DOMETIC CFF45 Compressor Fridge Freezer Installation Guide
- June 16, 2024
- Dometic
Table of Contents
CFF45 Compressor Fridge Freezer
Product Information
Specifications
- Product Name: MOBILE COOLING CFF
- Model: CFF45
- Type: Compressor Fridge/Freezer
- Power Supply: 12/24 V DC, 100 – 240V~AC
Safety Instructions
-
WARNING! Failure to obey these warnings could
result in death or serious injury.- Electrocution hazard
- Fire hazard
- Health hazard
- Explosion hazard
-
CAUTION! Failure to obey these cautions could
result in minor or moderate injury.- Electrocution hazard
- Health hazard
Scope of Delivery
- Cooler (Quantity: 1)
- Connection cable for DC connection (Quantity: 1)
- Connection cable for AC connection (Quantity: 1)
- Carry handle, consisting of (Quantity: 2):
- Lid latches (Quantity: 2)
- Operating manual (Quantity: 1)
Intended Use
The cooling device is suitable for cooling food and can be used
in vehicles, boats, and for camping purposes. It is designed to be
operated from a DC on-board power supply of a vehicle or boat, a DC
auxiliary battery, or from an AC power supply. Please note that
this product is only suitable for the intended purpose and any
other use is not allowed. Dometic does not accept liability for any
loss, damage, or injury incurred due to other than the intended
use.
Function Description
The cooler can chill products, keep them cool, and freeze them.
It utilizes a low maintenance refrigerant circuit with a compressor
for efficient and fast cooling. The generous insulation and
powerful compressor ensure effective cooling. The cooler is
portable and easy to carry.
Scope of Functions
The cooler has the following functions:
- Chilling products
- Keeping products cool
- Freezing products
Operating and Display Elements
-
ON/OFF: Switches the cooler on or off when the
button is pressed for between one and two seconds. -
POWER: Status indication LED lights up green
when the compressor is on, orange when the compressor is off,
flashes orange when the display is switched off automatically due
to low battery voltage, and flashes red when the device is switched
on but not ready for operation. -
Display: Shows the information and can be used
to decrease or increase values by pressing once. -
Connection Sockets:
- Socket 1: 12/24 V DC connection
- Socket 2: 100 – 240V~AC connection
- Socket 3: N/A
- Socket 4: N/A
FAQ
Q: What is the power supply for the cooler?
A: The cooler can be powered by a 12/24 V DC connection or a 100
– 240V~AC connection.
Q: Can the cooler freeze products?
A: Yes, the cooler is capable of freezing products.
MOBILE COOLING CFF
EN Compressor Fridge/Freezer
Operating manual
CFF 45
© 2021 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual belong to Dometic Sweden AB. All rights are reserved.
CFF45
Explanation of symbols
Please read these instructions carefully and follow all instructions,
guidelines, and warnings included in this product manual in order to ensure
that you install, use, and maintain the product properly at all times. These
instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions,
guidelines, and warnings carefully and that you understand and agree to abide
by the terms and conditions as set forth herein. You agree to use this product
only for the intended purpose and application and in accordance with the
instructions, guidelines, and warnings as set forth in this product manual as
well as in accordance with all applicable laws and regulations. A failure to
read and follow the instructions and warnings set forth herein may result in
an injury to yourself and others, damage to your product or damage to other
property in the vicinity. This product manual, including the instructions,
guidelines, and warnings, and related documentation, may be subject to changes
and updates. For up-to-date product information, please visit
documents.dometic.com, dometic.com.
Contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .3 2 Safety instructions . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3 Scope
of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .7 4 Intended use . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 5
Function description . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .8 6 Operation . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7
Cleaning and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 23 8 Troubleshooting . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 9 Warranty . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 27 10 Disposal . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 11 Technical
data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 28
1 Explanation of symbols
! WARNING! Safety instruction: Indicates a hazardous situation that, if not
avoided, could result in death or serious injury.
! CAUTION! Safety instruction: Indicates a hazardous situation that, if not
avoided, could result in minor or moderate injury.
A NOTICE! Indicates a situation that, if not avoided, can result in property
damage.
EN
3
Safety instructions
I NOTE Supplementary information for operating the product.
CFF45
2 Safety instructions
! WARNING! Failure to obey these warnings could result in death or serious
injury.
