TEST REPORT

Applicant: Duojiaen Foshan E-commerce CO.,Ltd.
Address: Rm 2,2312,Building 3,Yueran Plaza,Midea Real Estate,Foshan Guangdong 528300

The following merchandise was (were) submitted and identified by client as:

Sample Name: Hot water dispenser
Number   of Sample: 1SET
Style of Sample: AMZ-B-20,AMZ-B-15, AMZ-B-20B, AMZ-B-15B,AMZ20,AMZ-F-20,AMZ-F-15,AMZ-F-20B,AMZ-F-15B
Sample Received Date: Nov. 28, 2023
Completed Date: Dec. 01, 2023

Test Requested and Conclusion(s):

No. Test Sample(s) Standard(s) and Requirement(s) Conclusion(s) Signed by
**** 1 **** Submitted sample CPG Sec. 545.500 Silver-Plated Hollowware –
Lead Contamination (CPG 7117.05).- Leachable Lead(Pb) **** PASS ****
**** 2 **** Submitted sample General Recognized As Safe (GRAS)
specification for US FDA regulation on Stainless steel.- Total Chromium (Cr)

**** PASS

Test Result(s):

CPG 7117.05 – Leachable Lead (Pb)
Method: With reference to ASTM C738-94(2020), analyzed by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES).

Material No.| Sample(s)| Result(s)µg/mL )| Conclusion(s)
---|---|---|---
Leachable Lead(Pb)
Limit(s)µg/mL )| 7
2| (1)| 1.1| PASS
(2)| 1.2
(3)| 1.2
(4)| 1.2
(5)| 1.2
(6)| 1.2
Average| 1.2

Note: Volume of 4% Acetic acid used 242 mL.

CPG 7117.05 – Leachable Lead (Pb)
Method: With reference to ASTM C738-94(2020), analyzed by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES).

Material No.| Sample(s)| Result(s)µg/mL )| Conclusion(s)
---|---|---|---
Leachable Lead(Pb)
Limit(s)µg/mL )| 7
3| (1)| <0.1| PASS
(2)| <0.1
(3)| <0.1
(4)| <0.1
(5)| <0.1
(6)| <0.1
Average| <0.1

Note:

  1. Volume of 4% Acetic acid used 251 mL.
  2. If intended for use by adults, it releases in 6 units examined an average of 7 or moremicrograms lead/ml. of leaching solution.
  3. If intended exclusively for use by infants and children, it releases in one or more of 6unitsexamined 0.5 or more micrograms lead/ml of leaching solution.

Test Result(s):
General Recognized As Safe (GRAS) specification for US FDA regulation on Stainless steel – Total Chromium (Cr)n
Method: Acid digestion, analyzed by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES).

Material No.| RL% )| Limit(s)% )| Result(s)% )| Conclusion(s)
---|---|---|---|---
1| 0.001| >16| 18.13| PASS

Remark:

  1. µg/mL = microgram per milliliter.
  2. % = Percent by weight.
  3. RL = Report Limit.
  4. As per client’s request, only the appointed points and items have been tested.
  5. “n” = The test item is not accredited by CNAS.The result/conclusion is for referenceonly

Test Material List

Material No. Description(s) Location(s)
1 Silver metal Water tank/floating ball (304 stainless steel)
2 Silver metal Water outlet faucet
3 Coppery metal Heating copper tube

Photo(s) of Sample(s):
Description

The photo(s) submitted by client:
Overview

Report Remark

  1. 1. The company guarantees the scientificity, impartiality and accuracy, is responsible for test data, and keeps confidential for the samples and technical data provided.
  2. The information of the samples submitted for inspection is provided by applicant, and the company is not responsible for its authenticity or integrity.
  3. The results shown in this report refer only to the sample(s) submitted.
  4. This report is invalid without signature of approver, is invalid if not affixed with Authorized Stampof Test and Paging Seal. The data/results in reports without an CMA stamp ,all or part of items of this report arenot in the accredited scope of CMA cannot be as domestic social impartiality proof data. It canonlyusedfor research and development, teaching, internal quality control, and only for internal reference.
  5. Any unauthorized reproduced in part, Any way of piracy, alteration forgery of this report is unlawful.
  6. If there are any questions about the report, please contact us.
  7. Any dispute of this report must be raised to the center within 10 workdays since the date of receipt, or it will not be accepted.
  8. For samples with unstable performance, re-inspection will not be accepted

CONTACT US

Company Name: GUANGDONG WONDER TESTING INTERNATIONAL CO., LTD.
Contact Address: Floor 6, No.14, Gaoxin Road, Huadu District, Guangzhou City, GuangdongProvince, China
Tel: 86-020-8689 0001
Fax: 86-020-8689 6998
Post Code: 510820
Website: http://www.wdwonder.com

Scan by QR Code
QR Code

GUANGDONG WONDER TESTING INTERNATIONAL CO., LTD.

Floor 6, No.14,Gaoxin Road, Huadu District, Guangzhou City,Guangdong Province, China, 510820
E-mail: wd@wdwonder.com
Tel: 86-020-8689 0001
Fax: 86-020-8689 6998
Website: http://www.wdwonder.com

WONDER Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals