White Rodgers BP150 Line Voltage Programmable Thermostat User Guide

June 16, 2024
WHITE RODGERS

Line Voltage Programmable Thermostat
Installation Instructions & User Guide

BP150 Line Voltage Programmable Thermostat

White Rodgers BP150 Line Voltage Programmable
Thermostat For BP150, BP150C, BP125C,1E65-151

Congratulations on the purchase of your White-Rodgers ™ thermostat! Save these instructions for future use! Questions? Contact White-Rodgers TM  Customer Service at 1-877-654-9394

WARNING

Before installing and operating this product, the owner and/or installer must read, understand and follow these instructions and keep them handy for future reference. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this product. Moreover, the following instructions must be adhered to in order to avoid personal injuries or property damages, serious injuries and potentially fatal  electric shocks. All electric connections must be made by a qualified electrician, according to the electric and building codes effective in your region. Do NOT connect this product to a supply source other than 120 VAC or 240 VAC, and do  not exceed the load limits specified. Protect the heating system with the appropriate circuit breaker or fuse. You must regularly clean dirt accumulations on the thermostat. Do NOT use fluid to clean thermostat air vent. Do not install  thermostat in a wet place. However, installing it in insulated walls is allowed.
Note :
When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of  the actual product.
Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual.
The screen/LCD display shown as an example in this manual may be different from the actual screen/LCD display.

Description

This programmable electronic thermostat can be used to control electric heating units such as electric baseboards, convectors, or aero convectors. It keeps the temperature of a room at the requested set point with a high degree of  accuracy. This product is designed for installations with electrical current – with a resistive load – ranging from 1.25 A to 12.5 A (120/240 VAC). It possesses a user-friendly interface. Furthermore, it gives you the possibility to control the temperature of a room with great precision.
This thermostat is not compatible with the following installations :

  • Electrical current higher than 12.5 A with a resistive load (3000 W @ 240 VAC and 1500 W @ 120 VAC);
  • Electrical current lower than 1.25 A with a resistive load (300 W @ 240 VAC and 150 W @ 120 VAC); and
  • Central heating system.

Parts supplied:

  • one (1) thermostat;
  • wall mounting plate located at the back of the thermostat;
  • two (2) mounting screws;
  • two (2) solderless connectors suitable for copperwares.

Installation

Selection of the thermostat location
The thermostat must be mounted to a connection box on a wall facing the heating unit, at around 1.5 m (5 feet) above the floor level, on a section of the wall exempt from pipes or air ducts.
Do not install the thermostat in a location where temperature measurements could be altered. For example:

  • close to a window, on an external wall, or close to a door leading outside;
  • exposed directly to the light or heat of the sun, a lamp, a fireplace or any other heat source;
  • close or in front of an air outlet;
  • close to concealed ducts or a chimney; and
  • in a location with poor air flow (e.g. behind a door), or with frequent air drafts (e.g. head of stairs).

Thermostat mounting and connection

  1. Cut off power supply on lead wires at the electrical panel in order to avoid any risk of electric shock.
  2. Ensure that the air vents of the thermostat are clean and clear of any obstruction.
  3. Using a screwdriver, loosen the screw retaining the mounting base of the thermostat until it is loose (do not completely remove the screw).White Rodgers BP150 Line Voltage Programmable Thermostat - connection Then, remove the mounting base at the back of the thermostat by pushing it downwards and then towards you.
  4. Align and secure the mounting base to the connection box using the two screws supplied.
  5. Pass the wires from the wall through the opening on the mounting base and connect them using the supplied solderless connectors. When making the connection with aluminum wire, make sure that you are using connectors  identified CO/AL. Please note that the thermostat wires do not have polarity. Therefore, the way they are connected is not important.White Rodgers BP150 Line Voltage Programmable Thermostat - connection2White Rodgers BP150 Line Voltage Programmable Thermostat - connection3
  6. Place all the wires into the connection box.
  7. Align the little slots located on the top of the thermostat with those on the mounting base and secure the thermostat to the mounting base. Note that you can also position the  thermostat on the left or the right side of the junction box. Then, tighten the screw at the bottom of the unit.
  8. Turn on the power.
  9. Set the thermostat to the desired setting (see the following section).

