Newentor MT4-193 Dual Layer Memory Foam Mattress Topper Owner’s Manual

June 16, 2024
Newentor

Newentor MT4-193 Dual Layer Memory Foam Mattress Topper

Newentor-MT4-193-Dual-Layer-Memory-Foam-Mattress-Topper-
product

Product Information

Specifications

  • Product Name: Newentor Mattress Topper
  • Product Specification: MT1
  • Manufacturer: Newentor

Test Results

The product has undergone testing by the low hazard requirements of BS 7177:2008+A1:2011. The test results indicate that the product meets the specified performance requirements for resistance to ignition.

Test Result Summary

Test Requested Result Comments

Resistance to ignition of mattresses, mattress pads, divans and
bed bases (BS 7177:2008+A1:2011)| PASS| Clause 5 and 6 weren’t checked.

Test Conducted

The tests were conducted by the low hazard requirements of BS 7177:2008+A1:2011. The test methods used were based on BS EN 597-1 & 2:1995 and BS 5852- Part 2:1982.

Sample Description
The sample used for testing was a mattress.

Precondition and Test Condition

Temperature Precondition Test Condition
25.0 Duration 24h

Test Results

Clause Principle / Requirement Result
4.1.1 The composite shall meet the levels of ignition resistance low

hazard composite test. Both surfaces of the mattress or mattress
pad shall be tested unless they are identical.| a) PASS
b) PASS (See Annex I)
4.1.2| All filling materials, including those used in mattress pads,
shall pass the relevant test: Polyurethane foam in block or cushion
form shall pass the relevant test contained in Annex A.| PASS (See Annex II)
4.2| All outer covers and inner covers are intended for high or very
high-hazard categories that have been chemically treated to reduce
their ignitability shall be subjected to the water soaking and
drying procedure specified in BS 5852:2006, Annex E prior to being
conditioned.| N/A

Sampling and Frequency of Testing

A sample of each mattress, mattress pad, divan, or bed base specification (ignoring differing spring types) shall be tested at the frequency specified in Table 3. Retesting shall be carried outwhere there is any major basic alteration to a specification.

Labeling and Identification

Each mattress, upholstered mattress pad, divan, or bed base shall carry a label and identification as specified in the relevant standards.

Product Usage Instructions

Step 1: Preparing the Mattress Topper

  1. Unpack the mattress topper from its packaging.
  2. Allow the mattress topper to fully expand for at least 24 hours.

Step 2: Placing the Mattress Topper on the Bed

  1. Remove any existing bedding from the bed.
  2. Place the mattress topper on top of the mattress, ensuring it is centered and aligned.

Step 3: Securing the Mattress Topper

  1. Secure the mattress topper to the mattress using the provided elastic straps or corner fasteners.
  2. Adjust the straps or fasteners to ensure a snug fit.

Step 4: Adding Bedding

  1. Add your preferred bedding, such as sheets, blankets, and pillows, on top of the mattress topper.
  2. Make sure the bedding is evenly spread and tucked in securely.

Step 5: Maintenance and Care

To keep your mattress topper clean and in good condition, follow these guidelines:

  • Regularly remove and wash the mattress topper cover according to the care instructions provided.
  • Vacuum or spot clean the mattress topper as needed to remove any dirt or stains.
  • Avoid exposing the mattress topper to direct sunlight for extended periods.

FAQ

  • Q: How long does it take for the mattress topper to fully expand?
    A: We recommend allowing the mattress topper to fully expand for at least 24 hours after unpacking.

  • Q: Can I wash the mattress topper cover?
    A: Yes, you can remove and wash the mattress topper cover according to the care instructions provided.

  • Q: How should I secure the mattress topper to the mattress?
    A: The mattress topper can be secured to the mattress using the provided elastic straps or corner fasteners. Adjust them to ensure a snug fit.

Test Result Summary

No. Test(s) Requested Result(s) Comments

1

| Low hazard in BS 7177:2008+A1:2011 Specification for resistance to ignition of mattresses, mattress pads, divans and bed bases| ****

PASS

| Clause 5 and

6 weren’t checked.

For further details, please refer to the following page(s)

Test Conducted:
These tests are conducted in low hazard of BS 7177:2008+A1:2011 according to the application, the test methods are based on BS EN 597-1 & 2:1995 and BS 5852-part 2:1982.

  1. Sample Description: Mattress
  2. Precondition and Test Condition
     | Temperature| Relative Humidity| Duration
    ---|---|---|---
    Precondition| (23±2)℃| (50±5)%| 24h
    Test Condition| 25.0℃| 52%| —
  3. Test Results
    Clause| Principle / Requirement| Result
    ---|---|---










4

| Performance requirements for resistance to ignition
4.1 Ignitability    Low hazard
4.1.1| The composite shall meet the levels of ignition resistance low hazard composite test. Both surfaces of the mattress or mattress pad shall be tested, unless they are identical.

a)      Smouldering cigarette as specified in BS EN 597-1:1995.

b)      Match flame equivalent as specified in BS EN 597-2:1995.

| a)    PASS

b)    PASS (See Annex I)

4.1.2| All filling materials, including those used in mattress pads, shall pass the relevant test:

Polyurethane foam in block or cushion form shall pass the relevant

test contained in the Annex A.

| ****

PASS(See

Annex II)

4.2| Durability of treatment

All outer covers and inner covers intended for high or very high hazard categories that have been chemically treated to reduce their ignitability shall be subjected to the water soaking and drying procedure specified in BS 5852:2006, Annex E prior to being conditioned.

| ****



N/A

Clause Principle / Requirement Result
5 Sampling and frequency of testing

A sample of each mattress, mattress pad, divan or bed base specification (ignoring differing spring types) shall be tested at the frequency specified in Table 3.

Retesting shall be carried out where there is any major basic alteration to a

specification.

| ****



N/P

6| Labeling And Identification

Each mattress, upholstered mattress pad, divan or bed base shall carry a permanently attached and clearly readable label (see Figures 1 to 4). The size of the graphic part of the label shall be not less than 50 mm × 50 mm. The base color of the label shall be white with a blue border. The word “RESISTANT” shall appear on the border and shall be white and of a minimum height 5 mm. A smoldering cigarette symbol, flame symbol, and the ignition source number(s) shall appear in the central white area and shall be black. Information defining additional tests shall be included on the label for very high-hazard mattresses and upholstered mattress pads.

The following wording shall appear on the label:

“Conforms to BS 7177:2008 for domestic use (low hazard)” shall appear on the label.

| ****








N/P

Remark : N/A=Not Applicable, N/C=Not Conduct as per client’s request, N/P=Not Provided.

Test Results:

The following test results relate only to the ignitability of the sample or combination of materials under the particular condition of test. They are not intended as a means of assessing the full potential fire hazard of the materials or products in use.
(A) BS EN 597-1:1995 Furniture – Assessment of the ignitability of mattresses and upholstered bed bases Part 1: Ignition source smoldering cigarette

Test  Criteria Results
1 st 2 nd

(A) Progressive Smouldering Ignition
①Any test assembly that displays escalating smouldering combustion behaviour so that it is unsafe to continue the test and active extinction is necessary;|


NO

| ****

NO

② Any test assembly that smoulders until it is largely consumed within the test duration;| ****

NO

| ****

NO

③ Any test assembly that smoulders to its full thickness, within the duration of the test;| ****

NO

| ****

NO

④ Any test assembly that smoulders for more than one hour;| NO| NO
⑤On final examination, show evidence of charring more than 50mm in any horizontal direction from the nearest point of the original position of the source.| ****

NO

| ****

NO

(B)Flaming ignition
A flaming ignition is considered to be the occurrence of any flames initiated by a progressive smouldering source| ****