Electrocution hazard
· Do not operate the cooling device if it is visibly damaged.
· If this cooling device’s power cable is damaged, it must be replaced to
prevent safety hazards.
· This cooling device may only be repaired by qualified personnel. Improper
repairs can lead to considerable hazards.
Fire hazard
· When positioning the device, ensure the supply cord is not trapped or
damaged.
· Do not locate multiple portable socket-outlets or portable power supplies at
the rear of the device.
Health hazard
· This device can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the device in a safe way and understand the hazards involved.
· Children shall not play with the device.
· Cleaning and user maintenance shall not be made by children without
supervision.
· Children aged from 3 to 8 years are allowed to load and unload cooling
devices.
Explosion hazard
· Do not store any explosive substances such as spray cans with a flammable
propellant in the cooling device.
4
EN
CFF45
Safety instructions
! CAUTION! Failure to obey these cautions could result in minor or moderate
injury.
Electrocution hazard
· Before starting the cooling device, ensure that the power supply line and
the plug are dry.
· Disconnect the cooling device from the power supply before each cleaning
and maintenance after every use
Health hazard
To avoid contamination of food, please respect the following instructions:
· Please check if the cooling capacity of the device is suitable for storing
the food or medicine you wish to cool.
· Food may only be stored in its original packaging or in suitable containers.
· Opening the cooling device for long periods can cause significant increase
of the temperature in the compartments of the device.
· Clean regularly surfaces that can come in contact with food and accessible
drainage systems.
· If the device is left empty for long periods: Switch off the device.
Defrost the device. Clean and dry the device. Leave the lid open to
prevent mould developing within the device.
A NOTICE! Damage hazard · Check that the voltage specification on the type
plate corresponds to that of the energy supply.
· Only connect the cooling device as follows: With the DC connection cable
to a DC power supply in the vehicle Or with the AC connection cable to an AC
power supply
· Never pull the plug out of the socket by the cable.
· If the cooling device is connected to a DC outlet: Disconnect the cooling
device and other power consuming devices from the battery before connecting a
quick charging device.
· If the cooling device is connected to a DC outlet: Disconnect the cooling
device or switch it off when you turn off the engine. Otherwise you may
discharge the battery.
EN
5
Safety instructions
CFF45
· The cooling device is not suitable for transporting caustic materials or
materials containing solvents.
· The insulation of the cooling device contains flammable cyclopentane and
requires special disposal procedures. Deliver the cooling device at the end of
its life-cycle to an appropriate recycling center.
· Do not use electrical devices inside the cooling device unless they are
recommended by the manufacturer for the purpose.
· Do not place the cooling device near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.).
· Risk of overheating! Ensure at all times that there is a minimum of 50 mm
ventilation on all four sides of the cooling device. Keep the ventilation area
free of any objects that could restrict the air flow to the cooling
components. Do not place the cooling device in closed compartments or areas
with none or minimal air flow.
· Ensure that the ventilation openings are not covered.
· Do not fill the inner container with ice or fluids.
· Never immerse the cooling device in water.
· Protect the cooling device and cables against heat and moisture.
· The device shall not to be exposed to rain.
6
EN
CFF45
3 Scope of delivery
1
12/24 V DC
100240 V AC
Scope of delivery
1
32x
3
4
Item 1 2 3 4
Quantity Description
1
Cooler
1
Connection cable for DC connection
1
Connection cable for AC connection
2
Carry handle, consisting of:
· 2 holders
· 1 handle
· 4 fastening screws
· 1 allen wrench
1
Operating manual
EN
7
Intended use
CFF45
4 Intended use
The cooling device is suitable for cooling food. The cooling device is
suitable for use in vehicles or on boats.
The cooling device is designed to be operated from a DC on-board power supply
of a vehicle or boat, a DC auxiliary battery or from an AC power supply.
The cooling device is suitable for camping use.
The cooling device is intended to be used in household and similar
applications such as · staff kitchen areas in shops, offices and other working
environments · farm houses · clients in hotels, motels and other residential
type environments · bed and breakfast type environments · catering and similar
non-retail applications
This product is only suitable for the intended purpose and application in accordance with this instruction. Any other use, deviating from the intended use, is not allowed! Dometic accepts no liability for any loss, damage or injury incurred, directly or indirectly due to other than the intended use.