Operation

White Rodgers BP150 Line Voltage Programmable Thermostat -
Operation

The programmable thermostat has three main operating modes: Manual ( ), Automatic ( ) and Preprogrammed ( ). The active mode is displayed at the bottom of the screen. The transition from one mode to another is done by pressing down the , button, out of any adjustment mode.
Note: it is impossible to change the operation mode when the Security mode is activated.
When first powered up, the thermostat is initially in degrees Celsius, in Preprogrammed mode (preprogram 5), and the Anticipated start mode is activated. The clock is adjusted to Saturday (12:00) and flashes to indicate that an  adjustment is necessary. The preprogram is effective immediately.
Adjustment of the hour and the day

To adjust the hour and the day:

  1. In any mode (Manual, Automatic or Preprogrammed), out of any adjustment mode, press down the button and release it.
  2. The current time mode (24H/12H) is displayed. Press down the or button to select the desired format. Press down the button to confirm your choice.
  3. The two hour digits flash. Adjust the hours using the and Press down the button to confirm your choice.
  4. The two minute digits flash. Adjust the minutes using the and buttons. Press down the button to confirm your choice.
  5. The day of the week flashes. Adjust using the and buttons. Press down the button to confirm your choice.

The adjustment is thus completed and the thermostat returns to normal operation.
It is possible to exit the hour and day adjustment mode at any time :

  • By pressing down the button.
  • By not pressing down any buttons during 1 minute.

In case of a power failure lasting less than 2 hours, the thermostat saves the adjustment of the hour and the day of the week. When the power is restored after an extensive failure, the hour will blink, indicating that it must be readjusted.

Ambient temperature
The figures displayed above the hour indicate the ambient temperature. It can be displayed in degrees Celsius or Fahrenheit (see “Display in degrees Celsius/ Fahrenheit”).
To adjust the set point, out of any adjustment mode, press down the button to increase the set point (it will blink), or the button to decrease it. Set points can only be adjusted by increments of 0.5°C (1°F). To quickly scroll through the set  point values, press and hold down the button. The minimum set point is 3°C (37°F), and the maximum set point is 30°C (86°F).
To return to the ambient temperature, do not press down any buttons for 3 seconds or press down both and buttons simultaneously. You can turn off the thermostat by lowering the set point below 3°C (37°F). The set point value displayed will be –.-, and heating system start up will be impossible.
Display in either degrees Celsius / Fahrenheit

The thermostat can display the ambient temperature and the set point in degrees Celsius (standard factory setting) or Fahrenheit.

  1. In any mode (Manual, Automatic or Preprogrammed), out of any adjustment mode, press down the button for 3 seconds and release it. The various icons and options appear and °C or °F icon flashes.
  2. Press down the button to  confirm your choice.
  3. Press down the or button to switch from degrees Celsius to Fahrenheit. Press down the button to confirm your choice.

The adjustment is thus completed and the thermostat returns to normal operation.
It is possible to exit the degrees Celsius/Fahrenheit adjustment mode at any time :

  • By pressing down the button.
  • By not pressing down any buttons during 1 minute.

In any case, the adjustment is saved.

