ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum Instruction Manual

June 16, 2024
Armor All

Wet/Dry Vacuum
Operator’s Manual

VO405P 0901 4 Gallon Wet Dry Vacuum

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum 4 Gallon
Model No. VO405P 0901

FOR YOUR SAFETY
Read and understand this manual before use. Keep this manual for future reference.
Distributed by
Cleva North America
601 Regent Park Court
Greenville, SC 29607
1-866-384-8432
©2023 Energizer Auto. Armor All is a trademark of Energizer Auto and is used under license by Cleva North America, Inc.
Thank you for purchasing this Armor All® wet/dry vacuum cleaner. Feel confident that with our Armor All® wet/dry vac you are obtaining a high- quality product engineered for optimal performance.This vacuum is capable of picking up liquids and dry materials.

IMPORTANT INFORMATION
GALLONS
“Tank Size” refers to the actual tank volume and does not reflect capacity available during operation.

PEAK HP
“Peak Horsepower” is a term used in the wet-dry vac industry for consumer comparison purposes. It does not denote the operational horsepower output of a wet-dry vac, but rather the horsepower output of a motor, including the motor’s inertial contribution, achieved in laboratory testing. In actual use, motors do not operate at the peak horsepower shown.
FOR YOUR SAFETY: CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS.

WARRANTY

We take pride in producing a high-quality, durable product. This vac carries a limited two (2) year warranty against defects in workmanship and materials from date of purchase under normal household use. Please keep your receipt as proof of purchase. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state. For customer service please call 1-866-384-8432. Not Covered by Warranty:

  • Any part that has become inoperative due to misuse, negligence, direct/indirect abuse, accidents, improper maintenance, repairs, or alterations;
  • Consumables such as filters and accessories;
  • Normal wear and tear of parts and attachments, such as hose, nozzles, or casters;
  • Normal deterioration of the exterior finish due to use or exposure;
  • Any product where serial number/data label is tampered with or removed;
  • Any product purchased from an unauthorized retailer.

IMPORTANT SAFETY INSTRUCTIONS

READ AND UNDERSTAND ALL INSTRUCTIONS
BEFORE USING THIS VACUUM.
Read and understand this operator’s manual and all labels on the vacuum cleaner before operating.
Safety is a combination of common sense, staying alert and knowing how your vacuum works. Use this vacuum only as described in this manual. To reduce the risk of personal injury or damage to your vacuum, use only manufacturer recommended accessories.

SAVE THIS MANUAL FOR FUTURE REFERENCE.
When using a vacuum, basic precautions should always be followed including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:

  • Do not run vacuum unattended.
  • Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.
  • Do not vacuum, or use this Wet/Dry Vacuum near flammable liquids, gases, or explosive vapors like gasoline or other fuels, lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, or explosive dusts like coal dust, magnesium dust, grain dust, or gun powder. Sparks inside the motor can ignite flammable vapors or dust.
  • Do not run vacuum unattended.
  • Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.
  • Do not vacuum, or use this Wet/Dry Vacuum near flammable liquids, gases, or explosive vapors like gasoline or other fuels, lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, or explosive dusts like coal dust, magnesium dust, grain dust, or gun powder. Sparks inside the motor can ignite flammable vapors or dust.
  • To reduce the risk of health hazards from vapors or dusts, do not vacuum toxic materials.
  • Do not use or store near hazardous materials.
  • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
  • Do not expose to rain. Store indoors.
  • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
  • Do not use with damaged cord or plug.
  • If vacuum is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
  • Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
  • Do not run the vacuum over cord.
  • Do not handle plug or vacuum with wet hands.
  • Do not use without dust bag and/or filters in place.
  • Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  • To reduce the risk of injury from accidental starting, unplug power cord before changing or cleaning filter.
  • Do not leave vacuum when plugged in. Unplug from outlet when not in use and before servicing.
  • Turn off all controls before unplugging.
  •  Unplug before connecting or disconnecting hose, or any other accessories.
  • Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
  • Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
  • Use extra care when cleaning on stairs.
  • Use only as described in this manual. Use only manufacturer’s recommended attachments.
  • This appliance is provided with double insulation. Use only identical replacement parts. See DOUBLE INSULATION INSTRUCTIONS.

CAUTION: TO REDUCE THE RISK OF INJURY FROM MOVING PARTS – UNPLUG BEFORE SERVICING.

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK – UNPLUG BEFORE CLEANING OR SERVICING.
When using as blower:

  • Direct air discharge only at work area.
  • Do not use Wet/Dry Vacuum as a sprayer.
  • Do not direct air at bystanders.
  • Keep children away when blowing.
  • Use safety goggles.

SAVE THESE INSTRUCTIONS For Household Use Only

DOUBLE INSULATION INSTRUCTIONS

This Wet/Dry Vacuum is double insulated, eliminating the need for a separate grounding system.
Use only identical replacement parts. Read the instructions for Servicing Double-Insulated Wet/ Dry Vacuums before servicing. Use this vacuum as described in this manual. Observe the following warnings that appear on the motor housing of your vacuum.
Icon DOUBLE INSULATED – GROUNDING NOT REQUIRED – WHEN SERVICING USE ONLY IDENTICAL REPLACEMENT PARTS.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK- DO NOT EXPOSE TO RAIN. STORE INDOORS.
WARNING:   FOR YOUR OWN SAFETY, READ AND UNDERSTAND OPERATOR’S MANUAL. DO NOT RUN UNATTENDED.
DO NOT PICK UP HOT ASHES, COALS, TOXIC, FLAMMABLE OR OTHER HAZARDOUS MATERI ALS. DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS.
CAUTION: DO NOT VACUUM DRYWALL DUST, FIREPLACE SOOT, OR ASH WITH STANDARD WET/DRY FILTER. THIS TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND CAUSE DAMAGE TO MOTOR. WHEN VACUUMING FINE DUST USE A FINE DUST FILTER (SOLD SEPARATELY).
WARNING: SERVICING OF DOUBLE-INSULATED WET/ DRY VACUUMS WITH A DOUBLE- INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED ON A DOUBLE-INSULATED APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED. SERVICING A DOUBLE INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM, AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL. REPLACEMENT PARTS FOR A DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE. YOUR DOUBLE- INSULATED WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ AND THE SYMBOL (SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE APPLIANCE.

EXTENSION CORDS

When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use.

Length of Extension Cord

120V| 25ft (7.62m)| 50ft (15.24m)| 100ft (30.48m)| 150ft (45.72m)
Ampere Rating| A.W.G. Wire Size
More than| Not more than
0| 6| 18| 16| 16| 14
6| 10| 18| 16| 14| 12
10| 12| 16| 16| 14| 12
12| 16| 14| 12| Not recommended

SYMBOLS

SYMBOL SIGNAL MEANING
DANGER Indicates an imminently hazardous situation, which, if not avoided,

will result in death or serious injury.
| WARNING| Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
| CAUTION| Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.
| NOTICE| (Without Safety Alert Symbol) Indicates a situation that may result in property damage.

UNPACKING & CHECKING CARTON CONTENTS

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - CHECKING
CARTONRemove all contents from the box. Remove the powerhead and take out any contents inside the collection tank. Check each item against the carton contents list.
Carton Contents List

Key Description Qty
A Handle 1
B Vacuum Assembly 1
C Hose 1
D Extension Wands 3
E Floor Brush/Squeegee Nozzle 1
F Utility Nozzle 1
G Crevice tool 1
H Caster 4
I Reusable Cloth Filter 1
J Foam Wet Filter 1
K Operator’s Manual 1

NOTE: The hose and accessories for this vacuum are 1-1/4” (32 mm) diameter.

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - Blower
Port

GENERAL ASSEMBLY INSTRUCTIONS

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - GENERAL ASSEMBLY
INSTRUCTIONS

WARNING:
UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY DO NOT PLUG THE POWER CORD INTO A POWER OUTLET. MAKE SURE THE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VACUUM. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN.

  1. Verify that the power cord is disconnected from the outlet (Fig. 1).
  2. Undo the latches (Fig. 2).
  3. Lift the powerhead off the collection tank (Fig. 3).
  4.  Remove the contents from inside the collection tank. Make sure you have all contents as listed on page 8 (Fig. 4).
  5. Turn the collection tank upside down and insert the four casters into the sockets on the bottom of the base. Press casters down until they snap into place (Fig. 5).
  6. Insert the handle into the slots located on the top of the powerhead (Fig. 6). Apply pressure until the handle snaps into place.
  7. Your vacuum comes ready for dry vacuum cleaning. If the reusable cloth filter is not installed, refer to page 15 for installation instructions (Fig. 7).
  8. For wet vacuum cleaning, remove the reusable cloth filter, and install the supplied foam wet filter. See page 16 for the foam wet filter installation instructions (Fig. 8).
  9. Place the powerhead back on the collection tank aligning the top section with the latches, and snap into place (Fig. 9 & 10).
  10. Insert the larger end of the hose into the vacuum port on the collection tank (Fig. 11).
  11. Choose the desired accessory and insert onto the free end of the hose or extension wand (Fig. 12).

POLARIZED PLUG
To reduce the risk of electrical shock, this appliance has a polarized plug (one blade wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. Double insulation Icon eliminates the need for the three-wire grounded power cord and grounded power supply system.

DRY VACUUM OPERATION

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - DRY VACUUM
OPERATION

DRY VACUUMING
WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION ENTITLED ‘IMPORTANT SAFETY INSTRUCTIONS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR.  LAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN, OR GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
WARNING: DO NOT PLUG THE POWER CORD INTO A POWER OUTLET. MAKE SURE THE PLUG IS DISCONNECTED BEFORE CHANGING THE FILTERS.
CAUTION: DO NOT VACUUM DRYWALL DUST, FIREPLACE SOOT, OR ASH WITH STANDARD WET/DRY FILTER. THIS IS A VERY FINE DUST WHICH WILL NOT BE CAPTURED BY THE FILTER AND MAY CAUSE DAMAGE TO MOTOR. WHEN VACUUMING FINE DUST USE A FINE DUST FILTER.

  1. Verify that the power cord is disconnected from the outlet (Fig. 1).

  2. In order to prepare your vacuum for dry vacuuming, make sure the cloth filter completely covers the filter cage. Your wet/dry vacuum comes with the reusable cloth filter pre-installed. For filter installation instructions, see page 15 (Fig. 2 & 3).

  3. Place the powerhead back on the collection tank, and secure it in place using the latches (Fig. 4).
    OPERATING INSTRUCTIONS: DRY VACUUMING

  4. Insert the larger end of the hose into the vacuum port on the collection tank.

  5. Push the required accessory onto the free end of the hose or extension wand (Fig. 5).

  6. Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the power outlet. Plug the power cord into the outlet (Fig. 6 & 7).

  7. Turn the motor on by flipping the on/off switch to the ‘I’ ON position and begin vacuuming (Fig. 8).

  8. Once you have completed vacuuming, flip the switch to the ‘O’ OFF position and unplug the power cord from the outlet.

O = OFF I = ON
DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING.

LIQUID VACUUM OPERATION

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - LIQUID VACUUM
OPERATION

LIQUID VACUUMING

WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION ENTITLED ‘IMPORTANT SAFETY INSTRUCTIONS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR.  LAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN, OR GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
WARNING: DO NOT PLUG THE POWER CORD INTO A POWER OUTLET. MAKE SURE THE PLUG IS DISCONNECTED BEFORE CHANGING THE FILTERS.

  1. Verify that the power cord is disconnected from the outlet. Make sure that the collection tank is clean and free of dust and dirt (Fig. 1).

  2. Remove reusable cloth filter, then carefully install the foam wet filter over the filter cage and place the powerhead back on the collection tank. For foam wet filter installation instructions, see page 16 (Fig. 2 & 3).
    DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING.
    OPERATING INSTRUCTIONS: WET VACUUMING

  3. Insert the larger end of the hose into the vacuum port on the collection tank.

  4. Push the required accessory onto the free end of the hose (Fig. 4).

  5. Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the power outlet. Plug the power cord into the outlet (Fig. 5 & 6).