5 Function description
The cooler can chill products, keep them cool as well as freeze them. A low
maintenance refrigerant circuit with compressor provides the cooling. The
generous insulation and powerful compressor ensure efficient and fast cooling.
The cooler is portable.
The cooler can withstand a short-term inclination of 30°, for example on
boats.
8
EN
CFF45
Function description
5.1 Scope of functions
· Power supply with priority circuit for connecting to the AC mains · Three-
level battery monitor to protect the vehicle battery
switches off automatically at low battery voltage · Display with temperature
gauge in °C and °F · Temperature setting: With two buttons in steps of 1 °C (2
°F) · Display dimming function with 3 brightness levels · Removable wire
basket · Removable carrying handles
5.2 Operating and display elements
Lid latches 2
Operating panel
3
12 3 4
°
5
67
Item Description
1 ON OFF
Explanation
Switches the cooler on or off when the button is pressed for between one and
two seconds
EN
9
Function description
CFF45
Item Description 2 POWER “P”
3 ERROR 4 5 SET
6 DOWN 7 UP +
Explanation
Status indication LED lights up green:
Compressor is on
LED lights up orange:
Compressor is off
LED flashes orange:
Display switched off automatically due to low battery voltage
LED flashes red:
Device is switched on but not ready for operation
Display, shows the information
Selects the input mode Temperature setting Celsius or Fahrenheit display Set battery monitor Set brightness of display
Press once to decrease the value
Press once to increase the value
Connection sockets
4
1
2
3
4
100 – 240V~AC
12 – 24V DC
Item Description 1 Connection socket AC voltage supply 2 AC fuse holder 3 DC fuse cover 4 Connection socket DC voltage supply
10
EN
CFF45
6 Operation
Operation
6.1 Before initial use
I NOTE Before starting your new cooler for the first time, you should clean it
inside and outside with a damp cloth for hygienic reasons (please also refer
to the chapter “Cleaning and maintenance” on page 23).
Mounting the handles
5
1
2x
2
1
The handles are enclosed unassembled. If you wish to attach the handles,
proceed as follows: Assemble a handle by putting two holders (1) and a handle
(2) together. Fasten the holders with the enclosed screws in the holes
provided.
EN
11
Operation Opening or removing the lid 6
A
CFF45
B 2.
To open the lid, unlatch (A). The lid can be opened from either side.
To remove the lid, unlatch both sides at the same time (B)
Lid stop position
8
A
B
The lid has a built-in stop position (A). Do not force the lid past the built-
in stop (B).
A NOTICE! DAMAGE HAZARD If the lid has been forced too far, follow the steps
described in the chapter “The lid has been forced past the built-in stop” on
page 26.
12
EN
CFF45
Operation
Removing the basket
A NOTICE! DAMAGE HAZARD! Removing the basket with the lid open may scratch the lid and deform the basket. We recommend to remove the lid (fig. 6) before removing the basket (fig. 9).
9
Selecting the temperature units
Temperature display units can be switched between Celsius and Fahrenheit as
follows:
Switch on the cooler. Press the “SET” button twice (fig. 3 5, page 9). Use the
“UP +” (fig. 3 7, page 9) or “DOWN ” (fig. 3 6, page 9) buttons to
select Celsius or Fahrenheit.
The selected temperature unit then appears in the display for a few seconds.
The display flashes several times before it returns to the current
temperature.
6.2 Saving energy
· Choose a well ventilated location which is protected from direct sunlight. ·
Allow warm food to cool down first before placing it in the cooling device to
keep cool. · Do not open the cooling device more often than necessary.
EN
13
Operation
CFF45
· Do not leave the cooling device open for longer than necessary. · If the
cooler has a basket: For optimal energy consumption, position the basket
according to its position on delivery. · On a regularly basis, make sure the
lid seal still fits properly. · Defrost the cooler once a layer of ice forms.
· Avoid unnecessarily low temperatures.
6.3 Connecting the cooler
Connecting to a battery (Vehicle or boat) The cooler can be operated with 12 V
or 24 Vg.
A NOTICE! DAMAGE HAZARD Disconnect the cooler and other consumer units from
the battery before you connect the battery to a quick charging device.
Overvoltage can damage the electronics of the device.
For safety reasons the cooler is equipped with an electronic system to prevent
polarity reversal. This protects the cooler against short-circuiting when
connecting to a battery.