Manual mode ( )
From the Manual mode, you can manually adjust the thermostat set point by pressing down the or button to increase the value, or to decrease it. To quickly scroll through the set point values, press and hold down the button. The standard factory set point adjustment is 21°C. From this mode, the screen displays the temperature, the heating power used, the hour and the day of the week.
Automatic mode ( )

From the Automatic mode, the thermostat adjusts the set points according to the programmed periods. If no data was entered, the thermostat acts the same way as from the Manual mode and the standard factory set point adjustment is 21°C. It is always possible to manually adjust the set point using the or button. The selected set point will be effective until one period is programmed, which represents an hour and a day of the week. Note that if the set point is lowered to  off (–.-), the programming will not be effective. It is possible to program 4 periods a day during the week and 4 periods a day during the weekend, which means that the set point can change automatically up to 4 times a day. The period  order is not important.
From this mode, the screen displays the temperature, the heating power used, the hour, the day of the week and the current programmed period number ( displayed on the right-hand side of the hour).
Programming procedure of the Automatic mode
Programming the Automatic mode can be done in the Automatic mode or the Manual mode.

  1. Out of any adjustment mode, press down the button during 3 seconds and release it. It then enters into the programming of period 1 of the 5 days of the week. The 5 days of the week (L/M, M/T, M/W, J/T, V/F), the period 1 ( ) and the associated programming (hours and set point) are displayed. Note that the time displays –:– and the set point displays –.– if there is no programming for the period.
    Note: if no programming is required for the period, simply press down the button. It then automatically switches to the next adjustment period.

  2. The two hour digits of the period flash and can then be adjusted with the and   buttons. Confirm the adjustment using the   button.

  3. The two minute digits of the period flash. Use the and buttons to adjust by intervals of 15 minutes. Confirm the adjustment by pressing down the button.

  4. The set point temperature of the period is flashing. Adjust the set point using the and buttons. Confirm your selection by pressing down the button.

  5. The programming of this period is over. The programming of the next period is displayed and you return to step 2.

  6. At the end of the programming of the 4 periods of the week days, you enter into the programming period 1 of the two days of the weekend. The two days of the weekend (S/S, D/S), the period 1 and the associated programming  (hours and set point) are displayed. The programming of the weekend periods is made in the same manner as for the periods of the week days (steps 2 to 5).

At the end of the programming period 4 of the weekend, the programming is completed and the thermostat returns to normal operation.
It is possible to exit the Automatic mode’s programming at any time :

  • By pressing down the button.
  • By not pressing down any buttons during 1 minute.

In any case, all programming is saved.
Erasing of the programming
When programming the Automatic mode, it is possible to delete a programming period.

  1. Enter into the programming of the Automatic mode and reach the period, as described in the previous section.
  2. When the period is displayed, simultaneously press down the and buttons to erase the programming. The time of the period displays –:– and the set point displays –.- to indicate that the programming is erased.
  3. Then, exit the programming mode as described in the previous section.

Preprogrammed mode ( )

The Preprogrammed mode allows a quick and easy preprogram of the thermostat. 18 preprograms (01 to 18) are defined in factory and easily accessible. This mode gives you the possibility to quickly program the thermostat using commonly used preprograms.

As from the Automatic mode, it is possible at any time to manually adjust the set point. This set point will be effective until the next set point change anticipated by the preprogram. Note that if the set point is lowered to off (–.-), the  programming will not be effective. From this mode, the screen displays the temperature, the heating power used, the hour, the day of the week and the number of the preprogram period (   displayed on the right-hand side of the hour).
This mode is initially activated when the power is turned on for the first time, with the program #5.

Selection of the Preprogram

See section 5 (Preprogram) to choose one of the 18 preprograms. The Quick selection section allows a choice based on 3 criteria: the number of hours you sleep, the time you wake up and the time you come home. The Detailed preprograms section gives a detailed schedule of all preprograms.
To select the preprogram :

  1. Access the Preprogrammed mode (if required) by pressing down the button until the display shows .
  2. Out of any adjustment mode, press down the button during 3 seconds until the preprogram number (01 to 18) blinks at the right-hand side of the hour.
  3. Choose the preprogram number by pressing down the and buttons. Confirm by pressing down the button.
    It is possible to exit the selection of the preprogram at any time:
    • By pressing down the button.
    • By not pressing down any buttons during 1 minute. In any case, the selection is saved.

View of the preprogram
It is possible to view the current preprogram. However, it is impossible to modify a preprogram.

