IDAHO JONES IJ0046 Twain Portable Breast Pump Owner’s Manual

June 16, 2024
IDAHO JONES

IDAHO JONES IJ0046 Twain Portable Breast Pump

Product Information

Specifications

  • Product Name: TWAIN Portable Breast Pump
  • Technology : Soft Silicone 360 Fit
  • Flange Size : 2x25mm
  • Attachments : 19mm, 21mm, and 29mm (sold separately)

User Guide
The Idaho Jones Twain Portable Breast Pump with Silicone 360 Fit Flange Technology is a suction device intended to express and collect milk from a lactating person’s breasts. It’s one of the few dual breast pumps with completely independent suction settings for the left and right breast! You can completely customize your pumping experience to your unique preferences and achieve maximum comfort and breastmilk output. This pump is intended for a single user.

Important Safety Information
Read this user guide carefully before using your breast pump. Save the user guide for future reference. Failure to follow the instructions and safety information included in this guide can lead to danger from the device.

What’s in the Box

  1. Shield cap x2
  2. 25mm 360 Fit Flange with Integrated duckbill valve x2
  3. Breast shield x2
  4. Silicon diaphragm x2
  5. Diaphragm cap x2
  6. AC adapter x1
  7. Tubing connector x2
  8. Tubing x2
  9. Pump unit x1
  10. Bottle stand x2
  11. Wide neck bottle (4oz) x2
  12. Narrow neck bottle connector x2
  13. Bottle cap x2
  14. Nipple x2
  15. Nipple collar x2
  16. Nipple cap x2

Cleaning

IMPORTANT NOTE : Make sure that all parts are totally dry prior to use. Wet or damp parts can cause poor suction.

How to Assemble

  1. Assemble the breast shield kit:
    • Insert the soft silicone flange into the breast shield.
    • Ensure the valve is securely attached to the breast shield at the top.
  2. Assembling the diaphragm:
    • Press the silicone diaphragm down with your fingers so it’s flush with the top of the breast shield.
    • Place the diaphragm cap on with the hole for the tubing insert positioned slightly to the right.
    • Twist the cap to the left until it’s tightly in place.
  3. Assembling the bottle and base:
    • Twist the bottle to secure the breast shield kit onto the bottle.
    • Place the bottle on the bottle stand, if using.
  4. Connecting to the pump:
    • Connect one end of the tubing to the diaphragm cap and the other end to the pump unit.
    • Please make sure that both ends are attached securely. Failure to do so might affect the suction of the pump.

Pump Motor Instructions

Controls :

  1. Left Side Pumping : Increase Suction Level Button
  2. Left Side Pumping : Reduce Suction Level Button

Frequently Asked Questions (FAQ)

  • Q: Can I use the breast pump if it’s causing discomfort?
  • A: If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the breast and breast shield with your finger, and remove the breast shield from your breast. If irritation or discomfort occurs, discontinue use and consult your lactation consultant.

Idaho Jones Twain Portable Pump

INDICATIONS FOR USE
The Idaho Jones Twain Portable Breast Pump with Silicone 360 Fit Flange Technology is a suction device intended to express and collect milk from a lactating person’s breasts. It’s one of the few dual breast pumps with completely independent suction settings for the left and right breast! You can completely customize your pumping experience to your unique preferences and achieve maximum comfort and breastmilk output.

This pump is intended for a single user.

Important Safety Information
Read this user guide carefully before using your breast pump. Save the user guide for future reference. Failure to follow the instructions and safety information included in this guide can lead to danger from the device.

