midmark 253 Ritter LED Examination Light User Guide
- June 9, 2024
- Midmark
Table of Contents
midmark 253 Ritter LED Examination Light User Guide
Product Information
Important Information
Safety Symbols
These symbols may appear on your equipment and/or in the manuals.
WARNING
Indicates a potentially hazardous situation which could result in serious
injury.
Caution
Indicates a potentially hazardous situation which may result in minor or
moderate injury. It may also be used to alert against unsafe practices.
Equipment Alert
Indicates a potentially hazardous situation which could result in equipment
damage.
Proper Shipping Orientation
Fragile
Keep Dry
Type B Applied Part
Manufacturer
Consult User Guide
Fuse Rating Specification
Power ON / OFF
Bright Light (Do not look directly into light)
Catalogue Number
Serial Number
Humidity Limit
Pressure Limit
Temperature Limit
Transportation / Storage Conditions
- Ambient Temperature Range: -22°F to 140°F (-30°C to +60°C)
- Relative Humidity: 10% to 90% (non-condensing)
- Atmospheric Pressure: 500 hPa to 1060 hPa
Before First Use
Remove protective film from lens… Pull tab to peel protective film from lens
Intended Use
The Ritter 253 provides focusable illumination for general examinations and
procedures performed by trained professionals in a healthcare environment.
Electromagnetic Interference
This product is designed and built to minimize electromagnetic interference
with other devices. However, if interference is noticed between another device
and this product:
- Remove interfering device from room
- Plug light into isolated circuit
- Increase separation between light and interfering device
- Contact Midmark if interference persists
Disposal of Equipment
At the end of product life, the light, accessories, and other consumable goods
may become contaminated from normal use. Consult local codes and ordinances
for proper disposal of equipment, accessories and other consumable goods.
WARNING
This product can expose you to chemicals including Antimony Oxide (Antimony
Trioxide), which is known to the state of California to cause cancer. For more
information go to www.p65warnings.ca.gov
Operation
Power ON / OFF
To connect power to the light…
A) Connect power cord to light housing.
B) Plug cord into properly rated receptacle.
Note: When power is connected, the lighthead will flash several times,
and the indicator light will illuminate.
To turn the light ON / OFF … Press the power button.
Note
The light has an automatic shutoff feature that turns the light OFF after two
hours. Refer to Automatic Shutoff Feature section for more information.
Automatic Shutoff Feature
The Automatic Shutoff Feature turns the light OFF two hours after the last
power button press.
Note
Lights are shipped from the factory with this feature disabled.
To enable the Automatic Shutoff Feature …
A) Press & hold the power button for 5 seconds.
B) Observe. The lighthead will flash three times indicating the feature
has been enabled.
Note: To disable this feature, repeat the procedure. The lighthead will
flash four times when this feature is disabled.
Light Pattern Adjustment
To adjust the size of the light pattern…
Rotate the lighthead clockwise / counterclockwise.
Maintenance
Fuse Replacement
To replace fuses…
A) Disconnect power cord from light housing.
B) Press tab & pull fuse holder out of cord inlet.
C) Replace fuses.
D) Push fuse holder into inlet until it locks in place.
Fuse Specifications:
1.6 amp, 250VAC, 5mm x 20mm
Type T, low breaking capacity IEC 127-2/3
Troubleshooting
Problem | Possible Cause | Correction |
---|---|---|
Light will not turn ON. (Power indicator light: OFF) | Power cord is not | |
connected. | Secure power cord connections. | |
Faulty fuse(s). | Replace fuses. (Refer to procedure in this manual) | |
Light will not turn ON. (Power indicator light: ON) | Lighthead or flex | |
arm malfunctioning. | Contact authorized Midmark service technician. | |
Light pattern will not adjust. | Lighthead malfunctioning. | Contact authorized |
Midmark service technician.
Light turns OFF by itself.| Automatic Shutoff Feature| Disable automatic
shutoff feature. (Refer to procedure in this manual)
Calling for Service
Note
Model / serial number information is required when calling for service.
If service is required, contact your authorized Midmark dealer.
To contact Midmark® directly:
1.800.MIDMARK (1.800.643.6275)
8:00 am until 5:00 pm Monday – Friday (EST)
midmark.com
Cleaning
Clean the painted metal and plastic surfaces using a clean soft cloth, and
mild cleaner. Disinfect your product with a solution of standard bleach and
water mixed 1 in 10 (10%) or chlorine based cleaners. Follow this with a clear
water rinse and thorough drying of material. See current CDC Guideline for
Disinfection and Sterilization in Healthcare Facilities.
Preventative Maintenance
Periodically inspect the following:
- Power cord should be free of cuts or other visible damage.
- All fasteners should be in place and tightened securely.
Have an authorized service technician inspect your equipment periodically.
Specification Chart
LED| Life: approximately 50,000 he (non-replaceable) per bulb
manufacturer
Light Pattern| Circular
Adjustable Spot Size @ Focal distance: 16″ (41 cm)| Diameter: 4″
(10 cm) to 12″ (30 cm)
Illumination @ Focal distance: 16″ (41 cm) Spot size: 4″ (10 cm)|
1,700 foot-candles / 18,298 lux
Color Temperature| 4,500K
Power Cord Length| 8 ft. (2.5 m)
Flex Arm Reach[from power source enclosure)| 54.5″(138 cm)
Flex Arm Rotation [at power source enclosure)| 140°
Electrical Rating| 115 VAC, 50/60 Hz, 100mA
230 VAC, 50/60 Hz, 60mA
Fuses| 1.6 amp, 250V, 5mm x 20mm, Type T low breaking capacity IEC 127-2/3
Regulatory Compliance| UL 60601-1 Rev. 26-Apr-06CAN/CSA C22.2 No.