  1. Access the Preprogrammed mode (if required) by pressing down the button until the display shows .
  2. Out of any adjustment mode, simultaneously press down the and button and release.
  3. The period 1 icon ( ) flashes and the days of the week are displayed to indicate that you are visualizing the days of the week’s period 1. Press down the and buttons to select the period to view.
    It is possible to exit the view of the preprogram at any time :
    • By pressing down the button.
    • By not pressing down any buttons during 1 minute.

Anticipated start
This mode enables the room to reach the selected temperature at the programmed hour. In fact, the thermostat estimates the delay required to reach the set point of the next period at the programmed hour. This delay is obtained by the observation of the temperature variations in the room and the results obtained during the preceding anticipated starts. That way, the results should be increasingly precise day after day. The icon will blink when the anticipated start of the next period will begin.
If the set point is changed manually when this mode is in progress, the anticipated start of the next period is canceled.
To activate or deactivate the anticipated start :

  1. In any mode (Manual, Automatic or Preprogrammed), out of any adjustment mode, press down the button for 3 seconds and release it. The various icons and options appear and °C or °F icon flashes.
  2. Press down the or button to select the icon (indicated by its flashing). Press down the button to confirm your choice.
  3. All icons disappear except the con that continues to flash. Press down the or button to activate or deactivate the Anticipated start (indicated by the icon that turns on or off). Press down the button to confirm your choice.

The adjustment is thus completed and the thermostat returns to normal operation.
It is possible to exit the Anticipated start adjustment mode at any time :

  • By pressing down the button.
  • By not pressing down any buttons during 1 minute.

In any case, the adjustment is saved.
Frost-free warning
The icon is displayed when the temperature set point is between 3°C (37°F) and 5°C (41°F). A minimum temperature will be maintained to ensure frost control.
Security mode
It is possible to impose minimum and maximum temperature set points by activating this mode. Then, it becomes impossible to exceed the maximum set point and go below the minimum set point, regardless of the current mode. When the Security mode is activated, any change in operation mode (Manual, Automatic or Preprogrammed) or any change in programming (Automatic mode) or preprogram (Preprogrammed mode) is impossible.
Procedures to activate the Security mode
To activate the Security mode, you must be in the desired mode (Manual, Automatic or Preprogrammed), and you must have completed the programming (Automatic mode) or selected the desired preprogram (Preprogrammed more).

  1. In any mode (Manual, Automatic or Preprogrammed), out of any adjustment mode, press down the button for 3 seconds and release it. The various icons and options appear and °C or °F icon flashes.
  2. Press down the or button to select the icon (indicated by its flashing). Press down the button to confirm your choice.
  3. All icons disappear except the icon that continues to flash. Press down the or button to activate the Security mode (indicated by the icon that turns on). Press down the button to confirm your choice.
  4.  L___ is displayed instead of the hours and the adjustment of the minimum set point flashes. Press down the or button to adjust the minimum set point temperature. The adjustment can range from –.- (Heating off) to 30°C by  intervals of 0.5°C (or 86°F by intervals of 1°F). Press down the button to confirm your selection.
  5. H___ is displayed instead of the hours and the adjustment of the maximum set point flashes. Press down the or button to adjust the maximum set point temperature. The adjustment will be between the minimum set point  previously selected and 30°C by intervals of 0.5°C (or 86°F by intervals of 1°F). Press down the button to confirm your selection.

The activation of the Security mode is thus completed and the thermostat returns to normal operation.
It is possible to exit the Security mode adjustment at any time :

  • By pressing down the button.
  • By not pressing down any buttons during 1 minute.

