intelbras SC 5530 Series Switch Campus User Guide Product Information
- January 5, 2024
- intelbras
Table of Contents
- SC 5530 Series Switch Campus
- Product Information
- Specifications
- Product Usage Instructions
- 1. Preparing for Installation
- 2. Safety Recommendations
- Q: Does the product come with additional components?
- Q: Does the product have encryption?
- Q: Does the product process personal data?
- Q: Does Intelbras access or transfer personal data from the
SC 5530 Series Switch Campus
Product Information
Specifications
-
Product Name: Series SC 5530
-
Approval: Anatel approved
-
Data Protection: Follow local laws and regulations
-
Personal Data Processing: Uses and processes personal data
-
Encryption: This product does not have encryption
-
Images: All images in this document are for illustrative
purposes only -
Additional Components: AC power supplies, DC power supplies,
fan modules, and expansion cards are sold separately
Product Usage Instructions
1. Preparing for Installation
This document provides instructions for the installation of the
following Ethernet switches:
Switch Series | Switch Model |
---|---|
SC 5530 switch series | SC 5530-48Y-8H |
SC 5530-24Y-8H
2. Safety Recommendations
To ensure proper usage and avoid equipment damage or bodily
injury, please read and follow the safety recommendations
below:
Examining the Installation Environment
To ensure correct operation of your switch, make sure the
installation environment meets the following requirements:
Item | Requirements |
---|---|
Ventilation and Heat Dissipation | Adequate ventilation to prevent overheating |
Anti-moisture | Avoid water or moisture damage |
Temperature/Humidity | Maintain acceptable ranges for proper operation |
Lightning Protection | Ensure proper grounding |
Cable Routing | Do not run Ethernet cable and power cord in parallel |
ESD Prevention | Follow guidelines for ESD prevention |
Cleanliness | Maintain cleanliness to prevent dust buildup and corrosion |
Corrosive Gas Prevention | Avoid corrosive gases in the installation site |
EMI | Ensure proper EMI protection for cables |
FAQ (Frequently Asked Questions)
Q: Does the product come with additional components?
A: No, AC power supplies, DC power supplies, fan modules, and
expansion cards are sold separately and are not included with the
product.
Q: Does the product have encryption?
A: No, this product does not have encryption.
Q: Does the product process personal data?
A: Yes, this product uses and processes personal data such as
passwords, detailed call records, network addresses, and customer
data records.
Q: Does Intelbras access or transfer personal data from the
product?
A: No, Intelbras does not access, transfer, capture, or carry
out any other type of processing of personal data from this
product, except for data necessary for the operation of the product
itself.
User guide
Series SC 5530
i
This is a product approved by Anatel, the approval number can be found on the
product label. For more information, consult the Anatel website:
https://www.gov.br/anatel/pt-br
Data protection and security Observe local laws regarding the protection and
use of such data and the regulations that prevail in the country. The aim of
data protection legislation is to prevent infringements of individual privacy
rights based on the misuse of personal data.
Processing of personal data This system uses and processes personal data such
as passwords, detailed call records, network addresses and customer data
records, for example.
Guidelines that apply to Intelbras employees » Intelbras employees are subject
to safe trading practices and data confidentiality under the terms of the
company’s work procedures. » It is imperative that the following rules are
observed to ensure that statutory provisions relating to services (be they in-
house services or remote administration and maintenance) are strictly
followed. This preserves the client’s interests and provides additional
personal protection.
Guidelines controlling data processing » Ensure that only authorized persons
have access to customer data. » Use password assignment facilities, without
allowing any exceptions. Never share passwords with unauthorized persons. »
Ensure that no unauthorized person can process (store, change, transmit,
disable or erase) or use customer data. » Prevent unauthorized persons from
gaining access to data media, for example, backup disks or protocol printouts.
» Ensuring that data media that are no longer needed are completely destroyed
and that documents are not stored or left in generally accessible places. »
Working together with the client builds trust.
Misuse and hacking » Access passwords allow access and alteration of any
facility, such as external access to the company’s system to obtain data. of
misuse.
Important: This product does not have encryption. Intelbras does not access,
transfer, capture, or carry out any other type of processing of personal data
from this product, with the exception of data necessary for the operation of
the product itself.
All images in this document are for illustrative purposes only. AC power
supplies, DC power supplies, fan modules, and expansion cards are sold
separately and are not included with the product.
ii
Contents
1 Preparing for
installation·······························································
1-1
Safety recommendations
··········································································································
1-1 Examining the installation environment
························································································
1-1
Cleanliness
·····················································································································
1-3 Corrosive gas limits
··········································································································
1-3 Examining the installation
site····································································································
1-4 Checking power distribution or power supply environment
······························································· 1-5 Laser
safety
···························································································································
1-6 Installation
tools······················································································································
1-6 Installation accessories
············································································································
1-6
2 Installing the switch
····································································· 2-1
Installing the switch in a 19-inch rack
··························································································
2-2 Attaching mounting brackets to the switch
·············································································
2-2 Mounting the switch in the rack
···························································································
2-3
Grounding the switch
···············································································································
2-4 Grounding the switch by using a grounding strip
····································································· 2-4
Verifying the connection after grounding the
switch·································································· 2-5
Installing and removing fan trays
································································································
2-6 Installing a fan tray
···········································································································
2-6 Removing a fan
tray··········································································································
2-7
Installing and removing power
supplies························································································
2-7 Installing a power
supply····································································································
2-8 Removing a power supply
··································································································
2-9
Connecting the power cords
····································································································
2-10 Connecting the power cord for a PSR250-12A/PSR250-12A1 power supply
······························· 2-10 Connecting the power cord for a
PSR450-12D power supply ···················································
2-11
Verifying the
installation··········································································································
2-12
3 Accessing the switch for the first
time·············································· 3-1
Connecting the switch to a configuration
terminal···········································································
3-1 Connecting a DB9-to-RJ45 console
cable··············································································
3-1 Connecting a USB-to-RJ45 console cable
·············································································
3-2
Setting terminal parameters
······································································································
3-3 Starting the
switch···················································································································
3-3
Pre-start
checklist·············································································································
3-3 Powering on the switch
······································································································
3-3
4 Setting up an IRF fabric
······························································· 4-1
IRF fabric setup flowchart
·········································································································
4-1 Planning IRF fabric
setup··········································································································
4-2
Planning IRF fabric size and the installation
site······································································ 4-2
Identifying the master switch and planning IRF member IDs
······················································ 4-2 Planning IRF
topology and
connections·················································································
4-3 Reserving physical IRF ports on the member switches
····························································· 4-4 Planning the
cabling scheme
······························································································
4-4 Configuring basic IRF settings
···································································································
4-6 Connecting the physical IRF ports
······························································································
4-6 Verifying the IRF fabric
setup·····································································································
4-6
5 Maintenance and
troubleshooting··················································· 5-1
Power supply failure
················································································································
5-1 Fan tray failure
·······················································································································
5-1 Configuration terminal display issues
··························································································
5-1
No
display·······················································································································
5-2 Garbled
display················································································································
5-2
iii
1 Preparing for installation
This document is applicable to the following Ethernet switches: Table1-1 Switch series and models
Switch series
SC 5530 switch series
Switch model
SC 5530-48Y-8H SC 5530-24Y-8H
Safety recommendations
To avoid any equipment damage or bodily injury caused by improper use, read
the following safety recommendations before installation. Note that the
recommendations do not cover every possible hazardous condition.