  • When using any electrical products, basic safety precautions should always be followed.
  • Read all instructions before using.
  • This product is intended for personal use and for one user only. Use by more than one person may present a health risk.
  • Do not use the pump motor while bathing, showering or swimming
  • Do not reach for the pump motor if it has fallen into water. Immediately unplug from electrical outlet.
  • Do not place or drop the pump motor into water or other liquid.
  • Do not spray or pour liquid directly on to the pump motor.
  • Do not place or store the pump motor where it can fall or be pulled into a sink or tub.
  • Never use while sleeping or when drowsy.
  • Do not drop or insert any object into any opening of the pump unit.
  • Do not use this product if it is broken or any parts are missing.
  • Close supervision is necessary when this product is used near children.
  • Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, dropped into water, or if any parts are broken or missing.
  • Do not place the pump near any appliances generating a strong magnetic field.

Make sure all parts are assembled correctly before pumping.

  • This product should never be left unattended when plugged in.
  • Keep the cord away from heated surfaces.
  • Always unplug electrical product immediately after use.
  • Use this product only for its intended use as described in this manual.
  • Do not allow small children or pets to play with the pump unit, AC adapter, etc.
  • Do not operate where aerosol spray products are being used or where oxygen is being administered.

Caution:
If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the breast and breast shield with your finger and remove the breast shield from your breast. If irritation or discomfort occurs, discontinue use and consult your lactation consultant.

Cleaning

BEFORE FIRST USE

  • Disassemble all parts and put the pump motor aside.
  • Wash all silicone and plastic parts in warm soapy water.
  • Rinse well with clean water.
  • Submerge all parts in a pot of water and boil for no longer than 3 minutes.
  • Use a large pot to prevent parts from touching sides or the bottom of pot.
  • Shake off excess water and air-dry on a dedicated rack or clean cloth.
    • DO NOT let the pump motor come in contact with water. If you want to clean them, you can wipe them with a clean, damp cloth.

AFTER EACH USE

  • Put the pump motor aside.
  • Disassemble all other parts (collection cup, silicone breast shield, insert, valve, valve base and membrane).
  • Rinse with cold clean water soon after use.
  • Wash in warm soapy water.
    • Valves section of the flanges can be cleaned by gently rubbing between fingers (do not use brush).
  • Rinse well.
  • Shake off excess water and air-dry on a dedicated rack or clean cloth.
    • Do not wash parts in the dishwasher.

HOW TO SANITIZE

  • Follow the cleaning instructions for “after each use” above.
  • Use UV or cold water sterilization.
    • DO NOT steam sterilize or boil after the first time.

IMPORTANT NOTE : Make sure that all parts are totally dry prior to use. Wet or damp parts can cause poor suction.

CLEANING THE TUBING

  • Since the Idaho Jones Twain Pump has a closed system, it is not necessary to clean the tubing.
  • If you see moisture in the tubes after pumping:
    • Remove the tubes from the breast shields
    • Turn on the pump for a few minutes until the moisture is gone.

How to Assemble

  1. Assemble the breast shield kit:
    Insert the soft silicone flange into the breast shield. Ensure the valve is securely attached to the breast shield at the top.

  2. Assembling the diaphragm:
    Press the silicone diaphragm down with your fingers so it’s flush with the top of the breast shield. Place the diaphragm cap on with the hole for the tubing insert positioned slightly to the right. Twist the cap to the left until it’s tightly in place.

  3. Assembling the bottle and base:
    Twist the bottle to secure the breast shield kit on to the bottle.

    • Place the bottle on the bottle stand, if using.
  4. Connecting to the pump: Connect one end of the tubing to the diaphragm cap and the other end to the pump unit. Please make sure that both ends are attached securely. Failure to do so might affect the suction of the pump.

Pump Motor Instructions

Controls

  1. Left Side Pumping: Increase Suction Level Button
  2. Left Side Pumping: Reduce Suction Level Button
  3. Left Side Pumping: On/Pause Button
  4. Alarm Clock Set Up Button
  5. Power Button
  6. Suction Mode Control : Stimulation, Expression or Combo
  7. Right Side Pumping : On/Pause Button
  8. Right Side Pumping : Reduce Suction Level Button
  9. Right Side Pumping : Increase Suction Level Button

Displays

  1. Suction Mode Display: Stimulation Mode Indicator
  2. Suction Mode Display: Expression Mode Indicator
  3. Left Side Pumping: Suction Level Display
  4. Child Lock Display: Press control buttons 1 and 2 at the same time to activate
  5. Battery Power Indicator
  6. Mute Display: Press control buttons 8 and 9 at the same time to activate
  7. Pump Timer Display
  8. Right Side Pumping: Suction Level Display
  9. Suction Mode Display: Combo Mode Indicator

How to Pump

Powering the Pump
Your Twain Pump can be operated either by using its in-built Lithium Ion battery or by using the provided AC adapter.