Note: if the adjustment of minimum and maximum set points is not completed, Security mode will not be activated.
Procedures to deactivate the Security mode

  1. To deactivate the Security mode, start by cutting off the thermostat power at circuit breaker and wait at least 30 seconds.
  2. Turn the thermostat power back on and the icon will blink for a maximum of 5 minutes.
  3. Press down the button for 3 seconds and release it. The various icons and options appear and °C or °F icon flashes.
  4. Press down the or button to select the icon (indicated by its flashing). Press down the button to confirm your choice.
  5.  All icons disappear except the icon that continues to flash. Press down the or button to deactivate the Security mode (indicated by the icon that turns off). Press down the button to confirm your choice.
    The deactivation of the Security mode is thus completed and the thermostat returns to normal operation.

Fan mode
When the thermostat is used to control a heating system equipped with a fan, the Fan mode must be activated. This mode prevents the system to continuously start and stop, which could cause fan failure. The Fan mode is not activated by default.
The status of this mode is indicated on the display by the icon.
To activate or deactivate the Fan mode and / or adjust the minimum operating time:

  1. In any mode (Manual, Automatic or Preprogrammed), out of any adjustment mode, press down the button for 3 seconds and release it. The various icons and options appear and °C or °F icon flashes.
  2. Press down the or button to select the icon (indicated by its flashing). Press down the button to confirm your choice.
  3. All icons disappear except the icon that continues to flash. Press down the or button to activate or deactivate the Fan mode (indicated by the icon that turns on or off). Press down the button to confirm your choice.
  4. If the Fan mode is deactivated, the thermostat returns to normal operation. If it is activated, the minimum operating time in seconds blinks (90 seconds by default).
  5. Press down the or button to adjust the minimum operating time if desired, from 90 to 30 seconds, in intervals of 30 seconds. Press down the button to confirm your choice. The thermostat will return to its normal operation.

It is possible to exit the Fan mode adjustment at any time :

  • By pressing down the button.
  • By not pressing down any buttons during 1 minute.

In any case, the adjustment is saved.
Parameters saving and power failures
The thermostat saves some parameters in a non-volatile memory to be able to recover them after being shut off (a power failure, for example). These parameters are the operation modes (Manual, Automatic or Preprogrammed), the programming of the Automatic mode, the preprogram selection, the current set point, the Celsius/ Fahrenheit display, the Fan mode, the minimum operating time in Fan mode, the Security mode, the minimum and maximum set points  in Security mode, the Anticipated start, the time mode (24h/12h), the day, the hour and the Nightlight mode.=
Backlight (models BP150, BP150C only)
By default, the backlight turns on when pressing down a button and turns off after 15 seconds of inactivity.
Nightlight mode (models BP150, BP150C only)
You can activate the Nightlight mode to permanently turn on the backlight. To activate or deactivate this mode, you must simultaneously press both and buttons for 3 seconds until the backlight blinks. Release the buttons. The Nightlight mode will be activated (or deactivated if it was previously activated).

Heating Power Indicator

The level of power used to maintain the temperature at the set point is expressed as a percentage indicated by the number of bars in the thermometer displayed. The heating power used is displayed as follows:

Troubleshooting

Problem Solution
The thermostat is hot. In normal operating conditions, the thermostat

housing can reach nearly 40°C / 100°F at maximum load. That is normal and will not affect the effective operation of the thermostat.
Heating is always on.| Check if the thermostat is properly connected. Refer to the installation section.
Heating does not run even if the thermostat indicates it is on.| Check if the thermostat is properly connected. Refer to the installation section.
The display does not turn on.| Check if the thermostat is properly connected. Refer to the installation section. Check the power supply at the electrical panel. Check if the heating unit has a switch. If so, ensure that this switch is turned on.
The display turns off a few minutes and then turns on again.| The thermal protection of the heating unit has opened due to overheating. Check if the heating unit is in good condition of operation and that clearance around the unit is according to the manufacturer’s specifications.
The display has low contrast when heating is on.| The load is lower than the minimum load. Install a heating unit that is within the load limits of the thermostat.
The displayed ambient temperature is incorrect.| Check the presence of an air stream or a heat source near the thermostat, and correct the situation.
The display indicates E1, E2, E3 or E4.| Faulty thermostat. Contact the customer service.
**
Weak luminosity of the display.**| Possibility of a bad contact. Check thermostat wiring. Refer to the installation section.