· Before cleaning the switch, remove all power cords from the power supplies.
Do not clean the switch with wet cloth or liquid.
· Do not place the switch near water or in a damp environment. Prevent water
or moisture from entering the switch chassis.
· Do not place the switch on an unstable case or desk. The switch might be
severely damaged in case of a fall.
· Ensure good ventilation of the equipment room and keep the air inlet and
outlet vents of the switch free of obstruction.
· Make sure the power input voltage is as required by the power supply.
· To avoid electrical shocks, do not open the chassis while the switch is
operating or when the switch is just powered off.
· Wear an ESD wrist strap when you replace a removable power supply or fan
tray. Make sure the strap makes good skin contact and is reliably grounded.
Examining the installation environment
To ensure correct operation of your switch, make sure the installation
environment meets the requirements listed in Table1-2.
Table1-2 Checking list for the installation environment
Item
Requirements
Ventilation and heat dissipation
CAUTION:
To ensure correct operation of your device, make sure the installation
environment is adequately ventilated to prevent the switch from overheating.
· Ensure a minimum clearance of 10 cm (3.94 in) around the chassis. · Do not
install the device near a heat source, for example, a stove or
heater. · Ensure air ventilation in the installation environment. · Do not
block the ventilation holes in the device or power adapter.
1-1
Item
Anti-moisture Temperature/humidity
Lightning protection Cable routing
Requirements
CAUTION:
Water or moisture might damage the circuits of the device.
· Do not place the device near water or in a damp environment. · Install the
switch in a clean, dry, and ventilated place where
temperature is controlled in a stable range. · Make sure the installation
environment is free from water leakage or
condensation. If required, install a dehumidification device (such as an air
conditioner with a dehumidification function or a dedicated dehumidifier). ·
Do not operate the device under or near the water source, such as the wash
basin, laundry room, or areas with high humidity. · Do not touch the device
with wet hands.
For correct operation and long service life of your switch, maintain the
temperature and humidity in the equipment room at acceptable ranges.
· Lasting high relative humidity can cause poor insulation, electricity
leakage, mechanical property change of materials, and metal corrosion.
· Lasting low relative humidity can cause washer contraction and ESD and cause
issues including loose mounting screws and circuit failure.
· High temperature can accelerate the aging of insulation materials and
significantly lower the reliability and lifespan of the switch.
For the temperature and humidity requirements of the switch, see technical
specifications in the hardware information and specifications for the switch.
CAUTION:
Ground the switch correctly and verify the grounding. For more information,
see “Grounding the switch.”
· If you ground the switch by using a grounding strip, make sure the grounding
resistance of the grounding strip in the equipment room is less than 1
· If you ground the switch by using a grounding conductor buried in the earth
ground, make sure the grounding resistance of the grounding conductor in the
ground is less than 10.
· Route the signal cables along indoor walls, bury the cables in the earth
ground, or thread the cables through steel tubes. Install a signal lightning
arrester with a nominal discharge current for a corresponding network
interface.
· Keep the signal cables far from power cords and lightning rod down
conductors.
· As a best practice, route power cords indoors. If an AC power cord is routed
from outdoors, connect the AC power cord first to a power lightning arrester
before leading it to the AC power port on the switch. Make sure the power
lightning arrester has a nominal discharge current and the total length of the
power cord from the power lighting arrester to the power port on the switch is
less than 5 m (16.40 ft).
· Ground the switch, rack, independent power supplies, and lightning arresters
separately.
· You must ground optical fibers with reinforcing metal stiffener from
outdoors on an optical distribution frame (ODF) or fiber splice enclosure.
CAUTION:
Do not run an Ethernet cable and power cord in parallel.
1-2
Item
ESD prevention Cleanliness Corrosive gas prevention EMI
Requirements
· Route different types of cables separately. · Keep power cords a minimum of
5 cm (1.97 in) away from other
cables.
· Ground the switch correctly. · To avoid ESD damage to the device or
removable components,
always wear an ESD wrist strap when you install or remove the device or
removable components. · Make sure the wrist strap has good skin contact and is
reliably grounded.
For more information, see “Cleanliness.”
The installation site must be free from corrosive gases such as acid gases and
alkaline gases. For more information, see “Corrosive gas limits.”
· If AC power is used, use a single-phase three-wire power receptacle with
protection earth (PE) to filter interference from the power grid.
· Keep the device far away from radio transmitting stations, radar stations,
and high-frequency devices.
· Use electromagnetic shielding, for example, shielded interface cables, when
necessary.
Cleanliness
Dust buildup on the chassis might cause electrostatic adsorption and dust
corrosion, resulting in poor contact of metal connectors and contact points.
This might shorten the device’s lifetime and even cause device failure in the
worst case. Table1-3 describes the switch requirement for cleanliness.
Table1-3 Switch requirement for cleanliness
Substance
Dust particles
Particle diameter
0.5 µm
Concentration limit
1.8 × 107 particles/m3
To maintain cleanliness in the equipment room, follow these guidelines:
· Keep the equipment room away from pollution sources. Do not smoke, eat, or
drink in the equipment room.
· Use double-layer glass in windows and seal doors and windows with dust-proof
rubber strips. Use screen doors and window screens for doors and windows open
to the outside and make sure the external windows are air tight.
· Use dustproof materials for floors, walls, and ceilings and use wallpaper or
matt paint that does not produce powders.