NO

| ****

NO

Test  Criteria Results
1 st 2 nd

(C) Final examination
Immediately after completion of the test programme on the assembly, dismantle it and examine it internally for progressive smouldering ignition, if this is found,

extinguish the test assembly, and record an ignition and complete the test report.

| ****

No Ignition

Test details:

Test

|

Ignition Position

| After Placement of the Cigarette| Extent of Damage(mm)|

Comments and Observations

---|---|---|---|---
Progressive Smouldering

Time

| Flame Ceased

Time

| Smoking Ceased Time|

Width

|

Length

|

Corner

1st

| Flat Portion| 0s| 0s| 18min32s| 4| 6| 3| #2
Tape Edge| 0s| 0s| 18min21s| 5| 5| 3| #2

2nd

| Flat Portion| 0s| 0s| 19min04s| 5| 6| 3| #2
Tape Edge| 0s| 0s| 18min58s| 5| 6| 3| #2

Sub – Conclusion: PASS

BS EN 597-2:1995 Furniture – Assessment of the ignitability of mattresses and upholstered bed bases Part 2, Ignition source: match flame equivalent (15+1s).

Test Criteria Test Result
1 st 2 nd

(A) Progressive Smouldering Ignition
①Any test assembly that displays escalating smouldering combustion behaviour so that it is unsafe to continue the test and active extinction is necessary;|


NO

| ****

NO

② Any test assembly that smoulders until it is largely consumed within the test duration;| ****

NO

| ****

NO

③ Any test assembly that smoulders to its full thickness, within the duration of the test;| ****

NO

| ****

NO

④ Any test assembly that smoulders for more than one hour;| NO| NO
⑤On final examination, show evidence of charring more than 50mm in any horizontal direction from the nearest point of the original position of the source.| ****

NO

| ****

NO

(B)Flaming ignition
① Any test specimen that escalating combustion behaviour is observed so it is unsafe to continue the test| ****

NO

| ****

NO

② Any test specimen that burns until it is essentially consumed within the test duration.| ****

NO

| ****

NO

③ Any test specimen on which any flame front reaches its extremities or passes through its full thickness within the duration of the test.| ****

NO

| ****

NO

④Any test specimen that flaming continues to more than 120s after removal of the burner.| ****

NO

| ****

NO

Test Criteria Test Result
1 st 2 nd

(C)Final examination

Immediately after completion of the test programme on the assembly, dismantle it and examine it internally for progressive smouldering ignition, if this is found, extinguish the test assembly, and record an ignition and complete the test report.

| ****


No Ignition

Test details:

Test

|

Ignition

| Time to Extinction after

Removal of the Burner(second)

| Extent of Damage(mm)| Comments and Observations
---|---|---|---|---
Position| Flame Ceased

time

| Smoking

Ceased Time

| Width| Length| Depth

1st

| Flat Portion| 0| 5| 16| 18| 4| #3
Tape Edge| 0| 5| 14| 20| 3| #3

2nd

| Flat Portion| 0| 5| 15| 18| 4| #3
Tape Edge| 0| 6| 16| 21| 3| #3

Sub – Conclusion: PASS

Filling material test as per BS 5852 Part 2: 1982

This test, specified in Annex A of BS 7177:2008+A1:2011, is based on BS 5852 part 2:1982 using ignition source 5.
To assess the ignitability of polyurethane foam in slab or cushion form used in upholstered components when subjected to ignition 5.

Sample Details:

Filling No Materials Density
1 Foam Approximately

38.7 kg/m3

2| Foam| Approximately

33.7 kg/m3

Specified Thickness of

Specimen

| (75±2) mm| Actual Thickness of

Specimen

| Filling 1&2: 75 mm
Precondition| Indoor Ambient Condition| 72 h
---|---|---
Conditioning of Test Specimen and Ignition

Source(s)

| ****

Temperature:(23±2)℃;Relative Humidity: (50±5)% Duration:24 h;

Testing Enclosure (fume

cupboard / room)

| 24.6 ℃| RH 56 %| —

Test Results:
Filling 1:


