SCHRACK BZH 14111 Digital 1 Channel Astro Daily Timer User Manual
- June 16, 2024
- SCHRACK
Table of Contents
SCHRACK BZH 14111 Digital 1 Channel Astro Daily Timer
Product Information
Specifications
- Battery: CR 2032
- Technical data :
- 10 years power reserve
- Supply voltages : 230 V, 50/60 Hz
- Switching capacity : 16 A / 250 V~ at cos=1
- Contact material : AgSnO2
- Type of protection: IP 20
- Mode of operation : 1 BSTU
- Degree of contamination: 2
- Rated surge voltage : 4 kV
- Standard: DIN EN 60730-1 / DIN EN 60730-2-7
- (230V) CFL LED: 2000W
- (230V) 200W : 9 mm 1 – 4 mm2 0,8 Nm
Product Usage Instructions
Initial Operation
To start using the product, follow these steps:
- Make sure there is a power supply.
- Press the “WAKE UP WITH OK” button to activate the device.
- Use the “Prog Program” button to set up the desired settings.
- Press the “Astro On” or “Astro Off” buttons to turn on or off the astro mode.
Manual Switching
You can manually switch the device on or off by following these steps:
- Press the “Manual” button.
- Select the desired mode by pressing the corresponding button (e.g., “Astro On”, “Astro Off”).
Setting Astro Mode
To set up the astro mode, follow these steps:
- Press the “Astro On” or “Astro Off” button to activate or deactivate the astro mode.
- For more advanced settings, refer to the “SET Date – Time” section.
SET Date – Time
To set the date and time for astro mode, follow these steps:
- Press the “SET Date – Time” button.
- Use the buttons to adjust the desired date and time.
- For more advanced settings, refer to the “Offset” section.
Offset
You can set an offset for the astro mode by following these steps:
- Press the “Offset” button.
- Adjust the offset using the buttons (maximum offset is +/- 90 min).
FAQ
- What is the maximum offset for astro mode?
- The maximum offset for astro mode is +/- 90 minutes.
- What are the technical specifications of the device?
- The device has a power reserve of 10 years, operates at a supply voltage of 230V with a switching capacity of 16A / 250V~, and is protected with IP 20. It meets the standard DIN EN 60730-1 / DIN EN 60730-2-7.
- Can the device be used for security relevant tasks?
- No, the device is not qualified for security relevant tasks such as emergency doors or fire protection equipment.
Connection
Battery
- 230 V, 50/60 Hz
- 16 A / 250 V~ at cosϕ=1
- AgSnO2
- IP 20
- –30T55
- 1 BSTU
- 2
- 4 kV
- DIN EN 60730-1 / DIN EN 60730-2-7
Technical data
- Supply voltages
- Switching capacity
- Contact material
- Type of protection
- Ambient temperature
- Mode of operation
- Degree of contamination
- Rated surge voltage
- Standard
(230V) 2000W LED
CFL (230V) 200W
DIN-rail product
DIN-rail product: The device fits for the particular use of the following tasks : Illumination of private and industrial areas, street and shop-window lightening, regulation of air conditioning, motors, pumps, plants and machinery as well as to simulate presence etc. Operate the device in a dry room only! The device is not qualified for security relevant tasks such as emergency doors, fire protection equipment.
The installation and assembly of electrical equipment must be only carried out only by a skilled Person!
Otherwise fire danger or danger of an electric shock exists!
Disconnect the mains power supply prior to installation and/or disassembly!
Connect the supply voltage/frequency as stated on the product!
Initial operation
Manual switching
Program
- Schrack Technik GmbH Seybelgasse 13 AT-1230 Wien
- Internet : www.schrack.at
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>