or by mail to Midmark
  • Corporation, 60 Vista Drive, Versailles, Ohio 45380.
  • It is the retail purchaser’s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser’s expense. It is also the retail purchaser’s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within thirty (30) days after purchase in order to obtain the benefits of this warranty.

EXCLUSIONS
This warranty does not cover, and Midmark shall not be liable, for the following:

  1. defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, tampering or failure to seek and obtain repair or replacement in a timely manner;
  2. products which are not installed, used, and properly cleaned and maintained as required in the Midmark “Installation” and/or “Installation/Operation Manual” for the applicable product;
  3. products considered to be of a consumable nature;
  4. accessories or parts not manufactured by Midmark;
  5. charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark;
  6. costs and expenses of routine maintenance and cleaning; and
  7. representations and warranties made by any person or entity other than Midmark.

EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER:

  • MIDMARK’S ONLY OBLIGATION UNDER THIS WARRANTY IS THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. MIDMARK SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR DELAYS, INCLUDING, BUT NOT LIMITED TO,
  • DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER AND EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND BENEFITS.
  • NO AUTHORIZATION
  • No person or firm is authorized to create or approve for Midmark any other obligation or liability in connection with the products.
  • WARRANTY DISCLAIMER
  • THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY IS
  • LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.
  • STATUTE OF LIMITATIONS
  • No action may be brought against Midmark for breach of this limited warranty, an implied warranty, if any, or for any other claim arising out of or relating to the products, more than ninety (90) days following expiration of the limited warranty period.
    https://manual-hub.com/

Midmark Corporation

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals