Aeotec TriSensor 8 AEOEZWA045 Manual
- June 16, 2024
- Aeotec
Table of Contents
- Aeotec
- Aeotec TriSensor 8
- SKU: AEOEZWA045
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Node Information Frame
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Firmware-Update over the Air
- Association – one device controls an other device
- Configuration Parameters
- Parameter 3: Motion Untrigger Time
- Parameter 4: Motion Sensitivity
- Parameter 7: Motion Group Control (Group2)
- Parameter 8: Motion Group Value Setting
- Parameter 9: Motion Group Control Requirement
- Parameter 10: Over Heat Group Threshold (Group3)
- Parameter 11: Under Heat Group Threshold (Group4)
- Parameter 12: Over Light Group Threshold (Group5)
- Parameter 13: Under Light Group Threshold (Group6)
- Parameter 14: Low Battery Threshold
- Parameter 15: Threshold Check Enable/Disable
- Parameter 16: Temperature Threshold
- Parameter 17: Lux Threshold
- Parameter 18: Threshold Check Time
- Parameter 19: Sensor Limit Control
- Parameter 20: Temperature Upper Limit
- Parameter 21: Temperature Lower Limit
- Parameter 22: Lux Upper Limit
- Parameter 23: Lux lower limit level.
- Parameter 24: Temperature Scale
- Parameter 25: Automatic Interval Time
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aeotec
Aeotec TriSensor 8
SKU: AEOEZWA045
Quickstart
This is a
secure
Sensor
for
Europe.
To run this device please insert fresh *1 CR123A** batteries.
Please make sure the internal battery is fully charged.
If your Z-Wave gateway supports SmartStart, you can scan the QR code on the TriSensor 8 to automatically pair the sensor if your Z-Wave hub supports this.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Aeotec TriSensor 8 was developed to detect ambient values and movement and to transmit them with Z-Wave Plus. It is powered by Aeotec’s Gen8 technology. You can find out more about TriSensor 8 by following that link.” To see whether TriSensor 8 is known to be compatible with your Z-Wave system or not, please reference our Z-Wave gateway comparison listing. The technical specifications of TriSensor 8 can be viewed at that link.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
1. Make sure the device has been powered.
2. Press and hold the button for 12+ seconds, then release the action
button.”
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Placement Considerations.
”
There are some placement considerations when using the TriSensor 8 as a motion sensor. Above are some diagrams that show the distance at which the wall or ceiling installations can perform based on the height TriSensor 8 is installed, as well as the angle.
- Ceiling installation should have at least 3m height to the floor for the most optimal motion detection.
- Wall installation should have at least 2.5m height to the floor, angled downwards at 45 degrees.”
“
”
“
The longer detection range of the motion sensor is in the direction of the side of the battery.”
“
” ” Installation positioning advice:
- Avoid installing TriSensor 8 in locations nearby environmental changes such as air conditioners, fans, or heaters. Instead, install the TriSensor 8 on the opposite side of the room against environmental changes as these will greatly impact the temperature sensor if you wish to get the most accurate temperature change for the overall room.”
- Make sure to avoid installing TriSensor 8 nearby any metal, metal has a property that reflects wireless signals which can greatly impact the range of this sensor.
- Ensure that there are no objects or obstacles in front of the sensor lens which can impact the motion sensor tracking.
- Install TriSensor 8 pointed in the direction of the most foot traffic in the room.
“
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
- Set your Z-Wave hub to connect new Z-Wave devices.
- Tap the TriSensor 8″ action button 3x times within 1.5 seconds.”
- If prompted, scan the QR code or enter the 5-digit DSK code.”
Exclusion
1.” Set your Z-Wave gateway into Z-Wave unpair” (exclusion)” mode.
2. Tap the” action button 3x times within 1.5 seconds ; the” red” LED
will light up.
Product Usage
Power up TriSensor 8.
TriSensor 8 can only be battery-powered, you must first power up your TriSensor before you can pair it and use it in your Z-Wave network.”
“
Steps.