Test Criteria

| Results
---|---
1 st test| 2 nd test
(A) Progressive smouldering (Clause 4.1 of BS 5852 part 2:1982)
① Whether progressive smouldering is observed when beyond 60 minutes

after ignition of the crib

| NO| NO


Test Criteria

| Results
---|---
1 st test| 2 nd test
② Whether escalating combustion behaviour is observed so that it is unsafe to continue the test| ****

NO

| ****

NO

③ Whether any composite smoulders until it is essentially consumed within the test duration .| ****

NO

| ****

NO

④ Whether any composite that smoulders to the extremities the specimen viz. upper or lower margins , either side or to its full thickness within the duration of the test| ****

NO

| ****

NO

⑤ Whether any composite on final examination shows evidence of charring more than 100mm in any direction| ****

NO

| ****

NO

(B) Flaming (Clause 4.2 of BS 5852 part 2:1982)
① Whether any composite that continues to flame for more than 10 minutes after the ignition of the crib| ****

NO

| ****

NO

② Whether escalating combustion behaviour is observed so that it is unsafe to continue the test| ****

NO

| ****

NO

③ Whether any composite is essentially consumed within the test duration| NO| NO
④ Whether any composite display that on which flame front reaches the lower margin, either side or passes through the full thickness of the specimen within the duration of the test| ****

NO

| ****

NO


Test Criteria

| Results
---|---
1 st test| 2 nd test
(C) Mass Loss (Clause 5 in Schedule 1 Part1 of UK Regulations)
If failure against the criteria of clause 4 of BS 5852 : part 2 has occurred but only by way of damage exceeding the limits defined in A ④, ⑤ and B ④ above and provided that the resultant mass loss is less than 60g the foam passes the ignitability test.| ****


31 g

| ****


33 g

Test Details:

Test No. 1st 2nd


Duration of

| Ignition source (min, sec)| 02min42s| 02min44s
Flames (min, sec)| 03min18s| 03min40s
Smoke (min, sec)| 08min54s| 09min28s
Extent of damage of horizontal component| Foam – Width (mm)| 92| 96
Foam – Length (mm)| 150| 154
Foam – Depth (mm)| 60| 61
Extent of damage of vertical component| Foam – Length (mm)| 179| 182
Foam – Depth (mm)| 48| 50
The initial mass of the sample composite (g)| 7810| 7815
The final mass of sample composite(g)| 7779| 7782
The final mass loss of the composite(g)| 31| 33
Rating, comments & observations| #7| #7

Sub – Conclusion: PASS

Filling 2:


Test Criteria

| Results
---|---
1 st test| 2 nd test
(A) Progressive smouldering (Clause 4.1 of BS 5852 part 2:1982)
① Whether progressive smouldering is observed when beyond 60 minutes

after ignition of the crib

| NO| NO
② Whether escalating combustion behaviour is observed so that it is unsafe to continue the test| ****

NO

| ****

NO

③ Whether any composite smoulders until it is essentially consumed within the test duration .| ****

NO

| ****

NO

④ Whether any composite that smoulders to the extremities the specimen viz. upper or lower margins , either side or to its full thickness within the duration of the test| ****

NO

| ****

NO

⑤ Whether any composite on final examination shows evidence of charring more than 100mm in any direction| ****

NO

| ****

NO

(B) Flaming (Clause 4.2 of BS 5852 part 2:1982)
① Whether any composite that continues to flame for more than 10 minutes after the ignition of the crib| ****

NO

| ****

NO

② Whether escalating combustion behaviour is observed so that it is unsafe to continue the test| ****

NO

| ****

NO

③ Whether any composite is essentially consumed within the test duration| NO| NO
④ Whether any composite display that on which flame front reaches the lower margin, either side or passes through the full thickness of the specimen within the duration of the test| ****

