BOSCH Quigo Plus Cross Line Laser with Tripod Instruction Manual
- June 9, 2024
- Bosch
Table of Contents
Quigo
Original instructions
Safety Instructions
All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool unrecognisable. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.
-
Warning! If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.
-
The measuring tool is delivered with a laser warning sign (marked in the illustration of the measuring tool on the graphics page).
-
If the text of the laser warning label is not in your national language, stick the provided warning label in your national language over it before operating for the first time.
Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes. -
If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.
-
Do not make any modifications to the laser equipment.
-
Do not use the laser goggles (accessory) as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
-
Do not use the laser goggles (accessory) as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colours.
-
Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.
-
Do not let children use the laser measuring tool unsupervised. They could unintentionally blind themselves or other persons.
-
Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.
Keep the magnet away from implants and other medical devices, e.g. pacemakers or insulin pumps. The magnet generates a field that can impair the function of implants and medical devices. -
Keep the measuring tool away from magnetic storage media and magnetically-sensitive devices. The effect of the magnets can lead to irreversible data loss.
Product Description and Specifications
Please observe the illustrations at the beginning of this operating manual.
Intended Use
The measuring tool is intended for determining and checking horizontal and
vertical lines.
The measuring tool is suitable for indoor use.
This product is a consumer laser product in accordance with EN 50689.
Product features
The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.
(1) 1/4″ mount of the adapter plate
(2) Fine adjustment screw of the adapter plate
(3) Adapter plate
(4) On/off switch
(5) Laser beam outlet aperture
(6) 1/4″ tripod mount
(7) Battery compartment cover
(8) Laser warning label
(9) Serial number
(10) Locking mechanism of the battery compartment cover
(11) Tripoda)
(12) Laser viewing glassesa)
(13) 1/4″ screw of the holder
(14) Locking screw of the holder
(15) Fastening screw of the holder
(16) Holder
a) Accessories shown or described are not included with the product as standard. You can find the complete selection of accessories in our accessories range.
Technical data
Cross line laser|
Quigo
---|---
Article number|
3 603 F63 5..
Working range at leastA)|
10 m
Levelling accuracyB)C)|
±0.8 mm/m
Self-levelling range|
±4°
Levelling time|
6 s
Operating temperature|
+5 °C to +40 °C
Storage temperature|
–20 °C to +70 °C
Max. altitude|
2000 m
Relative air humidity max.|
90 %
Pollution degree according to IEC 61010-1|
2D)
Laser class|
2
Laser type|
< 1 mW, 630−650 nm
C₆|
1
Divergence|
0.5 mrad (full angle)
Tripod mount|
1/4″
Batteries|
2 × 1.5 V LR3 (AAA)
Operating time, approx.B)|
5 h
Weight according to EPTA-Procedure 01:2014|
– Cross line laser|
0.27 kg
– Holder|
0.20 k
Dimensions (length × width × height)|
65 × 65 × 65 mm
A) The working range may be reduced by unfavourable environmental conditions
(e.g. direct sunlight).
B) At 20-25 °C
C) The values stated presuppose normal to favourable environmental conditions
(e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme
fluctuations in temperature can cause deviations in accuracy.
D) Only non-conductive deposits occur, whereby occasional temporary
conductivity caused by condensation is expected.
The serial number (9) on the type plate is used to clearly identify your measuring tool.
Assembly
Inserting/changing the batteries
It is recommended that you use alkaline manganese batteries to operate the
measuring tool.
Push the locking mechanism (10) in the direction of the arrow to open the
battery compartment cover (7) and remove the battery compartment cover.
Insert the batteries supplied.
When inserting the batteries, ensure that the polarity is correct according to
the illustration on the inside of the battery compartment.
If the batteries become weak, the laser lines will flash quickly for a few
seconds.
Always replace all the batteries at the same time. Only use batteries from the
same manufacturer and which have the same capacity.
- Take the batteries out of the measuring tool when you are not using it for a prolonged period of time. The batteries can corrode and self-discharge during prolonged storage in the measuring tool.
