legrand P116W Old Work Switch and Outlet Box Instruction Manual
- June 16, 2024
 - Legrand
 
Table of Contents
legrand P116W Old Work Switch and Outlet Box
Specifications
- Mounting: Frame mount
 - Wall thickness: 1/8 to 1-1/16
 - Cut Out Dimensions:
- TV1W: 4-1/8 x 6-3/8
 - TV3W: 7-3/4 x 6-3/8
 
 - Electrical Box Compatibility: P116W, S116W, M118W & S118W
 - Wall Plate Dimensions: Max 4-7/8 x 3 (Recommended: P&S TP wall plates)
 
Product Usage Instructions
Frame Mounting Instructions
- Place the frame facing the wall in the desired location and mark the wall through the provided slots. Ensure there are no obstructions behind the wall before cutting.
 - Connect the marks and cut out the wall surface using the specified dimensions for the TV1W or TV3W models.
 - Place the frame into the cutout and turn the screws clockwise to tighten it against the wall.
 - Insert P&S SignatureTM end-cap tabs and firmly push to snap them on. To remove the end-caps, insert a small flat screwdriver into each notch and gently pry off.
 
Line Voltage Installation
- Use a P&S old work electrical box for installation. Recommended options are P116W, S116W, M118W & S118W. Check for clearances before installation to ensure proper fit.
 - Pull the cable through to the desired length.
 - Insert the electrical box into the frame opening with the swing brackets flat to the box and turn the screws clockwise until snug to the frame.
 - Install UL-listed electrical devices according to the manufacturer’s instructions.
 - Use UL-listed wall plates to complete the installation. The recommended dimensions for the wall plates are 4-7/8 x 3 (Recommended: P&S TP wall plates).
 
Low Voltage Installation
- Install green low voltage brackets, with text facing out as shown in figures 2-4.
 - Pull the low voltage wiring through the desired opening and wire terminate to keystone multimedia jacks according to the manufacturer’s instructions.
 - Push excess wire back through the frame and mount the jack to a low-voltage wall plate or low-voltage insert provided.
 - Install wall plates as needed. (Wall plate is NOT needed for TV1W B opening.)
 
Catalog Number(s)
- Country of Origin: Assembled in the USA
 
WARNING: To prevent severe shock or electrocution, always turn the power OFF at the service panel before installing this unit, working on the circuit, or changing a lamp.
FRAME MOUNTING INSTRUCTIONS
Note: The unit to be installed on a finished wall, with a thickness of 1/8″ to 1-1/16″. Be sure there are no obstructions behind wall surface, such as wall studs
- 
Place the Frame facing the wall in the desired location and mark the wall through the slots provided. Make sure there are no obstructions behind wall before cutting.
 - 
Connect the marks and cut out the wall surface.
Cut Out Dimensions:- TV1W: 4-1/8″ x 6-3/8″
 - TV3W: 7-3/4″ x 6-3/8″
 
 - 
Place the Frame into the cutout. Turn the screws clockwise. Tighten until snug against the wall.
 - 
Insert P&S Signature™ end-cap tabs and firmly push to snap on.
Note: To remove Signature™ end-caps, insert a small flat screwdriver into each notch and gently pry off. See figure 1 - 
A) Line Voltage or Low Voltage Mounting Capable. Use appropriate installation instructions.
 - 
B) Low Voltage Only. Use keystone jacks for hard-wired terminations. www.legrand.us (full line of keystone jack options.)
 
LINE VOLTAGE INSTALLATION
- A P&S old work electrical box must be used. P116W, S116W, M118W & S118W are recommended for best fit. Check for clearances before installation to ensure proper fit. Centre opening on TV3W may not be suitable for line voltage in all applications. (2×4 wall construction)
 - Pull the cable through the desired opening. Insert the nonmetallic cable into the Auto/Clamp® cable entry in the old work box, or under the metal clamp in M118W.
 - Pull the cable through to the desired length.
 - Insert the electrical box into the Frame opening with the swing brackets flat to the box and turn the screws clockwise until snug to the Frame.
 - Install UL-listed Electrical devices per the manufacturer’s instructions.
 - Use UL-listed wall plates to complete the installation. Note: Max wall plate dimensions: 4-7/8″ x 3″ (Recommended: P&S TP wall plates)
 
LOW VOLTAGE INSTALLATION
- Install green low voltage brackets, with text facing out as shown in figures 2-4.
 - Pull Low Voltage wiring through the desired opening and wire terminate to keystone multimedia jacks per manufacturer instructions.
 - Push excess wire back through the Frame and mount the jack to the Low Voltage wall plate or Low Voltage insert provided.
 - Install wall plates as needed. (Wall plate is NOT needed for TV1W “B” opening.)
 
FAQs
- Q: Can this unit be installed on any wall thickness?
- A: No, this unit is designed to be installed on a finished wall with a thickness of 1/8 to 1-1/16.
 
 - Q: How do I remove the SignatureTM end-caps?
- A: To remove the SignatureTM end-caps, insert a small flat screwdriver into each notch and gently pry them off.
 
 - Q: Are wall plates included with the product?
- A: Wall plates are not included with the product. UL-listed wall plates with dimensions of 4-7/8 x 3 are recommended.
 
 - Q: Can I use this unit for line voltage or low voltage installation?
- A: Yes, this unit is capable of both line voltage and low voltage installation. Please follow the appropriate installation instructions.
 
 
860.233.4185
1.877.BY.LEGRAND
www.legrand.us