CHWARES KS-34XL Digital Kitchen Scale User Manual

June 14, 2024
CHWARES

CHWARE-LOGO

CHWARES KS-34XL Digital Kitchen Scale

CHWARE- KS-34XL-Digital-Kitchen-Scale-PRODUCT

Function Diagram

  1. On/Off
  2. Weighing Units Conversion
  3. Counting Overall Weight and Pieces
  4. Tare Weight
  5. Charging Port (Micro USB)
  6. LCD Display

CHWARE- KS-34XL-Digital-Kitchen-Scale-FIG- \(1\)

General Operation

CHWARE- KS-34XL-Digital-Kitchen-Scale-FIG- \(2\)

  1. Place the scale on a hard flat surface.
  2. Press the to turn on the scale. Make sure the display reads “0.0”.
  3. Tap to select the measuring unit, which will show on the top of the display.
  4. Place your item on the scale.
  5. Wait for the reading on the display to stabilize.
  6. When you’re done, reset the scale by removing all items from the scale. If the display doesn’t read “0.0”, press to reset the weight to zero.

ON/OFF
Press the [ 0 /ON/OFF] button to turn on the power, and the LCD screen will show “HELLO” and then 0.00 or 0.0 the scale is available to use now.

Setting the Shut Off time:

  • Under weighing status, press the [T /TARE/ZERO] button and hold until displays the “60” Press [M/MODE] to select the “120” or “180” (seconds) for auto shut off, and choose “O” for manual shut off.
  • After setting the shut-off time, press [ 0/0N/OFF] it will show “PASS” the setting completed. The default auto power-off time is 1 80 seconds.

(M/MODE] /Weighing Units Conversion
Under weighing status press the [M/MODE] button to change the weighing units to 9 different units G.CT.DWT. OZT.OZ.GN.LB.TL.ML. choose the one you need. The default unit is G.

(T/TARE/ZERO]

  • Press the [T/TARE/ZERO] button to delete the weighing record, and the LCD screen will show “0.0” or “0.00”
  • Place a tray slowly on the panel, and press the [T /TARE/ZERO] button the weight of the tray will be removed, and “0.0” or “0.00” will be displayed Slowly add the items to the tray to obtain just the weight of the contents.

(P/PCS] /Counting Features
Make sure all items are of uniform weight for the counting feature to work.

  • Press and hold the [P/PCS] button until you see the word “PCS” appear on the screen and a sample count displayed.
  • Press the [M/MODE] button to choose a sample count. The available sample count is 25. 50. 60. 75. 100. and place the items the same as the sample count on the panel, then press the [P/PCS] button to confirm the sampling.
  • Put all the items on the panel and press [P/PCS] to count the overall quantity.
  • During the counting, press the buttons [M/MODE] and [P/PCS] to switch between the weight and pieces, so you can get the weight and quantity at the same time.

Caution : Before the counting work, make sure you have put the items to the panel or you have chosen the sample count and then put the items.

M/MODE] /Calibration

Calibration is NOT required before first use.
Only calibrate if the scale is not weighing properly.

  • Under weighing status, press and hold the [M/MODE] button” for a few seconds display will show the default calibration weight or the previous record. If you don’t have the same calibration weight press the [M/MODE] button again to choose the other weights there are several weights for options choose the one you have After confirming the calibration weight press the [ON/OFF] button and it will show “CAL” the required calibration weight will be displayed.
  • Place the required calibration weight on the panel and press the [ON/OFF] button again the LCD screen will show “PASS” and calibration is completed. Remove the calibration weight to use the scale.

Please try to use the maximum calibration weight to ensure the accuracy of the scale.

Rechargeable Version

USB Charging
When the USB charger is plugged in, the battery icon on the LCD screen flashes continuously to indicate that it is charging. Once the battery is fully charged, the battery icon is no longer displayed and the unit will automatically switch off. After the automatic switch-off, simply dial out the charging port.

Note : Do not use the fast charging head to avoid damaging the device. If you purchase the battery version please ignore this.

Troubleshooting

The primary reasons for inaccuracy or malfunction are low battery, incorrect calibration, overload, or operating on an unstable surface. This scale is a precious instrument and should be handled with the utmost care and caution.

  • [DISPLAY] Elimination of errors
  • [OUT2] Calibration again.
  • [EEEE] Immediately remove overweight items to avoid causing damage to your scale.
  • [UN2T] Use the scale in a more stable position.
  • [LO] Low voltage, please charge it or replace it with new batteries.

ADVICE FOR USE & CARE

  1. Clean the scale with a slightly damp cloth. DO NOT immerse the scale in water or use chemical corrosive cleaner. Keep the scale in a cool dry place.
  2. All plastic parts should be cleaned immediately after contact with fats, spices, vinegar, and strongly flavored/colored foods. (Avoid contact with acids citrus juice.)
  3. Always use the scale on a solid, flat surface, and keep the scale unmoved when weighing.
  4. This product is a precision instrument, please handle it with care, Do not strike. shake or drop the scale.
  5. Keep away from high temperature, do not strip the scale arbitrarily.
  6. If fails to turn on, please check whether the battery power is low.
  7. Don’t abandon it as family garbage, please send this scale to the electronic equipment recycle station.
  8. Designed for family use only, not for commercial use.

Question or Concerns?
chwares [email protected]

Made in China

Documents / Resources

| CHWARES KS-34XL Digital Kitchen Scale [pdf] User Manual
KS-34XL Digital Kitchen Scale, KS-34XL, Digital Kitchen Scale, Kitchen Scale, Scale
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CHWARES User Manuals

Related Manuals