Operation
Starting Operation
- Protect the measuring tool from moisture and direct sunlight.
- Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
- Avoid substantial knocks to the measuring tool and avoid dropping it. Damaging the measuring tool can cause accuracy to be compromised. If the laser line is subjected to a substantial knock or is dropped, check it by comparing it to a known horizontal or vertical reference line.
- Switch the measuring tool off when transporting it. The pendulum unit is locked when the tool is switched off, as it can otherwise be damaged by big movements.
Switching on/off
To switch on the measuring tool, push the on/off switch (4) up. Immediately after switching on, the measuring tool sends two laser lines out of the outlet aperture (5).
- Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself (even from a distance).
To switch off the measuring tool, push the on/off switch (4 ) downward over the laser beam outlet aperture (5). The pendulum unit is locked when the tool is switched off.
- Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be blinded by the laser beam.
Automatic levelling
Position the measuring tool on a level, firm surface or attach it to the
holder (16) or the tripod (11). To work with automatic levelling, the
underside of the measuring tool needs to be horizontal and aligned with the
tripod mount (6) facing down.
After switching on, the automatic levelling function automatically compensates
irregularities within the self-levelling range of ±4°. The levelling is
finished as soon as the laser lines stop flashing.
If automatic levelling is not possible, e.g. because the underside of the
measuring tool deviates by more than 4° from the horizontal plane or the
measuring tool is held freely in the hand, the laser lines will continuously
flash slowly and the measuring tool will work without automatic levelling. The
laser lines remain switched on, but the two intersecting lines will no longer
necessarily be perpendicular to each other. To make sure that the two laser
lines are still perpendicular to one another, position the measuring tool at
an angle of 90° to the wall.
To work with automatic levelling again, position the measuring tool so that
the underside is aligned horizontally and wait for the self-levelling to be
performed. As soon as the measuring tool is within the self-levelling range of
±4° and is levelled in, the laser lines will light up continuously again.
In case of ground vibrations or position changes during operation, the
measuring tool is automatically levelled again. Upon re-levelling, check the
position of the horizontal or vertical laser line with regard to the reference
points to avoid errors by moving the measuring tool.
Working Advice
- Only the centre of the laser line must be used for marking. The width of the laser line changes depending on the distance.
Attaching using the holder (see figure A)
Using the holder (16) , you can attach the measuring tool to various
objects up to 10 to 60 mm thick, e.g. to vertical or horizontal boards or
pipes.
Loosen the fastening screw (15) of the holder, position the holder in the
desired location and retighten the fastening screw.
Place the measuring tool with the tripod mount (6) on the 1/4″ screw
(13) of the holder and tighten it to secure it on the holder applying
moderate force. Do not tighten the measuring tool firmly as this could cause
damage.
Roughly align the holder before switching on the measuring tool. To do this,
loosen the locking screw (14). Move the measuring tool into a horizontal
position at the required height (with the tripod mount (6) facing down).
Retighten the locking screw.
You can also mount the measuring tool on the holder using the adapter plate
(3).
Working with the Tripod (Accessory)
A tripod offers a stable, height-adjustable support surface for measuring.
Place the measuring tool with the 1/4″ tripod mount (6) on the thread of
the tripod (11) or a conventional camera tripod. Tighten the measuring
tool using the locking screw of the tripod.
Roughly align the tripod before switching on the measuring tool.
You can also mount the measuring tool on the tripod using the adapter plate
(3).
Working with the adapter plate (see figures B-C)
The adapter plate (3) makes it easier to accurately align the measuring
tool with a reference point and enables you to quickly attach and detach the
measuring tool.
The adapter plate (3) can be mounted on the holder (16) or tripod
(11).
– Holder: Place the adapter plate with the 1/4″ mount (1) on the screw
(13) of the holder and tighten it to secure it on the holder applying
moderate force.
Note: Loosen the locking screw (14) of the holder if you want to
change the position of the measuring tool. If the adapter plate is turned
without loosening the locking screw, the adapter plate can become loose and
the measuring tool can fall off.