Using the fused DC plug
A NOTICE! DAMAGE HAZARD For protection of the device the DC cable supplied
includes a fuse inside the plug. Do not remove the fused DC plug. Only use the
DC cable supplied.
Plug the DC connection cable (fig. 1 2, page 7) into the DC voltage socket of
the cooler (fig. 4 3, page 10).
Connect the connection cable to a DC power outlet.
14
EN
CFF45
Operation
Connecting to an AC power supply (e.g. in the home or office)
D DANGER! ELECTROCUTION HAZARD Failure to obey these warnings will result in
death or serious injury. · Never handle plugs and switches with wet hands or
if you are standing on a wet surface. · If you are operating your cooler on
board a boat from a AC power supply, you must install a residual current
circuit breaker between the AC power supply and the cooler. Seek advice from a
trained technician.
The coolers have an integrated multi-voltage power supply with priority
circuit for connecting to an AC voltage source. The priority circuit
automatically switches the cooler to AC operation if the device is connected
to an AC power supply, even if the DC connection cable is still attached.
When switching between the AC power supply and the battery supply, the red LED
may light up briefly.
Plug the AC connection cable (fig. 1 3, page 7) into the AC voltage socket of
the cooler (fig. 4 1,page 10).
Connect the connection cable to an AC power outlet.
EN
15
Operation
CFF45
6.4 Using the battery monitor
The device is equipped with a multi-level battery monitor that protects your
vehicle battery against excessive discharging when the device is connected to
the on-board DC supply.
If the cooler is operated when the vehicle ignition is switched off, the
cooler switches off automatically as soon as the supply voltage falls below a
set level. The cooler will switch back on once the battery has been recharged
to the restart voltage level.
A NOTICE! DAMAGE HAZARD When switched off by the battery monitor, the battery will no longer be fully charged. Avoid starting repeatedly or operating current consumers without longer charging phases. Ensure that the battery is recharged.
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and “MED” (see the following table).
Battery monitor mode
LOW
MED
HIGH
Switch-off voltage at 12 V
10.1 V
11.2 V
11.8 V
Restart-voltage at 12 V
11.4 V
12.2 V
12.6 V
Switch-off voltage at 24 V
21.5 V
24.1 V
24.6 V
Restart voltage at 24 V
23.0 V
25.3 V
26.2 V
The battery monitor mode can be selected as follows:
Switch on the cooler.
Press the “SET” button three times (fig. 3 5, page 9).
Use the “UP +” (fig. 3 7, page 9) or “DOWN ” (fig. 3 6, page 9) buttons to
select the battery monitor mode.
Display will be as follows: Lo (LOW), Ed (MED), Hi (HIGH)
The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I NOTE When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery, the
battery monitor mode “LOW” will suffice.
16
EN
CFF45
Operation
6.5 Using the cooler
A NOTICE! OVERHEATING HAZARD Ensure at all times that there is sufficient
ventilation so that the heat that generated during operation can dissipate.
Ensure that the ventilation slots are not covered. Make sure that the device
is sufficiently far away from walls and other objects so that the air can
circulate.
Place the cooler on a firm foundation. Make sure that the ventilation slots
are not covered and that the heated air can dissipate. We recommend keeping a
gap of at least 50 mm around ventilation holes.
I NOTE Place the cooler as shown (fig. 1, page 7). If you operate the cooler
in a different orientation it can be damaged.
Connect the cooler (see chapter “Connecting the cooler” on page 14).
A NOTICE! EXCESSIVELY LOW TEMPERATURE HAZARD Ensure that the only those
objects are placed in the cooler that are intended to be cooled at the
selected temperature.
Press the “ON/OFF” button (fig. 3 1, page 9) for between one and two seconds.
The LED “P” lights up (fig. 3 2, page 9). The display (fig. 3 4, page 9)
switches on and shows the current temperature.
The cooler starts cooling the interior.
I NOTE When operating from a battery, the display switches off automatically
if the battery voltage is low. The LED “P” flashes orange.
EN
17
Operation
CFF45
Latching the cooler lid Close the lid. Press the latch (fig. 2, page 9) down, until it latches in place audibly.
I NOTE When latching the lid, ensure that both latch side pins are fully engaged to ensure a good lid seal. One latch may engage slightly before the other. If the lid is not closed equally at both sides, press until a second click is heard.
6.6 Setting the temperature
Press the “SET” button once (fig. 3 5, page 9).
Use the “UP +” (fig. 3 7, page 9) and “DOWN ” (fig. 3 6, page 9) buttons to
select the cooling temperature.
The cooling temperature appears in the display for a few seconds. The display
flashes several times and then the current temperature is displayed again.
18
EN
CFF45
Operation
6.7 Setting the display brightness
The display brightness can be dimmed for low ambient light conditions. To set
the dimming level of the display proceed as follows:
Switch on the cooler.
Press the “SET” button four times (fig. 3 5, page 9).
Use the “UP +” (fig. 3 7, page 9) or “DOWN ” (fig. 3 6, page 9) buttons to
set the brightness of the display.
Display will be as follows: d0 (default), d1 (medium), d2 (dark)
The display shows the set mode for several seconds. The display flashes twice
before it returns to the current temperature.
I NOTE · The factory setting of brightness of the display is d0 (default). · If a fault occurs, the brightness automatically reverts to brightness d0 (default). After troubleshooting the set brightness is reactivated.
6.8 Switching off the cooler
Empty the cooler. Switch the cooler off. Pull out the connection cable.
If you do not want to use the cooler for a longer period of time: Leave the lid slightly open. This prevents odor build-up.
EN
19
Operation
CFF45
6.9 Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the
evaporator. This reduces the cooling capacity.
A NOTICE! DAMAGE HAZARD Never use hard or pointed tools to remove ice or to
loosen objects which have frozen in place.
To defrost the cooler, proceed as follows: Take out the contents of the cooler. If necessary, place them in another cooling device to keep them cool. Switch off the device. Leave the lid open. Wipe off the defrosted water.
6.10 Replacing the AC fuse
D DANGER! ELECTROCUTION HAZARD Failure to obey this warning will result in
death or serious injury. Disconnect the power supply and the connection cable
before you replace the device fuse.
Disconnect the power supply to the device. Remove the connection cable. Pry
out the fuse insert (fig. 4 2, page 10) with a screwdriver. Replace the
defective glass fuse with a new one that has the same type and rating
(4 A, 250 V). Press the fuse insert back into the housing. Reconnect the power
supply to the device.
20
EN
CFF45
Operation
6.11 Replacing the device DC Fuse
Disconnect the power supply to the device. Pry out the fuse cover (fig. 4 3,
page 10) to access the fuse. Reverse the fuse cover and use the hook to remove
the fuse. Replace the defective fuse with a new fuse of the same type
(Automotive Stand-
ard blade fuse, 10 A). Re-fit the fuse cover. Reconnect the power supply to
the device.
6.12 Replacing the DC plug fuse
0
1
22 33
Unscrew the contact pin housing (3) from the plug (1).
Replace the defective fuse (2) with a new fuse of the same type and rating
(3AG, Fast Acting, 10 A).
Re-assemble the plug in reverse order.
EN
21
Operation
6.13 Replacing the light PCB
a 1.
2.
3.
Disconnect the power supply to the device. Pry out the transparent cover with
a screwdriver (1). Unscrew the PCB mounting screws (2). Pull out the plug from
the PCB (3). Replace the defective light PCB with a new one. Fit new PCB using
reverse of removal instructions. Press the transparent cover back into the
housing. Reconnect the power supply to the device.
CFF45
22
EN
CFF45
Cleaning and maintenance
7 Cleaning and maintenance
! WARNING! ELECTROCUTION HAZARD Failure to obey this warning could result in death or serious injury. Always disconnect the device from the power supply before you clean and service it.
A NOTICE! Damage hazard · Never clean the cooler under running water or in
dish water. · Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.
Occasionally clean the device interior and exterior with a damp cloth.
Make sure that the air inlet and outlet vents on the device are free of any
dust and dirt, so that heat can be released and the device is not damaged.
EN
23
Troubleshooting
8 Troubleshooting
CFF45
Fault
Possible cause
Suggested remedy
Device does not function, LED does not glow.
No voltage present in the connected power outlet.
Plugged in DC power outlet: In most vehicles the ignition must be turned on
before power will be supplied to the DC power outlet.
Plugged in AC power outlet: Try using another plug outlet.
One of the device fuses is defective.