60601-1:08Canadian Medical Device Regulations 50R/98-282 NFPA99 (applicable
to product requirements)
Classification| Class 1, Type B Applied Part
WARNING
Equipment is not suitable for use in the presence of a flammable anesthetic
mixture with oxygen, air, or nitrous oxide.
Clarification: Equipment is suitable for use in the presence of oxygen, air, or nitrous oxide.
Model Identification / Compliance Chart
Midmark® + Ritter® Medical Equipment (Tables, Chairs, Physician
Seating, Lights, Workstations and Sterilizers) Limited Warranty
SCOPE OF WARRANTY Midmark Corporation (“Midmark”) warrants to the original
retail purchaser that it will, at Midmark’s option, repair or replace
components of the domestic and international medical products manufactured by
Midmark (except for components not warranted under “Exclusions”) that are
defective in material or workmanship under normal use and service. The sole
remedy under this limited warranty is the repair or replacement, at Midmark’s
option, of the applicable components. This limited warranty shall only apply
to defects that are reported to Midmark within the applicable warranty period
and which are determined to exist upon examination by Midmark,. This warranty
extends only to the original retail purchaser of a prodct and is not
transferable or assignable. Replacement components or products may be used
and/or refurbished components or products, provided they are of like quality
and specifi cations as new components or products.
Midmark warrants to the original retail purchaser that during the applicable warranty period it will repair or replace software contained within the products manufactured by Midmark (except for those not warranted under “Exclusions”) if: (1) the media on which the software is furnished exhibits defects in material or workmanship under normal use; or (2) the software does not substantially conform to its published specifications.
APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of invoice to the original retail purchaser of the product and shall be one (1) year for all warranted products and components. QuickClean® Ultrasonic Cleaners are warranted for a period of three (3) years.
OBTAINING WARRANTY SERVICE Warranty service must be obtained through either Midmark or an authorized dealer in the Midmark product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at midmark.com; by phone at 1.800.MIDMARK or by mail to Midmark Corporation, 60 Vista Drive, Versailles, Ohio 45380. It is the retail purchaser’s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser’s expense. It is also the retail purchaser’s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within thirty (30) days after purchase in order to obtain the benefits of this limited warranty.
EXCLUSIONS: This limited warranty does not cover and Midmark shall not be liable for the following:
- Defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, negligent storage, tampering or failure to seek and obtain repair or replacement in a timely manner;
- Products which are not installed, used, and properly cleaned and maintained as required or recommended in the Midmark “Installation” and/or “Installation/Operation Manual” for the applicable product, including the specifi ed structural and operational environmental conditions and electrical requirements;
- roducts considered to be of a consumable or sterile nature;
- Accessories or parts not manufactured by Midmark;
- Charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark;
- Costs and expenses of routine maintenance and cleaning; and
- Representations and warranties made by any person or entity other than Midmark.
- Matching of color, grain or texture except to commercially acceptable standards;
- Changes in color caused by natural or artificial light;
- Custom manufactured products;
- Alterations or modifications to the product by any person or entity other than Midmark; and
- Products that would otherwise by covered under this limited warranty, but are acquired: (i) from a person or entity that is not Midmark or one of its authorized dealers; or (ii) from a Midmark dealer that is not authorized to sell the product at issue in the geographic territory where the purchaser is located, or is not authorized to sell the product at issue within the medical market.
SOFTWARE; WITH RESPECT TO SOFTWARE THAT IS A PRODUCT OR COMPONENT THEREOF, MIDMARK DOES NOT WARRANT THAT THE SOFTWARE: (1) IS ERROR FREE; (2) CAN BE USED WITHOUT PROBLEMS OR INTERRUPTIONS; OR (3) IS FREE FROM VULNERABILITY TO INTRUSION OR ATTACK BY VIRUSES OR OTHER METHODS.
EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER MIDMARK’S ONLY OBLIGATION UNDER THIS LIMITED WARRANTY IS THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. MIDMARK SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR DELAYS, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, LOSS OF DATA, DOWNTIME, COVER AND EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND BENEFITS. THIS DISCLAIMER SHALL SURVIVE ANY FAILURE OR ASSERTED FAILURE OF THE ESSENTIAL PURPOSE OF THIS LIMITED WARRANTY OR ITS REMEDIES SPECIFIED HEREIN. WARRANTY DISCLAIMER THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.
STATUTE OF LIMITATIONS No action may be brought against Midmark for breach of this limited warranty, an implied warranty, if any, or for any other claim arising out of or relating to the products, more than ninety (90) days following expiration of the limited warranty period.
NO AUTHORIZATION No person or fi rm is authorized to create or approve for Midmark any other obligation or liability in connection with the products.
Costumer Support
Midmark Corporation
60 Vista Drive
Versailles, OH 45380 USA
1.800.643.6275
1.937.526.3662
midmark.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>