Product Information
Specifications
- Model : IS540.2
- Manufacturer: i.safe MOBILE GmbH
- Address : i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
- Contact : Tel. +49 9343 60148-0, info@isafe-mobile.com
- Website : www.isafe-mobile.com
- Version: 2023-11-16
EX Markings
EU Type Examination Certificate: EPS 23 ATEX 1 013 X
CE-designation
North America (NEC500 ):
- Class I Division 2 Group ABCD T4
- Class II Division 2 Group FG T4
- Class III Division 2 T4 LR3081
Product Compliance for North America
Conforms to:
- STD UL 60079-0
- STD UL 60079-11
- STD UL 913
Certified to :
- CSA STD CSA C22.2 No. 60079-0
- CSA STD CSA C22.2 No. 60079-11
Ex-Relevant Safety Regulations
Use of this device assumes that the operator observes the conventional safety regulations and has read and understood the Operating Manual, Safety Instructions, and certificate.
When used in explosion-hazardous areas, the following Safety Instructions must also be complied with:
- Inside explosion hazardous areas the covers of all interfaces (USB, ISM Interface) must be closed.
- Within explosion-hazardous areas, the following accessories may be used when connected to the ISM interface:
- The Headset IS-HS2A.1
- The Headset IS-HDHS1x.1
- The PTT Button IS-PTTB1A.1 together with the Headset IS-HDHS1x.1 The PTT Button IS-PTTB1A.1 without Headset IS-HDHS1x.1
- Other accessories approved by i.safe MOBILE GmbH The 16-pin ISM connector of the accessory must be securely fastened to the ISM interface.
- If the PTT Button IS-PTTB1A.1 is connected to the ISM interface of the device together with the Headset IS-HDHS1x.1, the connection between the IS-PTTB1A.1 and the Headset ISHDHS1x.1 can be disconnected and reconnected in explosion hazardous areas.
- When using the IS-PTTB1A.1 without the Headset IS-HDHS1x.1, the unused cable end of the IS-PTTB1A.1 may remain open in explosion hazardous areas.
- When using accessories with Velcro fasteners (e.g. Headset IS-HDHS1B.1), the Velcro fastener may only be adjusted outside explosion hazardous areas.
- To ensure the IP protection, it has to be ensured that all gaskets are present and functional. There must be no large gap between the two halves of housing and between the battery and housing.
Product Usage Instructions
Safety Instructions
When using the product, it is important to follow these safety instructions:
- Observe conventional safety regulations
- Read and understand the Operating Manual, Safety Instructions, and certificate
- Covers of all interfaces (USB, ISM Interface) must be closed inside explosion hazardous areas
Using Accessories
Within explosion-hazardous areas, the following accessories may be used when connected to the ISM interface:
- The Headset IS-HS2A.1
- The Headset IS-HDHS1x.1
- The PTT Button IS-PTTB1A.1 together with the Headset IS-HDHS1x.1
- The PTT Button IS-PTTB1A.1 without Headset IS-HDHS1x.1
- Other accessories approved by i.safe MOBILE GmbH
When using the accessories, make sure to :
- Securely fasten the 16-pin ISM connector of the accessory to the ISM interface
- If using the PTT Button IS-PTTB1A.1 with the Headset IS-HDHS1x.1, the connection between them can be disconnected and reconnected in explosion hazardous areas
- If using the IS-PTTB1A.1 without the Headset IS-HDHS1x.1, the unused cable end of the IS-PTTB1A.1 may remain open in explosion hazardous areas
- Adjust accessories with Velcro fasteners (e.g. Headset IS-HDHS1B.1) only outside explosion hazardous areas
Maintaining IP-Protection
To ensure the IP-protection of the device, follow these guidelines:
- Ensure all gaskets are present and functional
- Avoid large gaps between the two halves of the housing and between the battery and housing
FAQ
- What should I do if there is a fault or damage to the device?
- If there is any reason to suspect that the safety of the device has been compromised, it must be withdrawn from use and removed from any ex-hazardous areas immediately. Measures must be taken to prevent any accidental restarting of the device. We recommend that a device displaying errors or in which an error is suspected be sent back to i.safe MOBILE GmbH to be checked.
- Where can I find the FCC/IC declaration?
- The FCC/IC declaration can be found at www.isafe-mobile.com/en/support/downloads
- Can I adjust the Velcro fastener of accessories inside explosion hazardous areas?
- No, the Velcro fastener of accessories, such as the Headset IS-HDHS1B.1, should only be adjusted outside explosion hazardous areas.
EX MARKINGS
ATEX :
- II 3G Ex ic IIC T4 Gc
- II 3D Ex ic IIIC T135°C Dc
- EU Type Examination Certificate:
- EPS 23 ATEX 1 013 X
- CE-designation:
IECEx :
- Ex ic IIC T4 Gc
- Ex ic IIIC T135°C Dc
- IECEx Certificate: IECEx EPS 23.0003X
North America (NEC500):
- Class I Division 2 Group ABCD T4
- Class II Division 2 Group FG T4
- Class III Division 2 T4
- LR3081
Temperature range:
- 20°C … +55°C (EN/IEC 60079-0)
- 10°C … +55°C (EN/IEC 62368-1)
Manufactured by:
- i.safe MOBILE GmbH
- i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany
PRODUCT COMPLIANCE FOR NORTH AMERICA
- Conforms to : STD UL 60079-0, STD UL 60079-11, STD UL 913
- Certified to : CSA STD CSA C22.2 No. 60079-0, CSA STD CSA C22.2 No. 60079-11
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and has read and understood Operating Manual, Safety Instructions and certificate. When used in explosion hazardous areas, the following Safety Instructions must also be complied with:
- Inside explosion-hazardous areas the covers of all interfaces (USB, ISM Interface) must be closed.
- Within explosion hazardous areas, the following accessories may be used when connected to the ISM interface:
- the Headset IS-HS2A.1
- the Headset IS-HDHS1x.1
- the PTT Button IS-PTTB1A.1 together with the Headset IS-HDHS1x.1
- the PTT Button IS-PTTB1A.1 without Headset IS-HDHS1x.1
- other accessories approved by i.safe MOBILE GmbH.
- The 16-pin ISM connector of the accessory must be securely fastened to the ISM interface. If the PTT Button IS-PTTB1A.1 is connected to the ISM interface of the device together with the Headset IS-HDHS1x.1, the connection between the IS-PTTB1A.1 and the Headset ISHDHS1x. 1 can be disconnected and reconnected in explosion hazardous areas.
- When using the IS-PTTB1A.1 without the Headset IS-HDHS1x.1, the unused cable end of the IS-PTTB1A.1 may remain open in explosion-hazardous areas.
- When using accessories with Velcro fasteners (e.g. Headset IS-HDHS1B.1), the Velcro fastener may only be adjusted outside explosion hazardous areas. To ensure the IP-protection, it has to be ensured that all gaskets are present and functional. There must be no large gap between the two halves of housing and between the battery and housing.
- The device may only be charged outside explosion hazardous areas using the charging equipment approved by i.safe MOBILE GmbH.
- The microSD cards type IS-SD164.1 and IS-SD1128.1 or microSD cards which comply with the intrinsic safety entity parameters mentioned in the certificate, may be used in the corresponding slot in the hazardous area.
- Nano-SIM cards which comply with the intrinsic safety entity parameters mentioned in the certificate, may be used in the corresponding slot in the hazardous area. The device may only be charged at ambient temperatures between 0°C … +45°C. The device may not be exposed to any aggressive acids or alkalis. The device may only be used in zones 2 or 22.
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
WARNING
- The battery may only be charged and replaced outside of the hazardous area only.
- Only charge the device using charging equipment approved by i.safe MOBILE GmbH.
- The device must be protected from impacts with high impact energy, against excessive exposure to UV light and high electrostatic discharge.
- The covers of all interfaces (USB, ISM interface) must be closed.
- The device is intended to be carried over during use in the hazardous area.
- The Headsets IS-HS2A.1, IS-HDHS1x.1 and the PTT Button IS-PTTB1A.1 or other accessories approved by i.safe MOBILE GmbH may be used within explosion hazardous areas only if connected to the ISM interface. The connector must be securely fastened to the ISM interface.
- The microSD cards IS-SD164.1 and IS-SD1128.1 may be used in the corresponding slot in the hazardous area. Alternatively, the SD card port has the following intrinsic safety entity parameters:
- Uo/Voc=4.35 V
Co/Ca=80 μF
Lo/La=1 μH
A commercially available microSD card may be used in the corresponding slot in potentially explosive atmospheres. The internal electrical capacitance and inductance are negligible, respectively correspond to the intrinsically safe connection parameters.
- Nano-SIM cards which comply with the following intrinsic safety entity parameters, may be used in the corresponding slots in the hazardous area:
Uo/Voc=4.35 V
Co/Ca=80 μF
Lo/La=1 μH
A commercially available nano-SIM card may be used in the corresponding slot in potentially explosive atmospheres. The internal electrical capacitance and inductance are negligible, respectively correspond to the intrinsically safe connection parameters.
FAULTS AND DAMAGES
If there is any reason to suspect that the safety of the device has been compromised, it must be withdrawn from use and removed from any ex-hazardous areas immediately. Measures must be taken to prevent any accidental restarting of the device. The safety of the device may be compromised, if, for example:
- Malfunctions occur.
- The housing of the device shows damage.
- The device has been exposed to excessive loads.
- The device has been stored improperly
- Markings or labels on the device are illegible.
We recommend that a device displaying errors or in which an error is suspected be sent back to i.safe MOBILE GmbH to be checked.
INFORMATION CONCERNING SAR CERTIFICATION
(SPECIFIC ABSORBATION RATE)
The SAR limit of Europe is 2,0 W/kg for the head and body, 4,0 W/kg for the limbs. The devicehas been tested against this SAR limit. The highest SAR value reported under this standard during product certification for use at the ear is 1,27 W/kg and when correctly worn on the body is 1,23 W/kg, limbs is 2,3 W/kg.
This device was tested for typical body worn operations with the back of the handset kept 5 mm from the body. The device complies with RF specifications when used at 5 mm from the body. Belt clips, holsters and similar accessories used should not contain metallic components in the assembly. The use of accessories that do not satisfy these requirements may not comply with RF exposure requirements, and should be avoided.
FCC/IC STATEMENT
The FCC/IC declaration can be found at www.isafe- mobile.com/en/support/downloads
MAXIMUM OUTPUT POWER
| AT| BE| BG| CH| CY| CZ| DE
---|---|---|---|---|---|---|---
DK| EE| EL| ES| FI| FR| HR
HU| IE| IS| IT| LI| LT| LU
LV| MT| NL| PL| PT| RO| SE
SI| SK| TR| UK| | |
Restrictions in the 5 GHz band:
According to Article 10 (10) of Directive 2014/53/EU, the packaging shows that this radio equipment will be subject to some restrictions when placed on the market in Belgium (BE), Bulgaria (BG), the Czech Republic (CZ), Denmark (DK), Germany (DE), Estonia (EE), Ireland (IE), Greece (EL), Spain (ES), France (FR), Croatia (HR), Italy (IT), Cyprus (CY), Latvia (LV), Lithuania (LT), Luxembourg (LU), Hungary (HU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania (RO), Slovenia (SI), Slovakia (SK), Finland (FI), Sweden (SE), the United Kingdom (UK), Turkey (TR), Norway (NO), Switzerland (CH), Iceland (IS), and Liechtenstein (LI). The WLAN function for this device is restricted to indoor use only when operating in the 5150 to 5850 MHz frequency range.
EU Declaration of Conformity
according to directive 2014/34/EU, 2014/53/EU, 2011/65/EU (2015/863/EU)
The company i.safe MOBILE GmbH declares under its sole responsibility that the product to which this declaration relates is in accordance with the provisions of the following data, directives and standards:
Name & address of the manufacturer in the EU | i.safe MOBILE GmbH |
---|
Description of the device
Accessories
| Explosion-protected smartphone Smartphone Type /: IS540.2
Model / : M540A01
__
Battery
Type /: BPIS540.2A Model / : MBP540A01
__
Power supply unit / ICP12-050-2000B Headset / : IS-HS2A.1
Ex – marking| II 3G Ex ic IIC T4 Gc
II 3D Ex ic IIIC T135°C Dc
Conformity statement 2014/34/EU issued by| EPS 23 ATEX 1 013 X
__
Bureau Veritas Consumer Products Services Germany GmbH
Businesspark A96
Germany
identification number / : 2004
Applied harmonized standards| EN IEC 60079-0:2018; EN 60079-11:2012
Conformity statement 2014/53/EU| EN 62368-1:2020+A11:2020;
EN 50332-1:2013; EN 50360:2017;
EN 50566:2017; EN 62209-1:2016; EN 62209-2:2010+A1:2019;
EN 62479:2010; EN 50663:2017;
EN IEC 62311:2020
ETSI EN 301 489-1 V2.2.3;
ETSI EN 301 489-3 V2.3.0;
ETSI EN 301 489-17 V3.2.5;
ETSI EN 301 489-19 V2.2.1;
ETSI EN 301 489-52 V1.2.1; EN 55032:2015+A11:2020; EN 55035:2017+A11:2020; ETSI EN 301 511 V12.5.1;
ETSI EN 301 908-1 V15.1.1;
ETSI EN 301 908-2 V13.1.1;
ETSI EN 301 908-13 V13.2.1;
Draft ETSI EN 301 908-25 V15.1.1_0.0.9;
ETSI EN 300 328 V2.2.2;
ETSI EN 301 893 V2.1.1;
ETSI EN 300 440 V2.2.1;
ETSI EN 300 330 V2.1.1;
ETSI EN 303 413 V1.2.1;
ETSI TS 103 625 V1.2.1;
ISO/IEC 18305 2016 (E);
ETSI TS 103 246-3 V1.3.1;
ETSI TS 103 246-5 V1.3.1;
ETSI EN 303 413 V1.2.1
---|---
Conformity statement 2015/863/EU amending 2011/65/EU| IEC 62321-2:2021; IEC
62321-1:2013;
IEC 62321-3-1:2013; IEC 62321-5:2013; IEC 62321-4:2013+A1:2017;
IEC 62321-7-1:2015;
IEC 62321-7-2:2017 & ISO 17075-1:2017;
IEC 62321-6:2015: IEC 62321-8:2017
CE Marking|
- Lauda – Koenigshofen 19.10.2023 Dirk Amann Managing Director
- 1060CC05REV01_cmu All rights reserved, i.safe MOBILE GmbH
- WWW.ISAFE-MOBILE.COM
contacts
- IS540.2 | MODEL M540A01
- Document No. 1060MM11REV02
- Version : 2023-11-16
- i.safe MOBILE GmbH i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany
- Tel. +49 9343 60148-0
- info@isafe-mobile.com
- www.isafe-mobile.com
- (c) 2023 i.safe MOBILE GmbH
References
- Zertifizierte Smartphones, Tablets und Mobiltelefone für IECEx und ATEX Zonen
- Betriebsanleitungen, Produktflyer, Datenblätter uvm.
- Datasheets, Manuals, Certificates and Product Folders
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>