Replace the defective device fuse, see chapter “Replacing the AC fuse” on page 20 or chapter “Replacing the device DC Fuse” on page 21.
The integrated mains adapter is defective.
This can only be repaired by an authorised repair center.
The device does not Defective compressor. This can only be repaired by an
cool (plug is inserted,
authorised repair center.
“POWER” LED is lit).
The device does not cool (plug is inserted, “POWER” LED flashes orange, display is switched off).
Battery monitor is set too high.
Battery voltage is too low.
Select a lower battery monitor setting. Test the battery and charge it as needed.
24
EN
CFF45
Troubleshooting
Fault
Possible cause
Suggested remedy
When operating from the DC outlet:
The ignition is on and the device is not working and the LED is not lit.
The DC outlet is dirty. This results in a poor electrical contact.
If the plug of your cooler becomes very warm in the DC outlet, either the DC outlet must be cleaned or the plug has not been assembled correctly.
The fuse of the DC plug Replace the fuse in the DC plug, see
has blown.
chapter “Replacing the DC plug fuse” on
page 21.
The device DC fuse has Replace the defective fuse, see chapter
blown.
“Replacing the device DC Fuse” on
page 21.
The vehicle fuse has blown.
Replace the vehicle’s DC outlet fuse. Please refer to your vehicle’s operating manual.
The display shows an error message (e.g. “Err1”) and the appliance does not cool.
The appliance has switched off due to an internal fault.
This can only be repaired by an authorised repair center.
EN
25
Troubleshooting
8.1 The lid has been forced past the built-in stop
b A
CFF45
B
Support the lid with one hand (A). Hold the latch down with the other hand
(B).
! CAUTION! HEALTH HAZARD Failure to obey this caution could result in minor or
moderate injury. Beware pinching your thumb while closing the lid.
A NOTICE! DAMAGE HAZARD! Failure to observe this instruction can cause the lid
to break off.
Close the lid as far as possible without pinching your thumb, while still
holding the latch down, to keep it from breaking.
The lid should now be approximately at the angle shown (fig. b). Remove the
hand from the latch (B), and continue closing the lid all the way.
I NOTE The hinges may release from the correct position during the final
closing action. Reposition the lid as follows: Operate the latches on both
sides of the lid simultaneously. Lift and reposition the lid.
26
EN
CFF45
Warranty
A NOTICE! Damage hazard · Never clean the cooler under running water or in
dish water. · Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.
Occasionally clean the device interior and exterior with a damp cloth.
Make sure that the air inlet and outlet vents on the device are free of any
dust and dirt, so that heat can be released and the device is not damaged.
9 Warranty
Comprehensive warranty details for this product are included in the separate
Warranty Certificate. For service or warranty assistance, please contact the
manufacturer via details on the back of this operating manual.
For warranty and repair processing, please have the following information
available: · A copy of the proof of purchase · A reason for the claim or
description of the fault
10 Disposal
Place the packaging material in the appropriate recycling waste bins, wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
EN
27
Technical data
11 Technical data
CFF45
Connection voltage:
Rated current:
Cooling capacity: Total volume: Climate class: Ambient temperature:
Refrigerant: Refrigerant volume: CO2 equivalent: Global warming potential
(GWP): Dimensions (W x H x D) in mm (including handles): (W x H x D) in mm
(with handles removed): Weight:
CFF 45 12/24 Vg 100 to 240 Vw 12 Vg: 8.6 A 24 Vg: 3.8 A 240 Vw: 0.41 A +10 °C
to 18 °C (+50 °F to 0 °F)
44 l N, T +16 °C to +43 °C +60 °F to +110 °F R134a 43 g 0.061 t
1430
715 x 475 x 398 590 x 475 x 398
18.9 kg
I NOTE If the ambient temperature is above +32 °C (+90 °F), the minimum temperature cannot be attained.
28
EN
CFF45 Test/certificates:
This product contains fluorinated greenhouse gases. The cooling unit is
hermetically sealed.
Technical data
EN
29
DOMETIC Australia PO Box 2495 Burleigh BC QLD 4220 Ph: 1800 21 21 21 (Mon-Fri
8:00am to 5:00pm AEST) Email: qldservice@dometic.com.au
AUS 1800 21 21 21 qldservice@dometic.com.au
4445103433 2021-04-09
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>