DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technology of a solid-state
microcomputer to provide precise temperature control.
Features:
- Battery powered (3 “AA” Energizer ® alkaline batteries included).
- Simultaneous heat and cool temperature storage
- LCD continuously displays set point and room temperature
- °F/°C convertibility
- Temperature range 45° to 90°F
- Standard five terminals for single or two-transformer systems
- B and O terminals for single stage heat pumps or damper operation
This thermostat is intended for use with a low voltage system; do not use this
thermostat with a line voltage system. If in doubt about whether your wiring
is millivolt, line, or low voltage, have it inspected by a qualified heating
and air conditioning contractor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and ordinances.
This control is a precision instrument, and should be handled carefully. Rough
handling or distorting components could cause the control to malfunction.
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power
to system, at main fuse or circuit breaker box, until installation is
complete.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause shock or fire hazard.
WARNING
Do not short out terminals on gas valve or primary control to test. Short or
incorrect wiring will damage thermostat and could cause personal injury and/or
property damage.
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
APPLICATIONS
For use with:
-
Standard heat/cool or heat only systems
-
Electric heat systems
-
Gas or oil fired systems
-
Gas systems with intermittent ignition devices (I.I.D.) and/ or vent dampers
-
Single-stage heat pump systems
-
Millivolt systems
DO NOT USE WITH: -
Multi-stage systems
-
Systems exceeding 30 VAC and 1.5 amps
-
3-wire zoned hydronic heating systems
INSTALLATION REMOVE OLD THERMOSTAT
- Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.
- Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
- Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.
- Disconnect the wires from old thermostat one at a time. DO NOT LET WIRES FALL BACK INTO THE WALL.
- Install new thermostat using the following procedures. ELECTRIC HEAT OR SINGLE-STAGE HEAT PUMP SYSTEMS
Read entire paragraph before setting electric heat switch. If you are unsure
of your application, contact a qualified serviceperson. If you have a single-
stage heat pump system, OR your system uses central electric heat, where the
blower is energized by a separate circuit through the fan relay (meaning that
the fan turns on immediately on call for heat), then the switch on the back of
the thermostat base must be moved to the “ELECTRIC” position (see fig. 1). If
the thermostat is energizing electric heat sequencers, the switch MUST remain
in the “GAS” position. If you must move the switch to the “ELECTRIC” position
(to the left), use a small screwdriver or pencil.
ATTACH THERMOSTAT BASE TO WALL
-
Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit. If necessary, move the electric heat switch (see ELECTRIC HEAT SYSTEMS, above).
-
Connect wires beneath terminal screws on base using appropriate wiring schematic (see figs. 3 through 10).
-
Place base over hole in wall and mark mounting hole locations on wall using base as a template.
-
Move base out of the way. Drill mounting holes.
-
Fasten base loosely to wall, as shown in fig. 2, using two mounting screws. Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If
you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase. -
Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.
BATTERY LOCATION
This thermostat requires 3 “AA” alkaline batteries to operate.
Batteries are installed in the thermostat at the factory with a battery tag to
prevent power drainage. You must remove the battery tag to engage the
batteries and provide power to the thermostat.
If the word BATTERY is displayed, the batteries are low and should be replaced
with fresh “AA” Energizer ® alkaline batteries.
To replace batteries, install the batteries along the top of the base (see
fig. 2). The batteries must be installed with the positive (+) ends to the
left.
CHECK THERMOSTAT OPERATION
If at any time during testing your system does not operate properly, contact a
qualified serviceperson.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
- Turn on power to the system.
- Move FAN switch to ON position. The blower should begin to operate.
- Move FAN switch to AUTO position. The blower should stop immediately.
Heating System
- Move SYSTEM switch to HEAT position. If the heating system has a standing pilot, be sure to light it.
- Press to adjust thermostat setting above room temperature. The heating system should begin to operate.
- Press to adjust temperature setting below room temperature. The heating system should stop operating.
Cooling System
This thermostat has a built-in short-term (5-minute) time delay.
This feature is activated after the compressor shuts down and the setpoint is
changed within the 5-minute period. During this 5-minute period, COOL will
flash on the display indicating that the thermostat has locked out the
compressor to allow head pressure to stabilize. This thermostat does not sense
AC power loss and therefore does not activate the short term compressor
protection feature when power is restored.
CAUTION
To prevent compressor and/or property damage, if the outdoor temperature is
below 50°F, DO NOT operate the cooling system.
- Move SYSTEM switch to COOL position.
- Press to adjust thermostat setting below room temperature. The blower should come on immediately on high speed, followed by cold air circulation
- Press to adjust temperature setting above room temperature. The cooling system should stop operating.
OPERATION
Before you begin using your thermostat, you should be familiar with its
features and with the display and the location and operation of the thermostat
buttons. Your thermostat consists of two parts: the thermostat cover and the
base. To remove the cover, gently pull it straight out from the base. To
replace the cover, line up the cover with the base and press gently until the
cover snaps onto the base.
THE THERMOSTAT BASE
The Thermostat Buttons and Switches Other than and , the following buttons and
switches are located behind the door on the bottom of the thermostat cover
(see fig. 11). Pull the door down to open it.
-
Red arrow) Raises temperature setting.
-
(Blue arrow Lowers temperature setting.
-
FAN switch (ON, AUTO).
-
SYSTEM switch (COOL, OFF, HEAT).
The Display -
HEAT is displayed when the SYSTEM switch is in the HEAT position. COOL is displayed (non-flashing) when the SYSTEM switch is in the COOL position. COOL is displayed (flashing) when the compressor is in lockout mode.
OFF is displayed when the SYSTEM switch is in the OFF position. -
Displays current temperature.
-
BATTERY is displayed when the 3 “AA” batteries are low and should be replaced. Nothing else will be displayed.
-
Displays current setpoint temperature (this is blank when SYSTEM switch is in the OFF position).
OPERATING FEATURES
Now that you are familiar with the thermostat buttons and display, read the
following information to learn about the features of the thermostat.
-
SIMULTANEOUS HEATING/COOLING STORAGE — You can enter both your heating and cooling setpoints at the same time. There is no need to reset the thermostat at the beginning of each season.
-
LOW BATTERY INDICATOR — If the 3 “AA” alkaline batteries are low and should be replaced, the display will be blank except for the word BATTERY. When the batteriesare low, pressing any button will cause the display to operate for ten seconds. After ten seconds, the display will be blank except for the word BATTERY. When the duration of a low battery condition exceeds four weeks, the setpoint is altered by 10 degrees to signal that the batteries must be replaced.
-
°F/°C CONVERTIBILITY— After ten seconds of no key activity, when the thermostat is in the temperature display adjustment mode, or 30 seconds after power up, pressing abd at the same time will switch the LCD temperature
display between Fahrenheit and Celsius. -
TEMPERATURE DISPLAY ADJUSTMENT — Your new thermostat has been accurately set in our factory. However, if you wish, you may adjust your new thermostat temperature display to match your old thermostat. This can be
accomplished (within a ±4° range) as follows:
1. Press abd at the same time within 30 seconds of applying power.
2. Press or to adjust the displayed temperature to your desired setting.
3. After setting your desired temperature, do not press any buttons for ten seconds. The thermostat will continue operating at the changed temperature setting.
SETTING THE THERMOSTAT
This thermostat is very easy to operate. Set the SYSTEM button to either HEAT
or COOL, then press or until the temperature you want to maintain is
shown on the right side of the display. If you want to turn the system off,
just move the SYSTEM switch to OFF. The FAN switch controls the fan operation.
When the FAN switch is set to AUTO, the fan will cycle with the furnace or air
conditioner. When the FAN switch is set to ON, the fan will run continuously,
regardless of SYSTEM switch position.
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
PART NO. 37-5410C
Replaces 37-5410B
9805
Printed in U.S.A.
Documents / Resources
|
WHITE-RODGERS 1F86-444 Non Programmable Electronic Digital
Thermostat
[pdf] Instruction Manual
1F86-444 Non Programmable Electronic Digital Thermostat, 1F86-444, Non
Programmable Electronic Digital Thermostat, Programmable Electronic Digital
Thermostat, Electronic Digital Thermostat, Digital Thermostat, Thermostat
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>