If using the pump with its battery power:

  • Make sure that the battery is fully charged before use.
  • The Battery Power Indicator “ ” will provide a real-time display of your battery status.
  • When the battery power runs out, the Indicator “ “ will flash and the pump will make a short beeping sound before turning off.

NOTE : When fully charged, the battery can last for around four 30-minute pumping session.

If using the pump with the AC adapter:

  • The in-built battery of the pump will be charging while you are still pumping.
  • The Battery Power Indicator “  ” will provide a real-time display of your battery charging status.

Getting Started

  1. Make sure your pump is fully charged if using the battery power or is plugged in to the power outlet if you are using the AC adapter.
  2. Attach 360 Fit Flange to your breast so that the nipple is centered and aligned straight toward the silicone cushion of the breast shield.
  3. Make sure your breast fills the breast shield so that a vacuum is formed and no air escapes.
  4. Long press the on/off button “ ” to switch on the pump.
  5. Your Twain Breast Pump will always start in the stimulation mode to help with let-down.

NOTE : When you turn the pump on for the very first time, it starts in stimulation phase, suction level 1. After the first use, it will start in the stimulation mode and suction level that was used last.

Side Selection

  • Left : To pump on the left, press the Left Side Pumping: On/Pause Button
  • Right : To pump on the right, press the Right Side Pumping: On/Pause Button
  • Dual : To pump on both sides, press both the Left and Right Side On/ Pause Buttons

Suction Mode Selection

  • Press the Suction Mode Control button “ ” to toggle between the three pumping modes: Stimulation, Expression or Combo.
  • Stimulation mode has rapid suction movements to elicit your milk ejection reflex (MER), otherwise known as a let-down. You can adjust the strength of the suction between 1-9 using the plus “ ” or minus “ ” buttons. Once you have had your let-down, press the Suction Mode Control button “ ” to switch to expression mode.
  • Expression mode has slower but deeper suction movements to extract as much milk from your breasts as possible. You can adjust the strength of the suction between 1-9 using the plus “ ” or minus “ ” buttons.
  • Combo mode toggles between stimulation (for 10 suction movements) and expression modes (for 5 suction movements) automatically. It’s great for eliciting further let-downs and for power pumping. You can adjust the strength of the suction between 1-9 using the plus “  ” or minus “ ” buttons.
  • You can press the Left or Right Pumping On/Pause Buttons (or both) to pause pumping and press again to resume.

NOTE : Your Twain Breast Pump is designed to turn off automatically after 30 minutes.

Additional Features

Child-Lock:

  • Activate by pressing the left side and buttons at the same time.
  • This feature locks the screen so if you (or your baby!) touches any of the buttons by accident, your pumping setting won’t change.

Mute:

  • Activate by pressing the right side and buttons at the same time.
  • This feature silences the buttons. When mute is activated, you can adjust your settings or press any of the buttons without any beeping sound.

Alarm:

  • You can set an alarm for your next pump directly on your pump so you don’t skip a pumping session.
  • The time range for the alarm is from 0 minutes to 23 hours.
  • When your pump is turned off, long press the button to activate the alarm clock will appear on an LED screen with flashing.
  • You can use the left side  and buttons to adjust the hour in 1-hour increments.
  • You can use the right side and buttons to adjust the minutes in 15-minute increments.
  • Once you reach your desired time interval, wait for 6 seconds and the alarm clock will be confirmed, starting its countdown. When the alarm clock function is activated, the countdown starts and “:“ will blink. When the time is reduced, the alarm will go off for 1 minute untill no longer flashes.
  • To cancel the alarm clock, press the button.

Finding the Correct Flange Fit

Your Twain Breast Pump comes with a 25mm 360 Fit Flange with an Integrated Duckbill Valve. Based on your nipple measurement, if you need to size up or down, you can separately purchase the Idaho Jones 360 Fit Flanges in the following sizes:

Troubleshooting

We summarize here the most common issues you can encounter while using your Twain Breast pump. If you are not able to solve the issue with the information below, please email us at hello@idaho-jones.com and we will do everything we can to help you.

Issue Solution
Low or no suction Ensuring tubing is firmly inserted into the

white cap.

Double check that the valve in the silicone cushion is flush with the breast shield and assess for any damage or wear, Replace silicone cushion if needed.

Make sure all parts are dry and securely attached.

Ensure the silicone diaphragm and white cap are firmly attached to the top of the breast shield. Place the white cap on with the hold for the tubing insert positioned slightly to the right. Twist the cap to the left until it’s tightly in place.

Ensure that no parts, especially the flange, silicone diaphragm and the tubes are not aged or worn out. If so, please replace them before trying again.

Condensation or milk in tubing| Ensure that the tubing, silicone diaphragm and white cap are dry before use.


If condensation occurs, ensure tubing is dry before next use. To do this, disconnect tubing from breast shields and turn the

pump back on to dry the tubing while you are storing away your breast milk.


Check the valves in the silicone cushion and the silicone diaphragm for damage. Replace if needed.


Do not sterilize tubing in the dishwasher, steam sterilizer or by boiling.

---|---
Pain in the breast area while pumping| Lower the suction level until you find a

comfortable suction intensity.


If pain persist even at a low intensity, please contact us or seek advice from a certified lactation consultant.

E1/E2 on the screen and alarm ring| This sound means that there is a short circuit in either E1 or E2. Send the pump back to the dealer for repair.
Condensation or milk in tubing| Ensure that the tubing, silicone diaphragm and white cap are dry before use.


If condensation occurs, ensure tubing is dry before next use. To do this, disconnect tubing from breast shields and turn the

pump back on to dry the tubing while you are storing away your breast milk.


Check the valves in the silicone cushion and the silicone diaphragm for damage. Replace if needed.


Do not sterilize tubing in the dishwasher, steam sterilizer or by boiling.

---|---
Pain in the breast area while pumping| Lower the suction level until you find a

comfortable suction intensity.


If pain persist even at a low intensity, please contact us or seek advice from a certified lactation consultant.

E1/E2 on the screen and alarm ring| This sound means that there is a short circuit in either E1 or E2. Send the pump back to the dealer for repair.

Technical Information


Power

| Input 100-240V~ S0/60Hz Output 5V ~ 2A
---|---


Battery

| Li-ion

3.7V ~ 3600mAh


Total Power

| ****

10W

Stimulation Mode Cycle Speed| ****

60 – 100 cycles/min


Stimulation Mode Vacuum

| 30 – 120 mmHg across 9 adjustable levels
Expression Mode Cycle Speed| ****

26 – 60 cycles/min


Expression Mode Vacuum

| 120 – 247 mmHg across 9 adjustable levels
Noise| ****

<60dB(A)


Operating Conditions

| Temperature: 5~40C, 40~140 F Relative humidity: 10-90%
Electronic Protection Equipment| ****

Class II

Warranty

There is a one-year warranty for the unit from the date of purchase. Proof of purchase in the form order number evidencing that the product is within the warranty period must be presented to obtain warranty. For warranty service, contact hello@idaho-jones.com. This is a single user product. Use by more than one person may present a health risk and void the warranty. The warranty is also void if you sell or otherwise transfer this product to another person or attempt to perform any maintenance or repair of this product.