· Clean the equipment room regularly and clean the air filters of the rack
each month.
· Wear ESD clothing and shoe covers before entering the equipment room, keep
the ESD clothing and shoe covers clean, and change them frequently.
Corrosive gas limits
Corrosive gases can accelerate corrosion and aging of metal components. Make sure the corrosive gases do not exceed the concentration limits as shown in Table1-4.
1-3
Table1-4 Corrosive gas concentration limits
Gas
SO2 H2S Cl2 HCI HF NH3 O3 NOX
Average concentration (mg/m3)
0.3 0.1 0.1 0.1 0.01 1.0 0.05 0.5
Maximum concentration (mg/m3)
1.0 0.5 0.3 0.5 0.03 3.0 0.1 1.0
CAUTION:
As a best practice, control the corrosive gas concentrations in the equipment
room at their average values. Make sure the corrosive gas concentrations do
not exceed 30 minutes per day at their maximum values.
To control corrosive gases, use the following guidelines:
· As a best practice, do not build the equipment room in a place with a high
concentration of corrosive gases.
· Make sure the equipment room is not connected to sewer, vertical shaft, or
septic tank pipelines and keep it far away from these pipelines. The air inlet
of the equipment room must be away from such pollution sources.
· Use environmentally friendly materials to decorate the equipment room. Avoid
using organic materials that contains harmful gases, such as sulfur or
chlorine-containing insulation cottons, rubber mats, sound-proof cottons, and
avoid using plasterboards with high sulfur concentration.
· Place fuel (diesel or gasoline) engines separately. Do not place them in the
same equipment room with the device. Make sure the exhausted air of the
engines will not flow into the equipment room or towards the air inlet of the
air conditioners.
· Place batteries separately. Do not place them in the same room with the
device.
· Employ a professional company to monitor and control corrosive gases in the
equipment room regularly.
Examining the installation site
Before you install the switch, verify that the installation site meets the
installation requirements. The switch can operate correctly in an A1 or A2
installation site. Availability issues might occur if you install the switch
in an A3, B1, B2, or C installation site.
Table1-5 Installation sites
Category
A1: indoor controlled environment
A2: indoor partially controlled
Definition
· Indoor environments where temperature and humidity are controlled.
· Completely enclosed or shielded indoor environments.
· Indoor environments where temperature and humidity are partially
Example
Central equipment rooms, IDC equipment rooms, mobile cabins with air
conditioners, outdoor air conditioner cabinets, and heat exchanger cabinets.
Simple equipment rooms, ordinary houses, garages, corridors, and
1-4
Category
environment
A3: indoor uncontrolled environment
B1: outdoor general environment
B2: harsh environment
C: special environments
Definition
controlled. · Incompletely enclosed or shielded
places. · Places far from pollution sources.
· Indoor environments where temperature and humidity are uncontrolled.
· Incompletely enclosed or shielded places.
· Places near pollution sources.
· Unshielded places where the temperature and humidity are not controlled.
· Places far from pollution sources.
· Unshielded places where the temperature and humidity are not controlled.
· Sea environments or outdoor land environments near pollution sources.
Special application environments
Example
direct ventilation cabinets far from pollution sources, houses without direct
exposure to sunlight or rain, railway station platforms, and stadiums.
Simple equipment rooms, ordinary houses, garages, corridors, and direct
ventilation cabinets near pollution sources, houses without direct exposure to
sunlight or rain, railway station platforms, stadiums, uncleaned rooms after
decoration, and rooms under decoration.
Completely exposed outdoor places far from pollution sources.
Islands, ships, and completely exposed outdoor places near pollution sources.
Buried, underwater, or undersea environments and manholes.
Table1-6 Pollution sources
Category
Radius range
Saline water areas such as oceans and saline lakes
3.7 km (2.30 miles)
Serious pollution sources such as metallurgic plants, coal mines, and heat and power plants
3 km (1.86 miles)
Medium pollution sources such as chemical factories, rubber plants, and electroplating factories
2 km (1.24 miles)
Light pollution sources, such as food factories, tanneries, and heating boilers
1 km (0.62 miles)
Checking power distribution or power supply environment
Table1-7 Requirements for power distribution or power supply environment
Item
Preparation
Voltage
Power receptacle and cables
Requirements
The power supply must be available before you install the switch.
The voltage provided to the switch must be within the operating voltage range.
For the operating voltage range, see technical specifications in the hardware
information and specifications for the switch.
· If the external power supply system provides an AC power outlet, prepare a
country-specific AC power cord yourself. Make sure the PE wire of the AC power
supply is grounded reliably.
1-5
Item
Requirements
· If the external power supply system provides a DC distribution box, prepare
DC power cords yourself.
· Do not use the power cord provided with the switch on other devices.
Laser safety
WARNING!
The switch is Class 1 laser device. Disconnected optical fibers or transceiver
modules might emit invisible laser light. Do not stare into beams or view
directly with optical instruments when the switch is operating.
Installation tools
No installation tools are provided with the switch. Prepare the following
tools yourself as required: · Flathead screwdriver · Phillips screwdriver ·
ESD wrist strap · Marker
Installation accessories
Table1-8 Installation accessories
Part number
2150A0JG
Description
Mounting bracket kit, including a pair of mounting brackets and eight M4
screws
Quantity
1 kit, provided
N/A N/A N/A 26010496
M6 screw Cage nut Grounding cable
Grounding screw 1-6
4, user supplied 4, user provided 1, provided 1, provided
Part number
Description
N/A N/A
04042967 0404A1EE
AC/HVDC power cord DC power cord
DB9-to-RJ45 console cable
USB-to-RJ45 console cable
Quantity
1, provided with PSR250-12A and PSR250-12A1 power supplies 1, provided with
the PSR450-12D power supply
1, optional
1, optional
1-7
2 Installing the switch
CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover
intact, and if you want to open the chassis, contact Intelbras for permission.
Otherwise, Intelbras shall not be liable for any consequence.
Figure2-1 Hardware installation flow
Start
Install the switch
Ground the switch
Install fan trays
Install power supplies
Connect power cords
Verify the installation
Turn on the circuit breakers
Troubleshoot the switch
No Operating correctly?
Yes Install transceiver modules
and connect cables
End
Turn off the circuit breakers
2-1
Installing the switch in a 19-inch rack
IMPORTANT: · M4 screws are used for attaching the mounting brackets to the
chassis. As a best practice, use a
torque of 12 kgf-cm (1.18 Nm) to fasten M4 screws. · M6 screws and cage nuts
are user supplied. As a best practice, use a torque of 30 kgf-cm (2.94
Nm) to fasten M6 screws.
Attaching mounting brackets to the switch
The switch has one mounting position near the network ports and the other
mounting position near the power supplies for the mounting brackets. Select
one position as needed. To attach the mounting brackets to the chassis: 1.
Place the wide flange of the mounting bracket against the chassis side panel.
Align the
mounting bracket installation holes with the screw holes in the chassis. To
install the mounting brackets at the port-side mounting position, see
Figure2-2. To install the mounting brackets at the power supply-side mounting
position, see Figure2-3. 2. Fasten the M4 screws to secure the mounting
bracket to the switch. 3. Attach the other mounting bracket to the other side
of the chassis in the same way. Figure2-2 Attaching the mounting brackets to
the port-side mounting position
2-2
Figure2-3 Attaching the mounting brackets to the power supply-side mounting
position
Mounting the switch in the rack
1. Wear an ESD wrist strap and make sure it makes good skin contact and is
reliably grounded. 2. Verify that the mounting brackets have been securely
attached to the switch chassis. 3. Attach cage nuts to the front rack posts.
4. One person supports the bottom of the switch, and moves the switch to an
appropriate position
based on the installation positions of the mounting brackets. 5. Another
person uses user supplied M6 screws and cage nuts to attach the mounting
brackets
to the rack and verifies that the brackets are level and secure. Figure2-4
Mounting the switch in the rack
2-3
Grounding the switch
WARNING! · Correctly connecting the grounding cable is crucial to lightning,
ESD, and EMI protections. Make
sure you connect the grounding cable correctly for the switch. · For
information about how to protect your switch from lightning strikes, see
Intelbras Network
Devices Lightning Protection Guide.
To protect against the following types of issues, use a grounding cable to
connect the switch to the earthing facility at the installation site: · Bodily
injury from electric shocks. · Device and power and data line damages. ·
Electrical fires, lightning strokes, electromagnetic coupling interferences,
and ESD damages. Select a grounding method based on the installation
environment.
NOTE: The positions of power supplies and grounding terminals in this section
are for illustration only.
Grounding the switch by using a grounding strip
CAUTION: · Connect the grounding cable to the grounding system in the
equipment room. Do not connect it
to a fire main or lightning rod. · To guarantee the grounding effect and avoid
switch damage, use the grounding cable provided
with the switch to connect the switch to a grounding strip in the equipment
room.
Connecting the grounding cable to the chassis IMPORTANT: As a best practice,
use a torque of 12 kgf-cm (1.18 Nm) to fasten the grounding screw.
To connect the grounding cable to the chassis: 1. Remove the grounding screw
from the grounding hole in the chassis.
The grounding screw and grounding hole are on the rear panel of the chassis
and a grounding sign is provided. 2. Attach the grounding screw to the ring
terminal of the grounding cable. 3. Use a screwdriver to fasten the grounding
screw into the grounding hole.
IMPORTANT: Orient the grounding cable as shown in Figure2-5 so that you can
easily install or remove the fan trays.
2-4
Figure2-5 Connecting the grounding cable to the chassis
(1) Ring terminal (3) Grounding hole (5) Grounding cable
(2) Grounding sign (4) Grounding screw
Connecting the grounding cable to a grounding strip
1. Remove the hex nut of a grounding post on the grounding strip. 2. Attach
the ring terminal of the grounding cable to the grounding post and use the hex
nut to
secure the ring terminal to the post.
Figure2-6 Connecting the grounding cable to a grounding strip
(1) Grounding post (3) Grounding cable
(2) Grounding strip (4) Hex nut
Verifying the connection after grounding the switch
1. Use a multimeter to measure the resistance between the switch grounding
terminal and grounding point, and make sure the resistance is less than 0.1
2. Use a grounding resistance tester to measure the grounding resistance of
the grounding strip, and make sure the grounding resistance is less than 1
For information about resistance measurement, see Intelbras Network Devices
Lightning Protection Guide.
2-5
Installing and removing fan trays
CAUTION: · You can power on the switch only when the switch is installed with
five fan trays of the same
model. · If more than one fan tray fails during switch operation, do not
remove the failed fan trays
simultaneously. Replace the fan trays one by one and finish replacing each fan
tray within three minutes. The switch can be delivered with removable fan
trays installed on it. Contact the Intelbras marketing personnel if you want
the switch to be delivered with the ordered fan trays installed on it. The
switch came with empty fan tray slots. Choose fan tray models for the switch
based on the heat dissipation requirements. · The LSPM1FANSA-SN fan tray
provides power supply side-intake and port side-exhaust
airflow. Its handle is blue. · The LSPM1FANSB-SN fan tray provides port side-
intake and power supply side-exhaust
airflow. Its handle is red.
Installing a fan tray
CAUTION: To prevent damage to the fan tray or the connectors on the backplane,
insert the fan tray gently. If you encounter a hard resistance while inserting
the fan tray, pull out the fan tray and insert it again. To install a fan
tray: 1. Wear an ESD wrist strap and make sure it makes good skin contact and
is reliably grounded. 2. Unpack the fan tray and verify that the fan tray
model is correct. 3. Grasp the two handles of the fan tray with the side
marked TOP facing up, and slide the fan tray
along the guide rails into the slot until the fan tray seats in the slot and
has a firm contact with the backplane. Figure2-7 Installing a fan tray
2-6
Removing a fan tray
WARNING! · Do not touch any bare wires or terminals on the fan tray. · Do not
place a fan tray in a moist location or let liquid flow into it. · Contact
Intelbras Support if the circuits or components on a fan tray are faulty. Do
not remove
any fan tray components.
To remove a fan tray: 1. Wear an ESD wrist strap and make sure it makes good
skin contact and is reliably grounded. 2. Grasp the two handles of the fan
tray, as shown by callout 1 in Figure2-8, and pull out the fan
tray slowly along the guide rails. 3. Put the removed fan tray in an
antistatic bag. Figure2-8 Removing a fan tray
Installing and removing power supplies
The switch can be delivered with removable power supplies installed on it. Contact the Intelbras marketing personnel if you want the switch to be delivered with the ordered power supplies installed on it.
WARNING!
· To avoid bodily injury or switch damage, strictly follow the procedures in
Figure2-9 and Figure2-10 to install and remove a power supply.