NO

| ****

NO


Test Criteria

| Results
---|---
1 st test| 2 nd test
(C) Mass Loss (Clause 5 in Schedule 1 Part1 of UK Regulations)
If failure against the criteria of clause 4 of BS 5852 : part 2 has occurred but only by way of damage exceeding the limits defined in A ④, ⑤ and B ④ above and provided that the resultant mass loss is less than 60g the foam passes the ignitability test.| ****


32 g

| ****


35 g

Test Details:

Test No. 1st 2nd


Duration of

| Ignition source (min, sec)| 02min44s| 02min45s
Flames (min, sec)| 04min25s| 04min41s
Smoke (min, sec)| 09min30s| 09min55s
Extent of damage of horizontal component| Foam – Width (mm)| 101| 104
Foam – Length (mm)| 152| 159
Foam – Depth (mm)| 62| 64
Extent of damage of vertical component| Foam – Length (mm)| 155| 158
Foam – Depth (mm)| 54| 57
The initial mass of the sample composite (g)| 7699| 7691
The final mass of sample composite(g)| 7667| 7656
The final mass loss of the composite(g)| 32| 35
Rating, comments & observations| #7| #7

Sub – Conclusion: PASS

Remark: N/A— Not Applicable, N/C -Not Conduct

  1. Cigarette fails to smoulder its complete length;
  2. Cigarette passes to smoulder its complete length, but the sample was not ignition;
  3. The sample was not ignited after removal of the burner;
  4. Flaming but self-extinguishment;
  5. Extinguished by operator, escalating flaming combustion;
  6. The first test failed, so retest was not conducted.
  7. Pass, flaming but self-extinguishment, the resultant mass loss is less than 60g;
  8. Fail, flaming but self-extinguishment, the resultant mass loss is more than 60g;
  • Filling 1 of this test report is extracted from the test report number SDFS2312007898FF. The Sample Receiving Date was Dec. 11, 2023, The Performing Date was Dec. 11, 2023 to Dec. 15, 2023.
  • Filling 2 of this test report is extracted from the test report number SDFS2312007899FF. The Sample Receiving Date was Dec. 11, 2023, The Performing Date was Dec. 11, 2023 to Dec. 15, 2023.

Note : This document cannot be reproduced except full, without prior written approval of the Company.

Photo Appendix

Newentor-MT4-193-Dual-Layer-Memory-Foam-Mattress-Topper-
fig- \(2\)

Appendix information: The above test was carried out by Shunde Branch SGS-CSTC Co., Ltd. laboratory. In the territory of the People’s Republic of China, the test report with CMA logo expresses that the test items are within the scope of China Metrology Accreditation(CMA); without CMA logo expresses that part/all of the test items are not within the scope of China Metrology Accreditation(CMA), and just for client internal reference.
End of report

Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at https://www.sgs.com/en/Terms-and-Conditions, Attention is drawn to the limitation of liability, indemnification, and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the samples) tested and such sample(s) are retained for 30 days only.
Attention : To check the authenticity of the testing /inspection report & certificate, please contact us at telephone: (86-755) 8307 1443, or email: [email protected]

TEST REPORT

  •  No. : GZIN2312004129PL01_EN
  • Date : 2023-12-15
  • Page: 15 of 15

CUSTOMER NAME : SHENZHENBAOANQUYIDEDANGKANGDIANZISHANGWUSHANGHANG ADDRESS: 26DONG BDONG 429, XIXIANGJIEDAO YANTIANSHEQU YINTIANGONGYEQU, BAOAN, SHENZHEN, GUANGDONG,518100, CHINA
Sample Name : Newentor Mattress Topper
Product Specification : MT1
Manufacturer : Newentor

Above information and sample(s) was/were submitted and confirmed by the client. SGS, however, assumes no responsibility to verify the accuracy, adequacy and completeness of the sample information provided by client.

Date of Receipt : 2023-12-06
Testing Period : 2023-12-06 ~ 2023-12-15
Test result( s) : For further details, please refer to the following page(s) (Unless otherwise stated the results shown in this test report refer only to the sample(s) tested)

Signed for SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.
Quincey Lee