legrand P116W Old Work Switch and Outlet Box Instruction Manual

June 16, 2024
Legrand

legrand P116W Old Work Switch and Outlet Box

Specifications

  • Mounting: Frame mount
  • Wall thickness: 1/8 to 1-1/16
  • Cut Out Dimensions:
    • TV1W: 4-1/8 x 6-3/8
    • TV3W: 7-3/4 x 6-3/8
  • Electrical Box Compatibility: P116W, S116W, M118W & S118W
  • Wall Plate Dimensions: Max 4-7/8 x 3 (Recommended: P&S TP wall plates)

Product Usage Instructions

Frame Mounting Instructions

  1. Place the frame facing the wall in the desired location and mark the wall through the provided slots. Ensure there are no obstructions behind the wall before cutting.
  2. Connect the marks and cut out the wall surface using the specified dimensions for the TV1W or TV3W models.
  3. Place the frame into the cutout and turn the screws clockwise to tighten it against the wall.
  4. Insert P&S SignatureTM end-cap tabs and firmly push to snap them on. To remove the end-caps, insert a small flat screwdriver into each notch and gently pry off.

Line Voltage Installation

  1. Use a P&S old work electrical box for installation. Recommended options are P116W, S116W, M118W & S118W. Check for clearances before installation to ensure proper fit.
  2. Pull the cable through to the desired length.
  3. Insert the electrical box into the frame opening with the swing brackets flat to the box and turn the screws clockwise until snug to the frame.
  4. Install UL-listed electrical devices according to the manufacturer’s instructions.
  5. Use UL-listed wall plates to complete the installation. The recommended dimensions for the wall plates are 4-7/8 x 3 (Recommended: P&S TP wall plates).

Low Voltage Installation

  1. Install green low voltage brackets, with text facing out as shown in figures 2-4.
  2. Pull the low voltage wiring through the desired opening and wire terminate to keystone multimedia jacks according to the manufacturer’s instructions.
  3. Push excess wire back through the frame and mount the jack to a low-voltage wall plate or low-voltage insert provided.
  4. Install wall plates as needed. (Wall plate is NOT needed for TV1W B opening.)

Catalog Number(s)

  • Country of Origin: Assembled in the USA

WARNING: To prevent severe shock or electrocution, always turn the power OFF at the service panel before installing this unit, working on the circuit, or changing a lamp.

FRAME MOUNTING INSTRUCTIONS

Note: The unit to be installed on a finished wall, with a thickness of 1/8″ to 1-1/16″. Be sure there are no obstructions behind wall surface, such as wall studs

  1. Place the Frame facing the wall in the desired location and mark the wall through the slots provided. Make sure there are no obstructions behind wall before cutting.

  2. Connect the marks and cut out the wall surface.
    Cut Out Dimensions:

    • TV1W: 4-1/8″ x 6-3/8″
    • TV3W: 7-3/4″ x 6-3/8″
  3. Place the Frame into the cutout. Turn the screws clockwise. Tighten until snug against the wall.

  4. Insert P&S Signature™ end-cap tabs and firmly push to snap on.
    Note: To remove Signature™ end-caps, insert a small flat screwdriver into each notch and gently pry off. See figure 1

  5. A) Line Voltage or Low Voltage Mounting Capable. Use appropriate installation instructions.

  6. B) Low Voltage Only. Use keystone jacks for hard-wired terminations. www.legrand.us (full line of keystone jack options.)

LINE VOLTAGE INSTALLATION

  1. A P&S old work electrical box must be used. P116W, S116W, M118W & S118W are recommended for best fit. Check for clearances before installation to ensure proper fit. Centre opening on TV3W may not be suitable for line voltage in all applications. (2×4 wall construction)
  2. Pull the cable through the desired opening. Insert the nonmetallic cable into the Auto/Clamp® cable entry in the old work box, or under the metal clamp in M118W.
  3. Pull the cable through to the desired length.
  4. Insert the electrical box into the Frame opening with the swing brackets flat to the box and turn the screws clockwise until snug to the Frame.
  5. Install UL-listed Electrical devices per the manufacturer’s instructions.
  6. Use UL-listed wall plates to complete the installation. Note: Max wall plate dimensions: 4-7/8″ x 3″ (Recommended: P&S TP wall plates)

LOW VOLTAGE INSTALLATION

  1. Install green low voltage brackets, with text facing out as shown in figures 2-4.
  2. Pull Low Voltage wiring through the desired opening and wire terminate to keystone multimedia jacks per manufacturer instructions.
  3. Push excess wire back through the Frame and mount the jack to the Low Voltage wall plate or Low Voltage insert provided.
  4. Install wall plates as needed. (Wall plate is NOT needed for TV1W “B” opening.)

FAQs

  • Q: Can this unit be installed on any wall thickness?
    • A: No, this unit is designed to be installed on a finished wall with a thickness of 1/8 to 1-1/16.
  • Q: How do I remove the SignatureTM end-caps?
    • A: To remove the SignatureTM end-caps, insert a small flat screwdriver into each notch and gently pry them off.
  • Q: Are wall plates included with the product?
    • A: Wall plates are not included with the product. UL-listed wall plates with dimensions of 4-7/8 x 3 are recommended.
  • Q: Can I use this unit for line voltage or low voltage installation?
    • A: Yes, this unit is capable of both line voltage and low voltage installation. Please follow the appropriate installation instructions.

860.233.4185
1.877.BY.LEGRAND
www.legrand.us