UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor User Guide

June 16, 2024
UBIQUITI NETWORKS

UBIQUITI NETWORKS logo NETWORKS NSM2
Wireless CPE Indoor Outdoor
User Guide

Package Contents

NSM2/NSM3/NSM365/NSM5

UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - Package
Contents

locoM2/locoM5

UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor -
locoM2

locoM9

UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor -
locoM9

Installation Requirements

  • Shielded Category 5 (or above) cabling with drain wire should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE.
    We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable

  • Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation and the other at the entry point to the building. The ETH-SP will absorb power surges and safely discharge them into the ground.UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - Hardware Overview

Hardware Overview

NSM2/NSM3/NSM365/NSM5/locoM2/locoM5

UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - Power
LED

  1. Power LED
    The LED will light green when the device is connected to a power source.
    The LED will light steady green when an active Ethernet connection is made to the Main/LAN port and flash when there is activity.

  2. LAN2 LED
    (NanoStation M2/M3/M5 only) The LED will light steady green when an active Ethernet connection is made to the Secondary port and flash when there is activity.

  3. Signal LEDs
    In airOS®, you can modify the threshold values for the wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds. The default values are shown below:

  4. Secondary Port
    (NanoStationM2/M3/M5 only) This 10/100 Ethernet port is used for bridging and supports software-configurable PoE passthrough.
    Note: To use PoE passthrough on the Secondary port, a 24V, 1A PoE adapter is required.

  5. *Main/LAN Port**
    This 10/100 Ethernet port is used to connect the power and should be connected to the LAN and DHCP server.

  6. Reset Button
    To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the PoE adapter.

  • The Main port is labeled LAN on the NanoStationlocoM2/M5.

locoM9
UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - The LED will light
green

  1. Power LED
    The LED will light green when the device is connected to a power source.

  2. LAN1 LED
    The LED will light steady green when an active Ethernet connection is made to the Main/LAN port and flash when there is activity.

  3. Signal LEDs
    In airOS®, you can modify the threshold values for the wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds. The default values are shown below:

  4. RP-SMA Antenna Connector
    Reserved for future use.

  5. Main/LAN Port
    This 10/100 Ethernet port is used to connect the power and should be connected to the LAN and DHCP server.

  6. Reset Button
    To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the PoE adapter.

Installation

  1. UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - Installation
  2. UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - fig1
  3. UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - fig2
  4. UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - fig3
  5. UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - fig4
  6. UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - fig5

Connecting Power

WARNING : The switch port must comply with the power specifications listed in this Quick Start Guide.

UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor - Connecting
Power

Optional

UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor -
Optiona

Accessing airOS

Verify connectivity in the airOS Configuration Interface.

  1. Make sure that your host system is connected via Ethernet to the device.

  2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.

  3. Launch your web browser and type https://192.168.1.20 in the address field.
    Press enter (PC) or return (Mac).

  4. Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Login.
    The airOS Configuration Interface will appear, allowing you to customize your settings as needed. For details, refer to the User Guide available at ui.com/download/airmax
    You can also manage your device using the Ubiquiti Internet Service Provider. Setup using the UISP™ app requires the U-Installer, sold separately.

Installer Compliance Responsibility

Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements.
The Antenna Gain and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements.

Specifications

NanoStationM2/M3/M365/M5

Dimensions| 294 x 30 x 80 mm
(11.57 x 1.18 x 3.15″)
Weight NSM2/NSM5 NSM3/NSM365| 0.4 kg (14.11 oz)
0.5 kg (17.64 oz)
Gain
NSM2 NSM3/NSM365 NSM5| 11 dBi
13.7 dBi
16 dBi
Networking Interface| (2) 10/100 Ethernet Ports
Max. Power Consumption| 8W
Power Supply| 24V, 0.5A PoE Adapter (Included)
Power Method| Passive PoE (Pairs 4, 5+; 7, 8 Return)
Mounting| Pole Mounting Kit Included
Operating Temperature| -30 to 75° C (-22 to 167° F)
Operating Humidity| 5 to 95% Noncondensing
NSM2/NSM3/NSM365 Operating Frequency (MHz)

NSM2| 2412 – 2462
NSM3| 3400 – 3700
NSM365| 3650 – 3675
---|---
NSM5 Operating Frequency (MHz)

Worldwide| 5150 – 5875
EU| 5150 – 5350, 5470 – 5725, 5725 – 5875
USA| U-NII-1| 5150 – 5250
U-NII-2A| 5250 – 5350
U-NII-2C| 5470 – 5725
U-NII-3| 5725 – 5850
CA| 5470 – 5600, 5650 – 5725, 5725 – 5850
NanoStationlocoM2/M5/M9

Dimensions locoM9
locoM2/locoM5|

164 x 72 x 199 mm
(6.46 x 2.83 x 7.83″)
163 x 31 x 80 mm
(6.42 x 1.22 x 3.15″)

Weight locoM9
locoM2/locoM5| 0.9 kg (31.75 oz)

0.18 kg (6.35 oz)

Gain
locoM9/locoM2 locoM5|

8 dBi
13 dBi

Networking Interface| (1) 10/100 Ethernet Port
Max. Power Consumption locoM9
locoM2/locoM5| 6.5W
5.5W
Power Supply| 24V, 0.5A PoE Adapter (Included)
Power Method| Passive PoE (Pairs 4, 5+; 7, 8 Return)
Mounting| Pole Mounting Kit Included
Operating Temperature| -30 to 75° C (-22 to 167° F)
Operating Humidity| 5 to 95% Noncondensing
locoM2 Operating Frequency (MHz)

Worldwide| 2412 – 2462
locoM5 Operating Frequency (MHz)

Worldwide| 5150 – 5875
EU| 5150 – 5350, 5470 – 5725, 5725 – 5875
USA| U-NII-1| 5150 – 5250
---|---|---
U-NII-2A| 5250 – 5350
U-NII-2C| 5470 – 5725
U-NII-3| 5725 – 5850
CA| 5470 – 5600, 5650 – 5725, 5725 – 5850
locoM9 Operating Frequency (MHz)

Worldwide| 902 – 928

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.
    WARNING : Do not use this product in location that can be submerged by water.
    WARNING : Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    e. Protective bonding must be installed in accordance with local national wiring rules and regulations.

Limited Warranty

NanoStationM/locoM Series Quick Start Guide
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.

ISED Canada

CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.

Radiation Exposure Statement

  • This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
  • This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.
  • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

AVIS IMPORTANT

Australia and New Zealand
Warning : This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.

CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.

AT BE BG CY CZ DE DK EE EL ES FI FR HR HU
IE IT LV LT LU MT NL PL PT RO SE SI SK UK

BFWA (Broadband Fixed Wireless Access) members noted in blue

  Note : This device meets Max. TX power limit per ETSI regulations.
Note: This device is restricted to indoor use only when operating in the 5150 – 5350
MHz frequency range within all member states.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
Other countries listed may use the 5.8 GHz frequency band.

WEEE Compliance Statement
Declaration of Conformity
Online Resources

                    UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor -
icon6 © 2022 Ubiquiti Inc. All rights reserved.

Documents / Resources

| UBIQUITI NETWORKS NSM2 Wireless CPE Indoor Outdoor [pdf] User Guide
NSM2 Wireless CPE Indoor Outdoor, NSM2, Wireless CPE Indoor Outdoor, CPE Indoor Outdoor, Indoor Outdoor, Outdoor
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

UBIQUITI NETWORKS User Manuals

Related Manuals