N.B. If you are unable to solve the problem after having verified these points, please contact our customer service department at 1-888-725-9797

Preprograms

Quick selection

8 hours of sleep

Wake up time:| 6am| 7am| 8am
Hour at which you come back from work:| 4pm| 1| 4| 7
5pm| 2| 5*| 8
6pm| 3| 6| 9
9 hours of sleep

Wake up time:| 6am| 7am| 8am
Hour at which you come back from work:| 4pm| 10| 13| 16
5pm| 11| 14| 17
6pm| 12| 15| 18

  • preprogram by default
    Detailed preprograms
    8 hours of sleep

pre-prog

| Monday-Friday| Saturday-Sunday
---|---|---
P1 (Wake up)| P2 (Leaving time)| P3 (Come back time)| P4 (Sleep)| P1 (Wake up)| P2 (Sleep)
1| 6am| 8am| 4pm| 10pm| 6am| 10pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
2| 6am| 8am| 5pm| 10pm| 6am| 10pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
3| 6am| 8am| 6pm| 10pm| 6am| 10pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
4| 7am| 9am| 4pm| 11pm| 7am| 11pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
5| 7am| 9am| 5pm| 11pm| 7am| 11pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
6| 7am| 9am| 6pm| 11pm| 7am| 11pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F

7

| 8am| 10am| 4pm| 0am| 8am| 0am
---|---|---|---|---|---|---
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F

8

| 8am| 10am| 5pm| 0am| 8am| 0am
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
9| 8am| 10am| 6pm| 0am| 8am| 0am
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F

9 hours of sleep

pre-prog

| Monday-Friday| Saturday-Sunday
---|---|---
P1 (Wake up)| P2 (Leaving time)| P3 (Come back time)| P4 (Sleep)| P1 (Wake up)| P2 (Sleep)
10| 6am| 8am| 4pm| 9pm| 6am| 9pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
11| 6am| 8am| 5pm| 9pm| 6am| 9pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
12| 6am| 8am| 6pm| 9pm| 6am| 9pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
13| 7am| 9am| 4pm| 10pm| 7am| 10pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
14| 7am| 9am| 5pm| 10pm| 7am| 10pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
15| 7am| 9am| 6pm| 10pm| 7am| 10pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
16| 8am| 10am| 4pm| 11pm| 8am| 11pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
17| 8am| 10am| 5pm| 11pm| 8am| 11pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F
18| 8am| 10am| 6pm| 11pm| 8am| 11pm
21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F| 21°C / 70°F| 16.5°C / 62°F

Technical Specifications

Supply voltage :
120/208/240 VAC, 50/60 Hz
Minimum electrical current with a resistive load :
1.25 A
150 W @ 120 V
260 W @ 208 V
300 W @ 240 V
Maximum electrical current with a resistive load :
12.5 A
1500 W @ 120 V
2600 W @ 208 V
3000 W @ 240 V
Temperature display range :
3°C to 40°C (37°F to 99.5°F)
Temperature display resolution :
0.5°C (0.5°F)
Temperature set point range:
3°C to 30°C (37°F to 86°F)
Temperature set point increments :
0.5°C (1°F)
Storage temperature :
-40°C to 50°C (-104°F to 122°F)

For Installation Help
1-877-654-9394
White-Rodgers.com
White-Rodgers
8100 West Florissant Avenue
St. Louis, MO 63136
© 2012 Printed in Canada

Documents / Resources

| White Rodgers BP150 Line Voltage Programmable Thermostat [pdf] User Guide
BP150 Line Voltage Programmable Thermostat, BP150, Line Voltage Programmable Thermostat, Voltage Programmable Thermostat, Programmable Thermostat, Thermostat
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WHITE RODGERS User Manuals

Related Manuals