1. Remove the battery cover by sliding the Unlock button LEFT, then pull the cover off.
2. Insert 1x CR123A lithium batteries orientated according to the diagram within your sensor.”
Try inserting the batteries flat rather than at an angle.
WARNING: ” Not compatible with rechargeable CR123A batteries (3.6V).
3. You can close up the TriSensor 8 by placing the cover back on at an angle, but I would recommend doing this once you are done pairing the sensor to your Z-Wave network. So hold of on doing this so that you can reach the Action button on the TriSensor 8.”
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It
contains
information about the device type and the technical capabilities. The
inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:
Press button 3 times.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Press and hold the button for 3 seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Firmware-Update over the Air
This device is capable of receiving a new firmware ‘over the air’. The update
function
needs to be supported by the central controller. Once the controller starts
the update
process, perform the following action to confirm the firmware update:
You can find OTA Update by Aeotec.
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Lifeline |
---|---|---|
2 | 5 | Motion (Basic Set) |
3 | 5 | Over Heat (Basic Set) |
4 | 5 | Under Heat (Basic Set) |
5 | 5 | Over light (Basic Set) |
6 | 5 | Under Light (Basic Set) |
7 | 5 | Temperature (Multisensor) |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 3: Motion Untrigger Time
Timeout configuration set in second for TriSensor to send no trigger
status.
Size: 2 Byte, Default Value: 60
SettingDescription
30 – 3600 | seconds |
---|
Parameter 4: Motion Sensitivity
Set the sensitivity of TriSensor.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | disable |
---|---|
1 – 3 | Sensitivity |
Parameter 7: Motion Group Control (Group2)
Set control of other devices on group2 based on motion trigger
Size: 1 Byte, Default Value: 0
SettingDescription
0| Send BASIC_SET (0xFF) when motion is triggered to associated device Send
BASIC_SET (0x00) when motion is untriggered to associated device
---|---
1| Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when
motion is untriggered
2| Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion
untriggered
3| Send BASIC_SET (0x00) when motion is triggered, Nothing when motion
untriggered.
4| Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion
triggered.
5| Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion
triggered.
6| Send BASIC_SET (value is configured by parameter 8) when motion is
triggered to associated devices. Send BASIC_SET (value is configured by
parameter 8) when motion is untriggered.
Parameter 8: Motion Group Value Setting
_Set Basic Set value for Group2. The MSB will act as the basic set value when
motion trigger. The LSB will act as the basic set value when motion untrigger.
E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger,
BASICSET(0x00) will be sent when motion untrigger.
Size: 2 Byte, Default Value: 65280
SettingDescription
0 – 30000 | Value |
---|
Parameter 9: Motion Group Control Requirement
_Set threshold of Light/Lux when devices associated in group2 should be
triggered by motion. Associated device only receive BASICSET command when
light <= (this value).
Size: 2 Byte, Default Value: 30000
SettingDescription
0 – 30000 | Value |
---|
Parameter 10: Over Heat Group Threshold (Group3)
_Set threshold of temperature. Designed to control Air Conditioners or
temperature controllers ON or OFF. If measured temperature >= (this value,
Scale is determined by Param24) send BASIC_SET (0xFF) to associated devices.
If measured temperature < (this value) send BASICSET (0x00) to associated
devices. E.g. Value 239 means 23.9 C. Value 750 means 75.0 F.
Size: 2 Byte, Default Value: 270
SettingDescription
270 – 850 | “°C |
---|---|
806 – 1850 | “°F |
Parameter 11: Under Heat Group Threshold (Group4)
_Set threshold of temperature. Designed to control Air Conditioners or
temperature controllers ON or OFF. If measured temperature <= (this value,
Scale is determined by Param24) send BASIC_SET (0xFF) to associated devices.
If measured temperature > (this value) send BASICSET (0x00) to associated
devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F
Size: 2 Byte, Default Value: 155
SettingDescription
-100 – 155 | “°C |
---|---|
140 – 600 | “°F |
0 | disable |
Parameter 12: Over Light Group Threshold (Group5)
_Set threshold of Light/Lux. If measured light/lux >= (this value) send
BASIC_SET (0xFF) to associated devices. If measured light < (this value) send
BASICSET (0x00) to associated devices.
