CHWARES 3040063-CS02 Small Ultrasonic Jewelry Cleaner Instruction Manual
- June 16, 2024
- CHWARES
Table of Contents
Instruction Manual
ULTRASONIC CLEANER
GZ- CS02
Please read the operating instructions carefully before using this
product, and store it properly after reading for future reference.
Safety and Precautions
-
Before using the product, please read the instructions carefully and keep it for future reference.
-
Do not disassemble and assemble products except for professionals.
-
Do not plug in the power supply before adding water, and do not exceed the Max Water Line to avoid overflow.
-
Do not touch the plug with wet hands to prevent electric shock.
-
Do not rinse the whole product with water to prevent electric shock.
-
Repeated cleaning can make things cleaner. The best interval between two cleanings is 3 minutes.
-
Do not use this product if you are sleeping or dozing.
-
If the cable for adapter is damaged, stop using and contact the after-sales service to get a new cable.
-
After immersion of the whole machine, the machine should not be directly connected to the power supply or start working, which may lead to machine failure or electric shock.
-
The adapter should be used with the power of AC 100-240V.
Using with different power specifications may cause problems such as machine failure, electric shock or fire. -
When a socket is used together with other appliances, a fire may occur due to overheating.
-
The power plug should be well plugged in the socket. If the plug is not fully plugged in, it may cause fire because of electric shock or heat.
-
The failure plug, loose socket, etc. shall not continue to use.
Unauthorized connection or processing of power cable, excessive bending or deforming of cable crushed by overweight is no allowed because it may cause fire or electric shock. -
Do not use in ares freezing or nearby fire, it may cause machine failure or damage.
-
Keep away from dampness, dust, splashing and direct sunlight to prevent fire or electric shock.
-
It is not allowed to install in the inclined position or place heavy objects on it, which may lead to performance degradation and damage of the machine.
-
Using water of excessive temperature (above 60°C or below 10°C) may cause machine failure or damage.
-
If there is any abnormal sound or burning smell, please disconnect the power immediately and contact the after-sales service.
Warning
- The sunglasses with color coating is not suitable for cleaning in ultrasonic cleaner. If you are not sure with the specification of your glass, please consult your optical store.
- Jewelry containing natural stones such as jade, agate, etc, or jewelry with crushing diamonds fixed by glue, is not suitable for cleaning in ultrasonic cleaner.
- When cleaning your watch, please make sure your watch is waterproof.
Components and Parameters
01 Indicator light
02 Function key
03 Control panel| 04 Basket
05 Lid
06 Water tank| 07 Main body
08 Supporting foot
09 Silica gel pad
---|---|---
Product Name : Ultrasonic cleaner
Power : 15W
Voltage : 12V
Capacity : 600ml
Ultrasonic Frequency : 40kHz
Product Material : ABS+304 stainless steel + silica gel
Product Size: 215x102x77(mm)
Product Suitability Scope
| Office supplies
Rulers,brushes, scissors, etc.
---|---
| Daily necessities
Toothbrushes, brushes, razors, etc.
| Tableware
Metal tableware, ancient coins, metal accessories, etc.
| Spectacles
Sunglasses, myopia glasses, presbyopia glasses,etc.
Note: If cleaning glasses,the lenses should be facing up to prevent
scratching.
| Jewelry & Watch
Rings, necklaces,bracelets, earrings and watch, etc.
Product Operation Method
-
Open the lid and place the cleaning items in stainless steel tank.
Note: lf cleaning glasses,the lenses should be facing up to prevent scratching.Note:Starting the machine without adding water will cause damage. -
Add water to stainless steel tank.
The cleaning part of the object must be completely immersed in water, but the working water level should not exceed the Max Water Line.
-
Close the lid, connect the adapter to the machine first. Then connect the adapter to the power supply, the indicator lightsup the white light, and the cleaning mode can be selected according to the material of the articles to be cleaned.
-
Press the function button lightly to start work and complete the cleaning process within the default time. In the default cleaning process, press the function button if you need to stop.Note:To avoid overheating of internal components, the protection program is set up.
When triggered, the white-light flashes.
It can be restarted only after the white light stops flashing.
-
After cleaning, disconnect the power supply, open the lid, take out the articles and rinse them with clean water.
Note: After cleaning, pour out the water and dry the stainless steel basin for easy use next time.
Simple Troubleshooting
Problem | Cause Analysis | Maintenance Measures |
---|
Pressing “Function Key” does not get respond and the indicator does not turn
on.| Is the adapter connected correctly?| Connect the adapter correctly.
Is the adapter damaged?| Contact vendors for after-sales service.
Things don’t get clean after cleaning.| Insufficient cleaning time?| Extend
cleaning time.
No detergent added?| Add a little detergent.