– Tripod: Tighten the locking screw of the tripod in the 1/4″ mount (1) of
the adapter plate.
Press the measuring tool into the adapter plate (3) so that the locking
mechanisms of the adapter plate engage in the holes on two sides of the
measuring tool. The adapter plate can be fastened to the bottom, back and top
side of the measuring tool.
Check that the measuring tool is firmly secured.
When the adapter plate is mounted on the back, the height of the measuring
tool can be aligned. When it is mounted on the top or bottom, the measuring
tool can be aligned sideways. Turn the fine adjustment screw (2) of the
adapter plate to align the laser line with a reference point.
Laser Goggles (Accessory)
The laser goggles filter out ambient light. This makes the light of the
laser appear brighter to the eye.
- Do not use the laser goggles (accessory) as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
- Do not use the laser goggles (accessory) as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colours.
Maintenance and Service
Maintenance and Cleaning
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or
solvents.
The areas around the outlet aperture of the laser in particular should be
cleaned on a regular basis. Make sure to check for lint when doing this.
After-Sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and
repair of your product as well as spare parts. You can find explosion drawings
and information on spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you with any questions
about our products and their accessories.
In all correspondence and spare parts orders, please always include the
10‑digit article number given on the nameplate of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts
or arrange the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
You can find further service addresses at:
www.bosch-pt.com/serviceaddresses
Disposal
Measuring tools, accessories and packaging should be recycled in an
environmentally friendly manner.
Do not dispose of measuring tools or batteries with household waste.
Only for EU countries:
According to the Directive 2012/19/EU on waste electrical and electronic
equipment and its transposition into national law, measuring tools that are no
longer usable, and, according to the Directive 2006/66/EC, defective or
drained batteries must be collected separately and disposed of in an
environmentally correct manner.
If disposed incorrectly, waste electrical and electronic equipment may have
harmful effects on the environment and human health, due to the potential
presence of hazardous substances.
Only for United Kingdom:
According to The Waste Electrical and Electronic Equipment Regulations 2013
(SI 2013/3113) (as amended) and the Waste Batteries and Accumulators
Regulations 2009 (SI 2009/890) (as amended), products that are no longer
usable must be collected separately and disposed of in an environmentally
friendly manner.
1 609 92A 8MM | (08.02.2023) Bosch Power Tools
Robert Bosch Power Tools GmbH
70538 Stuttgart
GERMANY
1 609 92A 8MM (2023.02) T / 283
References
- Invented for life | Bosch Global
- The domain name bosch.mk is for sale
- Početna strana | Bosch u Srbiji
- 巧米网为您服务!(QiaoMi.com)
- Skånevik Ølen Kraftlag AS
- ЕлектроінÑтрументи Bosch | Bosch Professional
- ÐлектроинÑтрументы Bosch | Bosch Professional
- Bosch Power Tools | Bosch Power Tools
- Location selection | Bosch Power Tools
- Електроинструменти на Bosch | Електроинструменти на Bosch
- Service worldwide
- Home | Bosch Power Tools
- Bosch Elektrowerkzeuge und Zubehör | Bosch Elektrowerkzeuge
- Bosch el-værktøj | Bosch el-værktøj
- Bosch-sähkötyökalut | Bosch-sähkötyökalut
- Outillage électroportatif Bosch | Outillage électroportatif Bosch
- Home | Bosch Power Tools
- Bosch elektromos kéziszerszámok | Bosch elektromos kéziszerszámok
- Elektronarzędzia Bosch | Elektronarzędzia Bosch
- Scule electrice Bosch | Scule electrice Bosch
- Bosch električni alati | Bosch električni alati
- Bosch Услуги | Электроинструменты Bosch
- Elektrické náradie Bosch | Elektrické náradie Bosch
- Invented for life | Bosch Global
- Ana Sayfa | Bosch Türkiye
- Početna | Bosch u Hrvatskoj
- herramientasbosch.net
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>