Size: 2 Byte, Default Value: 2000
SettingDescription
0 | disable |
---|---|
1 – 30000 | Lux |
Parameter 13: Under Light Group Threshold (Group6)
_Set threshold of Light/Lux. If measured light/lux <= (this value) send
BASIC_SET (0xFF) to associated devices. If measured light/lux > (this value)
send BASICSET (0x00) to associated devices.
Size: 2 Byte, Default Value: 100
SettingDescription
0 | disable |
---|---|
1 – 30000 | Lux |
Parameter 14: Low Battery Threshold
Configure low battery report threshold, sends low battery report via
notification and battery report when battery level drops under setting. Unit
%.
Size: 1 Byte, Default Value: 20
SettingDescription
10 – 50 | % |
---|
Parameter 15: Threshold Check Enable/Disable
__
Size: 1 Byte, Default Value: 0
SettingDescription
0 | disable |
---|---|
1 | enable |
Parameter 16: Temperature Threshold
__
Size: 1 Byte, Default Value: 30
SettingDescription
0 | disable |
---|---|
1 – 255 | Value x 0,1 |
Parameter 17: Lux Threshold
__
Size: 2 Byte, Default Value: 250
SettingDescription
0 | disable |
---|---|
0 – 10000 | Lux |
Parameter 18: Threshold Check Time
Set threshold check time in seconds.
Size: 2 Byte, Default Value: 900
SettingDescription
60 – 65535 | Time in seconds |
---|
Parameter 19: Sensor Limit Control
This value is bit mask. Used to enable/disable measurement reports for
various sensors that is more than the upper limit value or less than the lower
limit value. (1+2=3)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disable |
---|---|
1 | Temperature upper level |
2 | Lux upper level |
4 | Temperature lower level |
8 | Lux lower level |
Parameter 20: Temperature Upper Limit
Set upper limit level for temperature set in scale of 0.1. Scale is
determined by Param23. If (Current measurement) > (Upper Limit), then report
sensor.
Size: 2 Byte, Default Value: 280
SettingDescription
280 – 1000 | “°C |
---|---|
824 – 2120 | “°F |
Parameter 21: Temperature Lower Limit
Set lux upper limit level. If (Current measurement) > (Upper Limit), then
report sensor.
Size: 2 Byte, Default Value: 0
SettingDescription
-400 – 0 | “°C |
---|---|
-400 – 320 | “°F |
Parameter 22: Lux Upper Limit
Set Lux upper limit level. If (Current measurement) > (Upper Limit), then
report sensor.
Size: 2 Byte, Default Value: 1000
SettingDescription
0 – 30000 | Lux |
---|
Parameter 23: Lux lower limit level.
Set Lux lower limit level. If (Current Measurement) < (Lower limit), then
report sensor.
Size: 2 Byte, Default Value: 100
SettingDescription
0 – 30000 | Lux |
---|
Parameter 24: Temperature Scale
Set the scale for temperature when reports.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | “°C |
---|---|
1 | “°F |
Parameter 25: Automatic Interval Time
Interval time set in seconds to check the sensor report. Multilevel Sensor
Report will be sent when timeout
Size: 2 Byte, Default Value: 3600
SettingDescription
30 – 65535 | Time in seconds |
---|
Technical Data
Hardware Platform | EFR32ZG23 |
---|---|
EAN | 1220000017276 |
IP Class | IP IP20 |
Battery Type | 1 * CR123A |
Device Type | Sensor |
Firmware Version | 02.07 |
Z-Wave Version | 07.12 |
Z-Wave Product Id | 0371.0002.002d |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Ss Basic
- Application Status
- Sensor Multilevel
- Transport Service
- Association Grp Info
- Device Reset Locally
- Zwaveplus Info
- Supervision
- Configuration
- Alarm
- Manufacturer Specific
- Powerlevel
- Firmware Update Md
- Battery
- Wake Up
- Association
- Version
- Indicator
- Multi Channel Association
- Security
- Security 2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.