NICOR RSDS Surface Mount LED Downlight Owner’s Manual
- January 13, 2024
- NICOR
Table of Contents
- RSDS Surface Mount LED Downlight
- Product Information
- Specifications
- Performance Data
- Recommended Dimmers*
- Installation
- Light Temperature Selection
- Q: Can I use a dimmer switch with the RSDS Surface Mount LED
- Q: Can I install the RSDS downlight in a non-metallic junction
- Q: How do I change the light temperature of the RSDS
RSDS Surface Mount LED Downlight
Product Information
The RSDS Surface Mount LED Downlight is a thin installation
solution designed to fit into tight spaces. It features a twist
lock diffuser that can be easily removed for installation. The
direct box mount ensures that the downlight sits flush to the
ceiling, providing a clean and professional look. With CCT
Selectable technology, you can choose from 2700K, 3000K, 3500K,
4000K, and 5000K light temperatures to tailor the illumination to
your desired preference. This downlight is perfect for bringing
even illumination to any area of your home.
Specifications
- Series: RSDS
- Voltage: 120V
- CCT’s: 2700/3000/3500/4000/5000K
- Trim Color Options: White (WH), Black (BK), Nickel (NK),
Oil-rubbed Bronze (OB)
Performance Data
Model Number | Lumens | Watts | Lumens/Watt |
---|---|---|---|
RSD4S – 2700K | 613 | 10.89 | 56.3 |
RSD4S – 3000K | 655 | 10.90 | 60.1 |
RSD4S – 3500K | 643 | 10.53 | 61.1 |
RSD4S – 4000K | 676 | 10.89 | 62.1 |
RSD4S – 5000K | 633 | 10.66 | 59.3 |
RSD56S – 2700K | 921 | 15.36 | 60.0 |
RSD56S – 3000K | 999 | 15.41 | 64.8 |
RSD56S – 3500K | 1016 | 15.31 | 66.4 |
RSD56S – 4000K | 1025 | 15.41 | 66.5 |
RSD56S – 5000K | 999 | 15.40 | 64.9 |
RSD8S – 2700K | 1148 | 18.67 | 61.4 |
RSD8S – 3000K | 1264 | 18.73 | 67.5 |
RSD8S – 3500K | 1279 | 18.56 | 68.9 |
RSD8S – 4000K | 1298 | 18.72 | 69.3 |
RSD8S – 5000K | 1253 | 18.70 | 67.0 |
Recommended Dimmers*
- Lutron Diva DVCL-153P
- Lutron Maestro MACL-153M
- Eaton Cooper SLC03P
- Leviton IPL06
- Lutron DIVA DVELV-300P
*This is not a complete list. Please check compatibility before
installation.
Product Usage Instructions
Installation
-
Turn off the power supply to the installation area.
-
Remove the twist lock diffuser by twisting it
counterclockwise. -
Mount the direct box to the ceiling using appropriate screws
and anchors. -
Connect the wiring from the power supply to the downlight,
following electrical codes and guidelines. -
Securely attach the downlight to the direct box by twisting it
clockwise until it locks into place. -
Insert the twist lock diffuser back into position by twisting
it clockwise. -
Turn on the power supply and test the downlight to ensure
proper functionality.
Light Temperature Selection
The RSDS Surface Mount LED Downlight offers CCT Selectable
technology, allowing you to choose from different light
temperatures. Follow the steps below to select your desired light
temperature:
-
Ensure the downlight is connected to a power supply and turned
on. -
Using a compatible dimmer switch, cycle through the available
light temperature options (2700K, 3000K, 3500K, 4000K, 5000K) until
you reach your desired setting. -
The downlight will adjust its light output to match the
selected temperature.
Frequently Asked Questions (FAQ)
Q: Can I use a dimmer switch with the RSDS Surface Mount LED
Downlight?
A: Yes, the RSDS downlight is compatible with dimmer switches.
Refer to the “Recommended Dimmers” section for a list of compatible
dimmer models.
Q: Can I install the RSDS downlight in a non-metallic junction
box?
A: Yes, the RSDS downlight is compatible with most standard 4″
non-metallic or 4/O junction boxes. Ensure that the chosen junction
box meets electrical codes and guidelines.
Q: How do I change the light temperature of the RSDS
downlight?
A: The RSDS downlight offers CCT Selectable technology. Simply
cycle through the available light temperature options using a
compatible dimmer switch until you reach your desired setting.
RSDS
Surface Mount LED Downlight
Product Description
The RSD Selectable Surface Mount Downlight offers a thin installation solution
designed to fit the tightest of spaces. Installation is easier than ever with
the twist lock diffuser that can be removed for installation. The direct box
mount ensure it sits flush to the ceiling for a clean and professional look.
CCT Selectable with 2700/3000/3500/4000/5000K allows tailoring to the desired
light temperature. Perfect for bringing even illumination to any area of your
home.
Construction · Stamped steel body · Twist-lock diffuser allows for easy
removal for installation
Optical System · Molded polymer, UV stabilized diffuser maximizes light
output. · Convex diffuser creates uniform light distribution while reducing
glare · Offered in 5CCT selection of 2700K, 3000K, 3500K, 4000K, or 5000K
Electrical · Input voltage of 120VAC, 60Hz · CCT switch located under lens ·
Dimmable to 5% with compatible leading edge (TRIAC) and trailing edge (ELV)
dimmers · Operating temperature rating of -4°F to 104°F (-20°C to 40°C)
Finish · White powder coat finish standard · Optional colors of Black, Nickel,
or Oil-rubbed Bronze
Mounting and Installation · Easy installation in any 4″ pancake, 4″ non-
metallic or 4/O junction box · Keyhole mounting slots allow for quick
installation to junction boxes · For installations where power surge may be
possible, NICOR recommends installing additional surge protection at the
electrical distribution panel
Listings · cETLus 1598 Listed for wet locations · ENERGYSTAR Listed · CA Title
24/JA8 Compliant · Compliant with NFPA® 70, NEC® Section 410.16 (A)(3) and
410.16 (C)(5) for closet use · RoHS Compliant · Meets FCC Part 15, Subpart B,
Class B standards for conducted and radiated emissions · TM-21 Reported
L70(9k) life >54,000 hours · LM-79, LM-80 testing performed in accordance with
IESNA standards
Warranty · 5-year limited system warranty standard · Warranty does not cover
product failure due to an overvoltage event (power surge)
Project Catalog Type Date
RSDS
4″, 6″, 8″ Surface Mount LED Downlight 600, 900, 1100 lumen
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com December 23, 2022 9:07 AM RSDS Rev 1
Ordering
Ordering Information
Series
Version
RSD4
1
RSD56
RSD8
Specifications and dimensions subject to change without notice
Voltage 120
CCT’s S (2700/3000/3500/4000/5000K)
Example: RSD561120SWH Trim Color
WH (White) BK (Black) NK (Nickel) OB (Oil-rubbed Bronze)
Performance Data
Performance Data
Model Number RSD4S – 2700K RSD4S – 3000K RSD4S – 3500K RSD4S – 4000K RSD4S – 5000K RSD56S – 2700K RSD56S – 3000K RSD56S – 3500K RSD56S – 4000K RSD56S – 5000K RSD8S – 2700K RSD8S – 3000K RSD8S – 3500K RSD8S – 4000K RSD8S – 5000K
Lumens 613 655 643 676 633 921 999 1016 1025 999 1148 1264 1279 1298 1253
Watts 10.89 10.90 10.53 10.89 10.66 15.36 15.41 15.31 15.41 15.40 18.67 18.73 18.56 18.72 18.70
Lumens/Watt 56.3 60.1 61.1 62..1 59.3 60.0 64.8 66.4 66.5 64.9 61.4 67.5 68.9 69.3 67.0
Recommended Dimmers*
Housing Compatibility*
Lutron Diva DVCL-153P Lutron Maestro MACL-153M
Eaton Cooper SLC03P Leviton IPL06
Lutron DIVA DVELV-300P
MOST STANDARD 4″ NON-METALLIC OR 4/O JUNCTION BOXES
*Not a complete list. Check compatibility before installation.
Photometric Data
RSD4S 2700K
Input Voltage (VAC) System Level Power (W) Delivered Lumens (Lm) System Efficacy (Lm/W) Correlated Color Temp (K) Color Rendering Index (CRI) Beam Angle Spacing Criteria
120V 10.9 613 56.2 271 93 R9=60 111.6 1.26
CCT Data Multiplier
3000K 3500K 4000K 5000K
1.067 1.049 1.102 1.031
208
Intensity Summary
Cone of Light Tabulation
(Candle Power)
156
Mounted height
Footcandles
Diameter
Angle
Mean CP
(Feet)
Beam Center
(Feet)
104
0
208
4
13.0
11.8
52
5
207
15
199
6
5.8
17.7
8
3.2
23.5
25
185
10
2.1
29.4
35
163
45
137
55
107
Zonal Lumen Summary
65
76
75
45
85
20
90
12
Zone
0-30 0-40 0-60
Lumens
161 262 463
% of Luminaire
26.2% 42.8% 75.5%
0-90
613
100%
90-180
0
0%
0-180
613
100%
Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com December 23, 2022 9:07 AM RSDS Rev 1
Photometric Data
RSD56S 2700K
Input Voltage (VAC) System Level Power (W) Delivered Lumens (Lm) System Efficacy (Lm/W) Correlated Color Temp (K) Color Rendering Index (CRI) Beam Angle Spacing Criteria
120V 15.4 921 59.8 2690 93 R9=60 113.0 1.27
CCT Data Multiplier
3000K 3500K 4000K 5000K
1.085 1.103 1.113 1.085
RSD8S 2700K
Input Voltage (VAC) System Level Power (W) Delivered Lumens (Lm) System Efficacy (Lm/W) Correlated Color Temp (K) Color Rendering Index (CRI) Beam Angle Spacing Criteria
120V 18.7 1148 61.4 2694 93 R9=58 113.4 1.26
CCT Data Multiplier
3000K 3500K 4000K 5000K
1.101 1.114 1.131 1.092
Dimensions
308
Intensity Summary
Cone of Light Tabulation
(Candle Power)
231
Mounted height
Footcandles
Diameter
Angle
Mean CP
(Feet)
Beam Center
(Feet)
154
0
307
4
19.2
12.1
5
306
6
8.5
18.1
77
15
296
8
4.8
24.2
25
275
10
3.1
30.2
35
245
45
207
55
163
Zonal Lumen Summary
65
117
75
69
85
31
90
17
Zone 0-30 0-40 0-60
Lumens 238 390 692
% of Luminaire 25.9% 42.4% 75.1%
0-90
921
100%
90-180
0
0%
0-180
921
100%
Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.
385
Intensity Summary
Cone of Light Tabulation
(Candle Power)
289
Mounted height
Footcandles
Diameter
Angle
Mean CP
(Feet)
Beam Center
(Feet)
192
0
384
4
24.0
12.2
5
383
6
10.7
18.3
96
15
369
8
6.0
24.4
25
343
10
3.8
30.4
35
305
45
258
55
203
Zonal Lumen Summary
65
144
75
85
85
35
90
17
Zone 0-30 0-40 0-60
Lumens 299 489 869
% of Luminaire 26% 42.6% 75.7%
0-90
1148
100%
90-180
0
0%
0-180
1148
100%
Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.
D H
Fixture RSD4S RSD56S RSD8S
Dimensions
Diameter (D) 6.2″ (157mm) 7.4″ (188mm) 9.4″ (240mm)
Height (H) 1.2″ (31mm) 1.3″ (34mm) 1.3″ (34mm)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: –Reorient or relocate the receiving antenna. –Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help.
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com December 23, 2022 9:07 AM RSDS Rev 1