MINOSTON MT10N 4 Hour Countdown Timer Switch User Manual
- June 16, 2024
- Minoston
Table of Contents
MT10N 4 Hour Countdown Timer Switch
Countdown Timer Switch
Model — MT10N(NHT06)
Specifications:
Power: 120VAC, 60Hz
Incandescent Load: 960W
Motor Load 1/2HP
Resistive Load 1800W
Temperature Range: 32° F~104° F
Time Delay: 5 Min / 10 Min / 30 Min / 60 Min / 2 Hour / 4 Hour
HOW TO INSTALL THE WIRES
- Unscrew: carefully turn the screw counterclockwise to leave enough space for the wire to be inserted. Do not unscrew the screws completely.
- Press down: Once loosened, use your finger so it catches the thread,
- Insert the wire: make sure the wire is completely straight, then insert it into the terminal while holding down the screw. Do not wrap the wire around the screw!
- Tighten: Turn the screw clockwise to tighten the wire. Make sure the wires are locked!
Note: There are 2 holes for each terminal can be used in the connection. You can use a jump wire or the second hole at the terminal to connect.
Single – pole wiring
-
Tool: Please prepare a flat head screwdriver.
-
Turn power OFF at circuit breaker or fuse box.
-
Remove wallplate.
-
Remove the switch mounting screws.
-
Disconnect the wires and label them after remove the old switch, (Please use our sticker)
-
Carefully remove the switch from the switch box. (DO NOT disconnect the wires.)
-
There are up to five screw terminals on the smart switch, these are marked (Please check
) -
Fix the wallplate with screws after wiring succeed, (Please use our screws.)
-
The Ground was excluded from the diagram to simplify the illustration. Please Make sure all ground wires are connected to all switches res- pectively.
FCC warning:
This device complies with Part 15 of the FCC Rules, Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference,
(2) This device must accept any interference received, including interference
that may cause undesired operation. changes or modifications not expressly
approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be cotocated or operating
in conjunction with any other antenna or transmitter. This equipment should be
installed and operated with minimum distance 20cm between the radiator& your
body.
CAUTION = PLEASE READ!
This device is intended for instalation in accordance with the National
Electric Code and local regulations in the United States, or the Canadian
Electrical Code and local regulations in
Canada, If you are unsure or uncomfortable about performing this installation
consult a qualified electrician.
MEDICAL EQUIPMENT
Please DO NOT use this plug to control Medical or Life Support equipment. This
device should never be used to control the On/Off status of Medical and/or
Life Support equipment,
OTHER WARNINGS
Risk of Fire / Risk of Electrical Shock / Risk of Burns
IMPORTANT SAFETY INSTRUCTIONS
- READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
- Read and follow all instructions that are on the product or provided with the product.
- do not use an extension cord.
- Reference the National Electrical Code, NFPA 70, specifically for the installation of wiring andclearances from power and lighting conductors,
- Installation work and electrical wiring must be done by qualified person(s) in accordance with allapplicable codes and standards, including fire-rated construction.
- do not install or use within 10 feet of a pool
8 WARNING:
Risk of Electric Shock,
When used outdoors, install only to a covered Class A GFCI protected
receptacle that is weatherproof with the power unit connected to the
receptacle. If one is not provided, contact a qualified electrician for proper
installation. Ensure that the power unit andcord do not interfere with
completely closing the receptacle cover.
9. WARNING:
Risk of Electric Shock, Mount the unit at a height greater than 1 foot from
the ground surface
10.WARNING:
Risk of Electric fire. install only to a receptacle protected by 20A branch
circuit over current protection.
SAVE THESE INSTRUCTIONS – this manual contains important safety and
operating instructions.
If you have any questions, please contact us at
Scan QR code or visithttps://minoston.com/
ask@minoston.com and
www.minoston.com