· You must provide a circuit breaker for each power supply.
CAUTION: To use two power supplies for the switch, make sure they are the same model.
Figure2-9 Installation procedure
Install thepowersupply
Connect th e power cord
Turnbornetahkeercircuit
2-7
Figure2-10 Removal procedure
Turnborffetahkeercircuit
Remove th e power cord
Removseupthpelypower
Installing a power supply
The installation procedure is the same for the PSR250-12A, PSR250-12A1, and
PSR450-12D power supplies. The following procedure installs a PSR250-12A1
power supply. To install a PSR250-12A1 power supply: 1. Wear an ESD wrist
strap. Make sure the strap makes good skin contact and is reliably
grounded. 2. Remove the filler panel, if any, from the target power supply
slot.
Figure2-11 Removing the filler panel from the target power supply slot
3. Unpack the power supply. Make sure the power supply model is as required.
Keep the packaging box and packaging bag for the power supply secure for
future use.
4. Correctly orient the power supply. Make sure the lettering on the power
supply is upward. 5. Grasping the handle of the power supply with one hand and
supporting its bottom with the
other, slide the power supply slowly into the slot along the guide rails until
the latch of the power supply clicks into place. To prevent damage to the
power supply or the connectors on the backplane, insert the power supply
gently. If you encounter a hard resistance when inserting the power supply,
pull out the power supply and insert it again.
2-8
Figure2-12 Installing a power supply
Removing a power supply
1. Wear an ESD wrist strap and make sure it makes good skin contact and is
reliably grounded. 2. Disconnect the power cord. 3. Grasping the handle of the
power supply with one hand with the thumb pressing the latch
towards the handle direction, pull the power supply part way out of the slot.
Then supporting the power supply bottom with the other, pull the power supply
slowly out of the slot. 4. Place the removed power supply on an antistatic mat
or its packaging bag for future use. 5. If you are not to install a new power
supply after removing the old one, install a filler panel in the slot in time.
Figure2-13 Removing a power supply
2-9
Connecting the power cords
CAUTION:
Provide a circuit breaker for each power input and make sure the circuit
breaker is off before connecting the power cord.
Table2-1 Power cord connection procedures at a glance
Power supply model
Available power source
Connection procedure reference
PSR250-12A PSR250-12A1
PSR450-12D
AC power source
48 VDC power source in the equipment room RPS1600-A
Connecting the power cord for a PSR250-12A/PSR250-12A1 power supply
Connecting the power cord for a PSR450-12D power supply
Connecting the power cord for a PSR250-12A/PSR250-12A1 power supply
The power cord connection procedure is the same for the PSR250-12A and
PSR250-12A1 power supplies. The following uses a PSR250-12A1 as an example.
To connect the power cord: 1. Wear an ESD wrist strap. Make sure the strap
makes good skin contact and is reliably
grounded. 2. Plug the female connector of the power cord into the power
receptacle on the power supply, as
shown by callout 1 in Figure2-14. 3. Use a releasable cable tie to secure the
power cord to the handle of the power supply, as shown
by callout 2 in Figure2-14. 4. Connect the other end of the power cord to an
AC power source.
Figure2-14 Connecting the power cord for a PSR250-12A1 power supply (1)
2-10
Figure2-15 Connecting the power cord for a PSR250-12A1 power supply (2)
Connecting the power cord for a PSR450-12D power supply
CAUTION: · To use a 48 VDC power source in the equipment room to supply power
to the power supply, use
the DC power cord supplied with the power supply. When connecting the DC power
cord, identify the positive (+) and negative (-) marks on the two wires to
avoid connection mistakes. · To use an Intelbras RPS to supply power to the
power supply, use a compatible RPS power cord to connect the RPS to the power
supply. To connect the power cord for a PSR450-12D power supply: 1. Wear an
ESD wrist strap and make sure it makes good skin contact and is reliably
grounded. 2. Use a flathead screwdriver to loosen the screws on the protection
cover over the DC power
receptacle on the power supply and then remove the protection cover (see
callouts 1 and 2 in Figure2-16). 3. Correctly orient the power cord plug, and
then insert the plug into the power receptacle (see callout 3 in Figure2-17).
If you orient the plug upside down, you cannot insert it into the power
receptacle. 4. Use a flathead screwdriver to fasten the screws on the plug to
secure the plug in the power receptacle (see callout 4 in Figure2-17). 5.
Connect the other end of the power cord to a 48 VDC power source or an RPS.
2-11
Figure2-16 Connecting the power cord for a PSR450-12D power supply (1)
Figure2-17 Connecting the power cord for a PSR450-12D power supply (2)
Verifying the installation
Before powering on the switch, verify the following items: · There is enough
space around the switch for heat dissipation. · The rack on which the switch
is mounted is stable. · The grounding cable is securely connected. · The power
source specifications are as required by the device. · The power input cables
are correctly connected. · If part of the network cable for a port is routed
outdoors, verify that a network port lightning
protector is used for the port. · If a power line is routed from outdoors,
verify that a surge protected power strip is used for the
switch.
2-12
3 Accessing the switch for the first time
Connecting the switch to a configuration terminal
As shown in Figure3-1, you can access the switch by connecting the serial
console port on the switch to a configuration terminal. Figure3-1 Connecting
the switch to a configuration terminal
As shown in Table3-1, two types of console cables can be used for connecting
the switch to a configuration terminal.
Table3-1 Connection methods and console cables
Connection method Console cable type
Using the serial console port for connection
DB9-to-RJ45 console cable
USB-to-RJ45 console cable
Configuration terminal-side connector
DB-9 female connector
USB connector
Switch-side connector
RJ-45 connector
RJ-45 connector
The RJ-45 signal pinout varies by the vendor of the cable. To avoid abnormal
display on the configuration terminal, use a console cable provided by
Intelbras (as shown in Table1-8).. To prepare a serial console cable yourself,
make sure the RJ-45 connector signal pinout is as shown in Table3-2.
Connecting a DB9-to-RJ45 console cable
CAUTION:
Follow these guidelines when you connect a DB9-to-RJ45 console cable:
· Identify the mark on the serial console port and make sure you are
connecting to the correct port.
· The serial ports on PCs do not support hot swapping. To connect a PC to an
operating switch, first connect the PC end. To disconnect a PC from an
operating switch, first disconnect the switch end.
