My PowerClean®/MultiClean® Wet and Dry Vacuum is not blowing | Support
- June 7, 2024
- Bissell
Table of Contents
-
Remove hose
-
Turn machine on, check for suction at the opening on the front of the machine
-
Check for blowing at the opening on the tank lid on the back of the machine
-
Remove lid if no suction or blowing at opening by releasing latches on side of machine
-
Remove Fabric filter and clear of any debris
- Filter can be hand washed using cold water & mild dish soap
- Rinse well
- Allow to air dry completely before reinstalling (24 – 48 hours)
-
Empty tank
-
Clear debris from the suction inlet (both inside & out)
-
Remove the Filter Cage from the underside of the top cover
- Turn counter clockwise to unlock
-
Remove the Mesh Filter
- Mesh filter can be rinsed in cold water
- Allow to completely air dry before reinstalling (24 – 48 hours)
-
Make sure the float is positioned at the bottom of basket behind filter
- If not, tap basket – Float should move freely
-
Return Mesh filter to tank lid
-
Lock filter cage around mesh filter by twisting clockwise
-
Place Fabric filter into tank
- If Fabric filter is missing the Tank lid will not be secure & will result in reduced suction.
-
Reattach Tank lid, secure latches on both sides
-
Turn on & check again for suction at opening on front of machine
-
If still no suction, please visit a BISSELL Authorized Service Center or Contact Us
-
If opening does have suction/blowing, inspect the hose, wand, and attachment for clogs
-
Separate each piece
-
Remove curved piece at end of hose (push tabs to release)
-
Separate extension wands
-
Push broomstick through hose & wands to clear any debris or clogs
-
If hose, wand or any attachments are damaged they should be replaced
-