Quick Start Guide
INTRODUCTION
Thank you for purchasing the PAX5400.
This Quick Start Guide is designed to lead you through the installation
process.
PACKAGE CONTENTS
- Access Point
- Mounting options (ceiling, wall, pole, T-rail)
- Closed cable housing lid
- Screws and screw plugs for various surfaces
- Cable ties
CLOUD MANAGEMENT
-
Sign up at console.plasma-cloud.com.
-
Create your first organization by navigating to Organizations → Create new organization.
Fill in the form and click Create. -
You can now create your first network.
Navigate to Networks — Create new network, fill in the form and click Create. -
Setup your network by navigating to Settings → Network.
-
Create and configure your first SSID by navigating to Settings — SSIDs — Create new SSID.
-
Go back to Overview and click on the map to add your first Access Point. The last point can be repeated to add as many Access Points as needed.
You can now plug-in your Access Point and connect it to the Internet. The Plasma Cloud configuration only takes a few seconds!
PHYSICAL INSTALLATION
This Access Point is permitted for indoor use only, and can operate between
0°C ~ 40°C (32°F ~ 104°F).
It comes with a set of mounting options that can be used to install this
device on various surfaces such as: ceilings, walls, poles and T-rails of
various sizes.
This Access Point can be powered by a power adapter or PoE injector.
-
The output shall comply with the requirement of SELV of IEC 60950-1 or ES1 of
IEC 62368-1 and in compliance with the requirements of limited power source of
IEC 60950-1 and IEC 62368-1. Connect dealer or distributor for standard PS. -
All ethernet cables are designed for intra-building connection to other equipment. Do not connect these ports directly to communication wiring or other wiring that exits the building where the appliance is located.
T-RAIL MOUNTING
| Slide the T-rail mount into the slot of the Access Point.
---|---
| Hook the stationary end of the mount bracket to the T-rail.
| Your Access Point is now safely ” to the T-rail.
MOUNTING BRACKET OVERVIEW
WALL MOUNTING
| Use the provided screws and screw plugs to fix the mounting plate on the
wall.
---|---
| Slide the Access Point over the mounting plate until you hear a click sound.
| Your Access Point is now safely attached to the wall.
ANTI-THEFT PROTECTION
The built-in security lock is activated by sliding the Access Point onto the mounting plate until it clicks.
| To unlock, insert a flat screw driver into the notch and push the joint to
the side.
---|---
| The Access Point can now be removed by sliding it off the mounting plate.
© 2024 Plasma Cloud Pte. Ltd. All Rights reserved 10 Anson Road, 33-03
International Plaza, 079903 Singapore www.plasma-cloud.com
The software included in this product contains copyrighted software that is
licensed under GPL. A copy of that license, along with instructions on how to
obtain the source code, is available at
https://www.gnu.org/copyleft/gpl.html
POLE MOUNTING
| Slide the cable ties through the mounting plate and fasten them around the
pole.
---|---
| Slide the Access Point over the mounting plate.
| Your Access Point is now safely tied to the pole.
FCC COMPLIANCE NOTICE
Any changes or modifications not expressly approved by the party responsible
for compliance could void your authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
IC COMPLIANCE NOTICE
This product meets the applicable Innovation, Science and Economic Development
Canada technical specifications.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is
subject to the following two conditions:
- This device may not cause interference; and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This device complies with the ISED radiation exposure limit set forth for an uncontrolled environment. This device should be installed and operated with minimum distance 28 cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
CE / UK COMPLIANCE NOTICE
Hereby, Plasma Cloud declares that the radio equipment type PAX5400 is in compliance with Directive 2014/53/EU and UK Radio Equipment Regulations 2017 SI 2017/1206. The full text of the UK declaration of conformity can be found by scanning the QR code on the right. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.
https://www.plasma-cloud.com/wp-content/uploads/2024/03/Plasma- Cloud-PAX5400-UK-DoC.pdf
| AT| BE| BG| CH| CY| CZ| DE| DK| UK
---|---|---|---|---|---|---|---|---|---
EE| EL| ES| FL| FR| HR| HU| IE|
IS| IT| LI| LT| LU| LV| MT| NL
NO| PL| PT| RO| SE| SI| SK| TR
SUPPORT
For additional technical guidance or to contact our support,
please visit https://support.plasma-cloud.com
PRODUCT PAGE
For more product details, please visit plasma-cloud.com/pax5400
PRIVACY NOTES
For our customer privacy policy, please visit plasma-cloud.com/customer-
policy
References
- Plasma Cloud | Console
- INFORMATION REGARDING THE PROCESSING OF PERSONAL DATA (Customers) | Plasma Cloud
- Plasma Cloud | Cloud Managed Networking Equipment
- The GNU General Public License v3.0 - GNU Project - Free Software Foundation
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>