3-1
A DB9-to-RJ45 console cable is an 8-core shielded cable, with a crimped RJ-45
connector at one end for connecting to the serial console port of the switch,
and a DB-9 female connector at the other end for connecting to the serial port
on the console terminal.
Figure3-2 DB9-to-RJ45 console cable
A side Pin 9
Main label
8
B side
A
B
1
Pin 1
Table3-2 Serial console cable signal pinout
RJ-45
1 2 3 4 5 6 7 8
Signal
RTS DTR TXD SG SG RXD DSR CTS
DB-9
8 6 2 5 5 3 4 7
Signal
CTS DSR RXD SG SG TXD DTR RTS
To connect the switch to a configuration terminal (for example, a PC) through
a DB9-to-RJ45 console cable:
1. Plug the DB-9 female connector of the DB9-to-RJ45 console cable to the
serial port on the PC.
2. Connect the RJ-45 connector to the serial console port on the switch.
Connecting a USB-to-RJ45 console cable
IMPORTANT: · To use a USB-to-RJ45 console cable to connect the switch to a
configuration terminal, first
download and install the USB-to-RJ45 console driver on the configuration
terminal and then connect the USB-to-RJ45 console cable to the configuration
terminal. · If you have connected a USB-to-RJ45 console cable to the
configuration terminal before driver installation, you must remove and
reconnect the USB-to-RJ45 console cable to the configuration terminal.
NOTE: For the RJ-45 connector signal pinout of the USB-to-RJ45 console cable,
see Table3-2.
The following installs the driver on the Windows system. To install the driver
on other operating systems, see the installation guide in the driver
compression package named by the corresponding operating system.
3-2
To connect the switch to the configuration terminal through a USB-to-RJ45
console cable:
Setting terminal parameters
To configure and manage the switch through the console port, you must run a
terminal emulator program, such as TeraTermPro, on your configuration
terminal. You can use the emulator program to connect a network device, a
Telnet site, or an SSH site. For more information about the terminal emulator
programs, see the user guides for these programs. Configure the terminal
parameters as follows: · Bits per second–9,600. · Data bits–8. · Parity–None.
· Stop bits–1. · Flow control–None.
Starting the switch
Pre-start checklist
Before powering on the switch, verify the following items: · The power cord is
correctly connected. · The input power voltage is as required by the switch. ·
The console cable is correctly connected. · The PC has started, and the
terminal parameters have been correctly configured.
Powering on the switch
During the startup process, you can access Boot ROM menus to perform tasks
such as software upgrade and file management. The Boot ROM interface and menu
options differ with software versions. For more information about Boot ROM
menu options, see the software-matching release notes for the device. After
the startup process is completed, you can access the CLI to configure the
switch. For more information about the configuration commands, see the
configuration guides and command references for the switch.
3-3
4 Setting up an IRF fabric (Stacking)
You can use Intelbras IRF technology to connect and virtualize multiple SC
5530 switches into a large virtual switch called an “IRF fabric” for flattened
network topology, and high availability, scalability, and manageability.
A SC 5530 switch can form an IRF fabric only with switches in the same series
All IRF member devices must run the same software image version. Make sure the
software auto-update feature is enabled on all member devices.
IRF fabric setup flowchart
Figure4-1 IRF fabric setup flowchart
Start
Plan IRF fabric setup
Install IRF member switches
Connect the grounding cable and power cords
Power on the switches
Configure basic IRF settings
Connect the physical IRF ports
Standby switches reboot and the IRF fabric is automatically
established
End
To set up an IRF fabric: Step
1. Plan IRF fabric setup
Description
Plan the installation site and IRF fabric setup parameters:
4-1
Step
2. Install IRF member switches 3. Connect grounding cables and
power cords 4. Power on the switches 5. Configure basic IRF settings
6. Connect the physical IRF ports
Description
· Planning IRF fabric size and the installation site · Identifying the master
switch and planning IRF member IDs · Planning IRF topology and connections ·
Reserving physical IRF ports on the member switches · Planning the cabling
scheme
See “Installing the switch in a 19-inch rack.”
See “Grounding the switch” and “Connecting the power cord.”
N/A
See IRF Configuration Guide for the switch series.
Connect IRF member switches. Use QSFP+/QSFP28 transceiver modules and optical
fibers for long distance connection. Use QSFP+/QSFP28 copper cables for short
distance connection. All switches except the master switch automatically
reboot, and the IRF fabric is established.
Planning IRF fabric setup
This section describes issues that an IRF fabric setup plan must cover.
Planning IRF fabric size and the installation site
Choose switch models and identify the number of required IRF member switches,
depending on the user density and upstream bandwidth requirements. The
switching capacity of an IRF fabric equals the total switching capacities of
all member switches. Plan the installation site depending on your network
solution, as follows: · Place all IRF member switches in one rack for
centralized high-density access. · Distribute the IRF member switches in
different racks to implement the ToR access solution for
a data center.
Identifying the master switch and planning IRF member IDs
Determine which switch you want to use as the master for managing all member
switches in the IRF fabric. An IRF fabric has only one master switch. You
configure and manage all member switches in the IRF fabric at the CLI of the
master switch. IRF member switches automatically elect a master. You can
affect the election result by assigning a high member priority to the intended
master switch. For more information about master election, see the
configuration guides and command references for the switch. Prepare an IRF
member ID assignment scheme. An IRF fabric uses member IDs to uniquely
identify and manage its members, and you must assign each IRF member switch a
unique member ID.
4-2
Planning IRF topology and connections
You can create an IRF fabric in daisy chain topology or more reliable ring
topology. In ring topology, the failure of one IRF link does not cause the IRF
fabric to split as in daisy chain topology. Instead, the IRF fabric changes to
a daisy chain topology without interrupting network services.
You connect the IRF member switches through IRF ports, the logical interfaces
for the connections between IRF member switches. Each IRF member switch has
two IRF ports: IRF-port 1 and IRF-port 2. To use an IRF port, you must bind a
minimum of one physical port to it.
When connecting two neighboring IRF member switches, you must connect the
physical ports of IRF-port 1 on one switch to the physical ports of IRF-port 2
on the other switch. The QSFP28 ports on the switch can provide 40GE/100GE IRF
connection. You can bind several IRF physical ports to an IRF port for
increased bandwidth and availability.
Figure4-2 and Figure4-3 show the topologies of an IRF fabric. The IRF port
connections in the two figures are for illustration only, and more connection
methods are available.
Figure4-2 IRF fabric in daisy chain topology
1
2
3
IRF-port1 1
IRF-port2 2
IRF-port1
IRF-port2 3
4-3
Figure4-3 IRF fabric in ring topology
1
2
3
IRF-port1
IRF-port2
1
IRF-port2 IRF-port1
2
IRF-port1 IRF-port2
3
Reserving physical IRF ports on the member switches
Reserve the physical IRF ports on the member switches according to your
topology and connection scheme. QSFP28 ports on the switch can be used for IRF
connection. 25-GE/10-GE breakout interfaces split from a QSFP28 port cannot be
used for IRF connection.
IMPORTANT: · All physical ports to be bound to an IRF logical interface must
have the same data rate. · QSFP28 ports on the switch operate at 40 Gbps by
default. Licenses are available for you to
increase the QSFP28 port speed to 100 Gbps.
Planning the cabling scheme
You can use QSFP+/QSFP28 transceiver modules and optical fibers or
QSFP+/QSFP28 copper cables for IRF connection: · For a short-distance IRF
connection in an equipment room, use a QSFP+/QSFP28 cable. · For a long-
distance IRF connection, use QSFP+/QSFP28 transceiver modules and optical
fibers. The following subsections describe several Intelbras recommended IRF
connection schemes. All these schemes use a ring topology. The ring topology
is not applicable to IRF setup with two devices.
4-4
IMPORTANT: In these schemes, all physical IRF ports are located on the same
side. If physical IRF ports are on different sides, you must measure the
distance between them to select an appropriate cable. Connecting the IRF
member switches in one rack Connect the IRF member switches (4 switches in
this example) in a rack as shown in Figure4-4. The switches in the ring
topology (see Figure4-5) are in the same order as connected in the rack.
Figure4-4 Connecting the switches in one rack
1
2
3
4
Figure4-5 IRF fabric topology
1
IRF-port2
IRF-port1
IRF-port2
2 IRF-port1
IRF-port1
IRF-port2
4
IRF-port2
IRF-port1 3
Connecting the IRF member switches in a ToR solution
You can install IRF member switches (4 switches in this example) in different
racks side by side to deploy a top of rack (ToR) solution as shown in
Figure4-6. Use QSFP+/QSFP28 transceiver modules and optical fibers for
connection if a large distance exists between the member switches.
4-5
Figure4-6 ToR cabling
1
2
3
4
Configuring basic IRF settings
After you install the IRF member switches, power on the switches, and log in
to each IRF member switch to configure their member IDs, member priorities,
and IRF port bindings. For information about accessing the switch, see
Fundamentals Configuration Guide for the switch. For more information about
configuring basic IRF settings, see IRF Configuration Guide for the switch.
Connecting the physical IRF ports
Connect the IRF member switches as planned. Wear an ESD wrist strap when you
connect cables or transceiver modules and fibers. For information about how to
connect them, see Intelbras Transceiver Modules and Network Cables
Installation Guide.
Verifying the IRF fabric setup
To verify the basic functionality of the IRF fabric after you finish
configuring basic IRF settings and connecting IRF ports: 1. Log in to the IRF
fabric through the console port of any member switch.
2. Create a Layer 3 interface, assign it an IP address, and make sure the IRF
fabric and the remote network management station can reach each other.
3. Use Telnet, web, or SNMP to access the IRF fabric from the network
management station. (See Fundamentals Configuration Guide for the switch.)
4. Verify that you can manage all member switches as if they were one node.
5. Display the running status of the IRF fabric by using the commands in
Table4-1.
Table4-1 Displaying and maintaining IRF configuration and running status
Task
Display information about the IRF fabric. Display all members’ IRF
configurations that take effect at a reboot. Display IRF fabric topology
information.
Command display irf display irf configuration display irf topology
4-6
NOTE: To avoid IP address collision and network problems, configure a minimum
of one multi-active detection (MAD) mechanism to detect the presence of
multiple identical IRF fabrics and handle collisions. For more information
about MAD detection, see IRF Configuration Guide for the switch.
4-7
5 Maintenance and troubleshooting
Power supply failure
The switch uses removable power supplies. You can determine whether a power
supply is faulty by observing the status LED on the power supply. Symptom The
status LED on the power supply is not steady green, which indicates that the
power supply is faulty. Solution To resolve the issue: 1. Verify that the
power supply model is as required by the switch. 2. Verify that the power
supply is securely installed in the switch. 3. Verify that the operating
temperature of the switch is in an acceptable range and the power
supply has good ventilation. 4. If the issue persists, contact Intelbras
Support. To replace a power supply, see “Installing and removing power
supplies.”
Fan tray failure
CAUTION: If more than one fan tray fails during the switch operation, do not
remove the failed fan trays simultaneously. Replace the fan trays one by one
and finish replacing each fan tray within 3 minutes.
CAUTION: If more than one fan tray fails during the switch operation, do not
remove the failed fan trays simultaneously. Replace the fan trays one by one
and finish replacing each fan tray within 3 minutes.
The switch uses removable fan trays. You can determine whether a fan tray is
faulty by observing the status LED on the fan tray. Symptom The status LED on
a fan tray indicates that the fan tray is faulty.. Solution Replace the fan
tray. For information about how to replace the fan tray, see “Installing and
removing fan tray.”
Configuration terminal display issues
If the configuration environment setup is correct, the configuration terminal
displays booting information when the switch is powered on. If the setup is
incorrect, the configuration terminal displays nothing or garbled text.
5-1
No display
Symptom The configuration terminal does not have display when the switch is
powered on.
Solution To resolve the issue: 1. Verify that the power supply is supplying
power to the switch correctly. 2. Verify that the console cable is correctly
connected. 3. Verify that the console cable does not have any issues and the
terminal settings are correct. 4. If the issue persists, contact Intelbras
Support.
Garbled display
Symptom The display on the configuration terminal is garbled.
Solution To resolve the issue: 1. Verify that the following settings are
configured for the terminal: Baud rate–9,600. Data bits–8. Stop bits–1.
Parity–None. Flow control–None. 2. If the issue persists, contact Intelbras
Support.
5-2
Warranty term
It is expressly stated that this contractual guarantee is granted subject to
the following conditions: 1. All parts, pieces and components of the product
are guaranteed against any manufacturing defects that may occur, for a period
of 3 (three) years 3 (three) months of legal warranty and 33 (thirty-three)
months months of contractual warranty -, counted from the date of delivery of
the product to the Consumer, as stated on the product purchase invoice, which
is an integral part of this Term throughout the national territory. This
contractual warranty includes the free exchange of parts, pieces and
components that present manufacturing defects, including the labor used in
this repair. If no manufacturing defect is found, but rather defect(s) arising
from inappropriate use, the Consumer will bear these expenses. 2. Installation
of the product must be carried out in accordance with the Product Manual
and/or Installation Guide. If your product requires installation and
configuration by a qualified technician, look for a suitable and specialized
professional, as the costs of these services are not included in the value of
the product. 3. In the event that the Consumer requests home assistance, he or
she must go to the nearest Authorized Service to consult the technical visit
fee. If it is found necessary to remove the product, the costs resulting from
transport and security to and from the product are the responsibility of the
Consumer. 4. In the event that the Consumer requests home assistance, he or
she must go to the nearest Authorized Service to consult the technical visit
fee. If it is found necessary to remove the product, the resulting expenses,
such as transport and security to and from the product, are the responsibility
of the Consumer. 5. The guarantee will completely lose its validity in the
occurrence of any of the following hypotheses: a) if the defect is not
manufacturing, but caused by the Consumer or by third parties outside the
manufacturer; b) if damage to the product arises from accidents, accidents,
acts of nature (lightning, floods, landslides, etc.), humidity, voltage in the
electrical network (overvoltage caused by accidents or excessive fluctuations
in the network), installation/use in disagreement with the user manual or
resulting from natural wear and tear of parts, pieces and components; c) if
the product has been influenced by a chemical, electromagnetic, electrical or
animal nature (insects, etc.); d) if the product’s serial number has been
tampered with or erased; e) if the equipment has been tampered with. 6. This
warranty does not cover loss of data, therefore, it is recommended, if
applicable to the product, that the Consumer makes a regular backup copy of
the data contained in the product. 7. Intelbras is not responsible for the
installation of this product, nor for any attempts at fraud and/or sabotage in
its products. Keep the software and applications used up to date, if
applicable, as well as the necessary network protections to protect against
intrusions (hackers). The equipment is guaranteed against defects within its
normal conditions of use, and it is important to be aware that, as it is
electronic equipment, it is not free from fraud and scams that could interfere
with its correct functioning. The contractual guarantee of this term is
complementary to the legal one, therefore, Intelbras S/A reserves the right to
change the general, technical and aesthetic characteristics of its products
without prior notice. These being the conditions of this complementary
Warranty Term, Intelbras S/A reserves the right to change the general,
technical and aesthetic characteristics of its products without prior notice.
5-3
Termo de garantia
Fica expresso que esta garantia contratual é conferida mediante as seguintes
condições: 1. Todas as partes, peças e componentes do produto são garantidos
contra eventuais defeitos de fabricação, que porventura venham a apresentar,
pelo prazo de 3 (três) anos sendo 3 (três) meses de garantia legal e 33
(trinta e três) meses de garantia contratual , contado a partir da data de
entrega do produto ao Senhor Consumidor, conforme consta na nota fiscal de
compra do produto, que é parte integrante deste Termo em todo o território
nacional. Esta garantia contratual compreende a troca gratuita de partes,
peças e componentes que apresentarem defeito de fabricação, incluindo a mão de
obra utilizada nesse reparo. Caso não seja constatado defeito de fabricação, e
sim defeito(s) proveniente(s) de uso inadequado, o Senhor Consumidor arcará
com essas despesas. 2. A instalação do produto deve ser feita de acordo com o
Manual do Produto e/ou Guia de Instalação. Caso seu produto necessite a
instalação e configuração por um técnico capacitado, procure um profissional
idôneo e especializado, sendo que os custos desses serviços não estão inclusos
no valor do produto. 3. Na eventualidade de o Senhor Consumidor solicitar
atendimento domiciliar, deverá encaminhar-se ao Serviço Autorizado mais
próximo para consulta da taxa de visita técnica. Caso seja constatada a
necessidade da retirada do produto, as despesas decorrentes de transporte e
segurança de ida e volta do produto ficam sob a responsabilidade do Senhor
Consumidor. 4. Na eventualidade de o Senhor Consumidor solicitar atendimento
domiciliar, deverá encaminhar-se ao Serviço Autorizado mais próximo para
consulta da taxa de visita técnica. Caso seja constatada a necessidade da
retirada do produto, as despesas decorrentes, como as de transporte e
segurança de ida e volta do produto, ficam sob a responsabilidade do Senhor
Consumidor. 5. A garantia perderá totalmente sua validade na ocorrência de
quaisquer das hipóteses a seguir: a) se o vício não for de fabricação, mas sim
causado pelo Senhor Consumidor ou por terceiros estranhos ao fabricante; b) se
os danos ao produto forem oriundos de acidentes, sinistros, agentes da
natureza (raios, inundações, desabamentos, etc.), umidade, tensão na rede
elétrica (sobretensão provocada por acidentes ou flutuações excessivas na
rede), instalação/uso em desacordo com o manual do usuário ou decorrentes do
desgaste natural das partes, peças e componentes; c) se o produto tiver
sofrido influência de natureza química, eletromagnética, elétrica ou animal
(insetos, etc.); d) se o número de série do produto tiver sido adulterado ou
rasurado; e) se o equipamento tiver sido violado. 6. Esta garantia não cobre
perda de dados, portanto, recomenda-se, se for o caso do produto, que o
Consumidor faça uma cópia de segurança regularmente dos dados que constam no
produto. 7. A Intelbras não se responsabiliza pela instalação deste produto, e
também por eventuais tentativas de fraudes e/ou sabotagens em seus produtos.
Mantenha as atualizações do software e aplicativos utilizados em dia, se for o
caso, assim como as proteções de rede necessárias para proteção contra
invasões (hackers). O equipamento é garantido contra vícios dentro das suas
condições normais de uso, sendo importante que se tenha ciência de que, por
ser um equipamento eletrônico, não está livre de fraudes e burlas que possam
interferir no seu correto funcionamento. A garantia contratual deste termo é
complementar à legal, portanto, a Intelbras S/A reserva-se o direito de
alterar as características gerais, técnicas e estéticas de seus produtos sem
aviso prévio. Sendo estas as condições deste Termo de Garantia complementar, a
Intelbras S/A se reserva o direito de alterar as características gerais,
técnicas e estéticas de seus produtos sem aviso prévio.
5-4