NICOR TACS214U Select Architectural LED Troffer Instructions

June 16, 2024
NICOR

NICOR-LOGO

NICOR TACS214U Select Architectural LED Troffer

NICOR-TACS214U-Select-Architectural-LED-Troffer-
PRODUCT

Product Description

  • The TAC Select Architectural LED Troffer is an economical lighting solution for commercial, educational, medical, and retail applications where general-purpose ambient lighting is required.
  • With its contemporary center lens design, TACS provides a soft natural glow and even illumination that minimizes glare.
  • The CCT Selectable design allows for easy adjustment to 3500K, 4000K, or 5000K and selectable wattage allows the ability to tailor the brightness to the space.
  • Available in 1×4, 2×2, or 2×4 configurations, the TACS is an easy-to-install upgrade from linear fluorescent lighting to a long-lasting, energy-efficient LED solution.

Construction

  • Durable steel construction with matte white powder coat finish
  • High-efficiency, maintenance-free LED chamber
  • Smooth-formed sides for safe handling

Optical System

  • Precision-engineered PMMA diffuser
  • No visible diodes, hot spots, or shadows provide high uniformity, and reduced glare
  • 80CRI for good color definition in public spaces

Electrical

  • Input voltage of 120-277VAC
  • CCT and Output selector switches are accessible on the junction box
  • Full-range dimming via 1-10VDC controls
  • Power factor > 0.9
  • THD < 20%
  • Operating temperature range: -4°F to 104°F (-20° to 40°C)

Controls

  • The NLC (Network Lighting Controls) option is available
  • Bluetooth Low Energy (BLE) mesh network providing Luminaire Level Lighting Control
  • Luminaire integrated BLE PIR/Daylight sensor (N1) available
  • Configurable with the NICOR NLC app available on iOS and Android devices
  • Provides full dimming control with occupancy and daylight harvesting functions

Mounting and installation

  • Quick and easy single-person installation
  • Features an integral driver for easy installation
  • Attached grid clip with a wire-tie hole provided for seismic wire
  • Certified for direct contact with insulation
  • Surface mount installation with an optional adapter
  • Drywall installation with an optional adaptor
  • Emergency battery backup is available
  • For installations where a power surge may be possible, NICOR recommends installing additional surge protection at the fixture or electrical distribution panel

Listings

  • cULus1598 Listed for damp locations
  • Certified for direct contact with insulation (IC)
  • DLC 5.1 Premium listed
  • RoHS Compliant
  • Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions
  • TM-21 Reported L70(9k) life >54,000 hours
  • LM-79, and LM-80 testing performed under IESNA standards

Ordering

Ordering Information       Example: TACS224U
Series CCT Version Size Voltage

Emergency
TAC| S (Select: 35K, 4K, 5K)| 2| 14 (1’ x 4’)| U (120-277V)| Blank (none)| < BLANK>
 |  |  | 22 (2’ x 2’)|  | NI (NLC Controls)| E1 (EMB045)
 |  |  | 24 (2’ x 4’)|  |  | E2 (EMB080)

Specifications and dimensions are subject to change without notice.

Accessories

  • Surface Mount Kit – 1×4 SK14M10WH
  • Surface Mount Kit for use with E1/E2 – 1×4 SK14M10WH
  • Flange Kit – 1×4 TPE10FK14
  • Surface Mount Kit – 2×2 SK22M10WH
  • Surface Mount Kit for use with E1/E2 – 2×2 SK22M10WH
  • Flange Kit – 2×2 TPE10FK22
  • Surface Mount Kit – 2×4 SK24M10WH
  • Surface Mount Kit for use with E1/E2 – 2×4 SK24M10WH
  • Flange Kit – 2×4 TPE10FK24

Recommended Dimmers

  • Lutron NTSTV
  • Leviton IP710
  • Cooper SF10P
  • Legrand RH4FBL3PW
  • Not a complete list. Check compatibility before installation.

NLC Controls

Performance Data

Performance Data

Model| OutputSetting| Nominal CCT| Lumens| Watts| Efficiency
 |  | 3500| 2741| 20.5| 133.7
Standard| 4000| 2901| 20.1| 144.3
 | 5000| 2767| 20.2| 137.0
 |  | 3500| 3350| 25.7| 130.4
TACS214U| Medium| 4000| 3546| 25.0| 141.8
 |  | 5000| 3377| 25.2| 134.0
 |  | 3500| 3931| 30.7| 128.0
High| 4000| 4122| 30.0| 137.4
 | 5000| 3982| 30.3| 131.4
 |  | 3500| 2729| 20.4| 133.8
Standard| 4000| 2905| 20.0| 145.3
 | 5000| 2755| 20.1| 137.1
 |  | 3500| 3343| 25.8| 129.6
TACS222U| Medium| 4000| 3536| 25.1| 140.9
 |  | 5000| 3369| 25.3| 133.2
 |  | 3500| 3904| 30.6| 127.6
High| 4000| 4118| 29.9| 137.7
 | 5000| 3955| 30.2| 131.0
Performance Data

Model| OutputSetting| Nominal CCT| Lumens| Watts| Efficiency
 |  | 3500| 4399| 34.6| 127.1
Standard| 4000| 4620| 33.9| 136.3
 | 5000| 4426| 34.1| 129.8
 |  | 3500| 4807| 37.9| 126.8
TACS224U| Medium| 4000| 5047| 36.9| 136.8
 |  | 5000| 4836| 37.2| 130.0
 |  | 3500| 5478| 43.4| 126.2
High| 4000| 5752| 42.5| 135.3
 | 5000| 5511| 42.9| 128.5

Photometric Data

TACS14 3500K, 30W

  • Input Voltage (VAC) 120-277
  • System Level Power (W) 30.7
  • Delivered Lumens (Lm) 3931
  • System Efficacy (Lm/W) 128.0
  • Correlated Color Temp (K) 3500K
  • Color Rendering Index (CRI) 80
  • Beam Angle 114.9°
  • Spacing Criteria 1.20NICOR-TACS214U-Select-Architectural-LED-Troffer-FIG-2
  • Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.
  • NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com April 4, 2023, 8:43 AM TACSv2

TACS22 3500K, 30W

  • Input Voltage (VAC) 120-277
  • System Level Power (W) 30.6
  • Delivered Lumens (Lm) 3904
  • System Efficacy (Lm/W) 127.6
  • Correlated Color Temp (K) 3500K
  • Color Rendering Index (CRI) 80
  • Beam Angle 94°
  • Spacing Criteria 1.24 NICOR-TACS214U-Select-Architectural-LED-Troffer-FIG-4

TACS24 3500K, 43W

  • Input Voltage (VAC) 120-277
  • System Level Power (W) 43.4
  • Delivered Lumens (Lm) 5478
  • System Efficacy (Lm/W) 126.2
  • Correlated Color Temp (K) 3500K
  • Color Rendering Index (CRI) 80
  • Beam Angle 117°
  • Spacing Criteria 1.22 NICOR-TACS214U-Select-Architectural-LED-Troffer-FIG-6
  • Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture.
  • Results may vary in the field.

Dimensions

NICOR-TACS214U-Select-Architectural-LED-Troffer-FIG-7

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com April 4, 2023 8:43 AM TACSv2

  • Project——————————–
  • Catalog—————————-
  • Type—————————–
  • Date——————————-

Documents / Resources

| NICOR TACS214U Select Architectural LED Troffer [pdf] Instructions
TACS214U, TACS222U, TACS224U, TACS214U Select Architectural LED Troffer, TACS214U, Select Architectural LED Troffer, Architectural LED Troffer, LED Troffer, Troffer
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals