INSTRUCTIONS FOR SAFETY AND USE
Further information on Novy products, accessories, and services may be found
on the internet: www.novy.co.uk These are the
installation instructions for the appliance shown on the front.
These directions for use make use of a number of symbols. The meanings of the
symbols are shown below.
Symbol | Meaning | Action |
---|---|---|
Indication | Explanation of an indication on the device. | |
Warning | This symbol indicates an important tip or a dangerous situation |
Warnings before installation
-
Read the directions for use and the installation instructions before installing and using this appliance. You will find important information here for the assembly and
use of the appliance. -
The appliance is intended exclusively for household use (preparation of food) and excludes all other domestic, commercial or industrial use. Do not use the appliance outside.
-
Keep good care of this manual and pass it on to any person who may use the appliance after you.
-
This appliance complies with the applicable safety instructions. However, inexpert installation may cause personal injury or damage to the appliance.
-
Check the condition of the appliance and the installation fittings as soon as you remove them from the packaging. Remove the appliance from the packaging with care. Do not use sharp knives to open the packaging.
-
Do not install the appliance if it is damaged, and in that case inform Novy.
-
Check on the basis of drawing A that all the materials for installation have been supplied.
-
Novy is not liable for damage resulting from incorrect assembly, incorrect connection, incorrect use, or incorrect operation.
-
Safety is guaranteed only with expert installation in accordance with the installation manual. The installing technician is responsible for proper operation at the installation location.
-
Metal parts may have sharp edges, and you may injure yourself on them. For that reason, wear protective gloves during installation.
-
Do not convert or alter the appliance.
-
Remove labels and stickers on the appliance with tips for use or installation. The type sticker is to be found behind the grease filter in the appliance. Do not remove it.
THE MONOBLOCK RECIRCULATION FILTER
Contemporary, energy-efficient kitchen ventilation: you can’t have the first
without the latter. Recirculation offers the solution for this. Recirculation
extraction hoods do not remove the cooking fumes, but filter the odor and fat
out of the air and then blow the filtered air back into the home.
The Novy monoblock filter absorbs unpleasant odors and makes the removal of
hot air to the outside unnecessary. The basis of the monoblock filter is an
advanced form of activated carbon particles in the shape of minuscule spheres
that are bonded to a load-bearing labyrinth structure. Due to the labyrinth
structure, the monoblock filter has a limited loss of pressure and maintains
maximum efficiency. This results in efficient extraction, excellent odor
absorption, and a limited noise level.
USE OF THE MONOBLOCK RECIRCULATION FILTER
The monoblock filter is used in combination with a cooker hood/hood or worktop extractor.
Before programming and using the recirculation mode, read the operating
instructions of your device.
For optimal operation of the monoblock recirculation filter, it is important
to switch on the extractor before cooking and to respect the after-running
time. To do this, read the instructions in the operating instructions for your
appliance.
Provide adequate ventilation in the kitchen for optimal efficiency of the
recirculation system.
An indication on the cooker hood or downdraft extractor indicates that the
Monoblock recirculation filter needs to be replaced.
The lifetime of this Monoblock recirculation filter is indicated on the label
on the filter itself.
You can obtain a new monoblock filter from specialist retailers or via the Novy website. Article number monoblock filter: 7600060.
Installation materials recirculation kit
Important: Please read the safety and installation instructions before you start.
Cooker hood installation materials
INSTALLATION
1 Preparation for mounting: Draw the vertical axis A of the chimney hood on
the wall. The recommended height ‘h’ between the bottom of the chimney hood
and the cooking plate is for
• The recommended mounting height for an electrical or ceramic cooking plate
is min. 600 mm and max. 750 mm.
• The mounting height for a gas or induction cooking plate is min. 650 mm and
max. 750 mm.
The level line B is drawn at the chosen height of ‘h’ + 440 mm.
Position the socket outlet near the vertical axis A within the width of the
shafts and above the motor housing and below the recirculation box (M).
2 3 Position the mounting plate (M) of the recirculation box in the middle of
the vertical axis and against the ceiling. In the case of a stone wall, mark
and drill the 3 holes (Ø 8 mm). Install the mounting plate (M) using the
plugs (3x 906-055) and screws (3x 906-143). In case of a wooden mounting wall,
use the chipboard screws (3 x 906-192).
4 5 Position the recirculation box (H) on the mounting plate (M). Make sure
when positioning the recirculation box that it is not deformed or unfolded
when mounting.
1. Let H rest on the protruding lip of M (see 5 ).
2. Tilt H towards the wall bracket M.
3. Hook the lip of H behind the wall bracket M.
6 7 Screw the recirculation box H onto the mounting plate M (4x 906-151).
Make sure that the attachment lip of H is always on the outside!
After having mounted the recirculation box, the wall-mounted chimney hood can
be mounted. Use the mounted materials supplied with the chimney hood for
mounting the hood and the shafts.
8 The drilling jig is to be found in the mounting instructions of the wall-
mounted hood. Place this drilling jig on the crossing point of axis A and the
level line B and draw the 2 holes on the level line. Drill holes in the wall
using an 8 mm drill.
9 Use the large plugs (906055) and partly screw the accompanying large screws
(906143) into the wall. Attention: do not fully screw in the screws yet!
Hang the wall-mounted chimney hood with the bracket on top of the motor
housing over these screws.
10 11 Level the chimney hood C by turning the screws on the chimney hood such,
that the chimney hood is hanging level. The height of the chimney hood can
slightly be adjusted by screwing the screws in and out.
Do not tighten the screws in the wall yet!
12 Open the bottom panel and remove the grease filter from the chimney hood.
There are 2 holes on the rear side of the chimney hood. Mark these holes on
the wall. Close the bottom plate and take the chimney hood off the wall in
order to be able to drill the marked holes. Drill the holes with a 6 mm drill
and use the small plugs (906115). Position the chimney hood against the wall
again. Check if the hood is still hanging level. Use the small screws (906197)
to properly attach the wall-mounted chimney hood to the wall. Now also tighten
the screws above in the wall.
13 Install the lower spacer bracket on the vertical axis 100 mm from the
upper side of the mounting bracket to the center of the drilled hole. Use the
plugs (906115) and the screws (906197). Mount the spacer bracket such, that it
is perpendicular to and in the center of the vertical axis on the wall.
14 Place the supplied exhaust pipe (906-217) onto the connection nozzle using
the supplied aluminum tape (906-292) or using a hose clamp (not included).
Extend the exhaust pipe until against the inlet of the carbon filter box and
fix it with aluminum tape or a hose clamp. Then put the plug into the socket
outlet.
15 Remove the shaft set from the packaging of the hood. Slide the upper shaft
out of the lower shaft and turn it around, so the grate is at the top. Slide
the upper shaft back into the lower shaft.
Move the shafts beyond the recirculation box unto the ceiling and then push
them behind the recirculation box!
16 Lower the outer shaft unto the chimney hood. Clamp the outer shaft onto the
lower spacer. Open the bottom plate and remove the filter from the chimney
hood. Tighten the shaft from the inside of the chimney hood with the 4 screws
(906151).
17 Push the upper shaft behind the carbon filter box. Then tighten them using
the corresponding stainless steel screws (2 x 906-035).
Install the Monoblock recirculation filter
18 Open the bottom panel and remove the aluminum
grease filter from the chimney hood.
19 Place the Monoblock recirculation filter (7600060) in the opening provided.
20 Put the grease filter back in the cooker hood.
Stick the sticker indicating the service life of this monoblock filter next to
the opening of the grease filter.
Close the lower panel.
**** When selecting recirculation, always set the recirculation program on
the extractor hood.
To do so, read the instructions in the operating instructions of your
appliance.
NOVY NV reserves the right at any time and without reservation to change the structure and the prices of its products.
Novy
7600400
✓ Flatline
7600/7602/7610/7612
Noordlaan 6
B – 8520 KUURNE
Tel. 056/36.51.00
Fax 056/35.32.51
E-mail:novy@novy.be
www.novy.be
www.novy.com
United Kingdom: +44 (0)207 866 2493
References
- Der Spezialist für Dunstabzugshauben und Kochfelder - Novy
- Innovatieve dampkappen en intuïtieve kookplaten - Novy
- Specialist in cooker hoods and hobs - Novy
- Specialist in cooker hoods and hobs | Novy - Novy
- Spécialiste des hottes et tables de cuisson - Novy
- Specialist in stijlvolle afzuigkappen en kookplaten - Novy
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>