  6. Turn the motor on by flipping the switch to the ‘I’ ON position (Fig. 7).

  7. Once you have completed vacuuming, flip the switch to the ‘O’ OFF position and unplug the power cord from the outlet.

  8. After use, empty the collection tank, clean and dry the inside and outside of the collection tank (Fig. 8).

IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity. You will notice an increase in motor speed. When this happens, turn off the machine, disconnect from power supply, and drain the liquid into a suitable receptacle or drain. To continue vacuuming, refit the powerhead to the collection tank. After wet vacuuming, turn the machine off and remove plug from power supply. Empty the collection tank, clean and dry the inside and outside before storage.
REMEMBER! The foam wet filter must be removed after wet vacuuming and the reusable cloth filter must be installed before dry vacuuming again.

BLOWER OPERATION

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - BLOWER
OPERATION

This Wet/Dry vacuum has blowing capabilities. To use the blower feature, follow the instructions listed below.
WARNING: ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN CANADA, CSAZ94.3) BEFORE USING BLOWER.
WARNING: KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS.
WARNING: WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED.

  1. Verify that the power cord is disconnected from the outlet (Fig. 1).
  2. Make sure the collection tank is empty before using as a blower. Clear all dirt and debris from the hose and collection tank.
  3. Remove the hose from the vacuum port.
  4. Insert the larger end of the hose into the blower port on the back side of the powerhead (Fig. 2).
  5. Choose the desired accessory and insert onto the end of the hose (Fig. 3).
  6. Verify that the on/off switch is in the ‘O’ OFF position before plugging the power cord into the outlet. Plug the power cord into the outlet (Fig. 4 & 5).
  7. Before turning on the vacuum, firmly hold the loose end of the hose. Turn the motor on by flipping the switch to the ‘I’ ON position (Fig. 6).
  8. Once you have completed blowing, flip the on/off switch to the ‘O’ OFF position. Unplug the power cord from the outlet (Fig. 7).

MAINTENANCE

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum -
MAINTENANC

EMPTYING THE COLLECTION TANK
WARNING: ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE REMOVING THE POWERHEAD FROM COLLECTION TANK.

  1. Verify that the power cord is disconnected from the outlet (Fig. 1).
  2. Disconnect the hose from the vacuum (Fig. 2).
  3. Undo the latches and remove the powerhead from the collection tank (Fig. 3). Place power head on a soft, clean surface upside down.
  4. Clear all dirt or debris from the collection tank and hose into a proper waste container (Fig. 4).
  5. Clean or replace the filters.
  6. Check the hose, accessories, and power cord to verify that they have not been damaged.
  7. Place the powerhead back on collection tank and secure latches.

IMPORTANT! Clean or change the filter regularly for best performance. ALWAYS USE THE REUSABLE CLOTH FILTER FOR DRY VACUUMING. If the machine is used without the reusable cloth filter, the motor will burn out and the warranty will be voided. Always keep spare filters on hand.
NOTICE! The filters included are made of high-quality materials designed to stop small dust particles. The reusable cloth filter should be used for dry pick-up only. A dry reusable cloth filter is necessary to pick up dust. If the reusable cloth filter is wet, it will clog quickly and be very difficult to clean. Handle the filter carefully when removing it for cleaning and replacing it. Check the filters for tears or small holes. A small hole can let dust pass through and out of the filter. Do not use a filter with holes or tears;
replace it immediately.

STORAGE
Before storing your vacuum, the collection tank should be emptied and cleaned. The accessories should be cleaned and stored so they can be readily available when needed. Store the wet/dry vacuum indoors.

REPAIRS
Repairs for this wet/dry vacuum should be performed only by qualified service personnel using only identical replacement parts.

INSTALLING & CLEANING REUSABLE CLOTH FILTER

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - CLOTH
FILTER

INSTALLING REUSABLE CLOTH FILTER

  1. Verify that the power cord is disconnected from the outlet (Fig. 1).
  2. Remove powerhead and place in an upside-down position.
  3. Install the reusable cloth filter over the filter cage making sure the cage is completely covered (Fig. 2 & 3).
  4. Place the powerhead back onto the collection tank.

REMOVING & CLEANING REUSABLE CLOTH FILTER

  1. With the removed power head in an upside-down position, carefully remove the reusable cloth filter from the filter cage (Fig. 4).
  2. Clean the reusable cloth filter by gently tapping or brushing dirt off. Cleaning should not be done indoors in living areas. For optimal performance a new filter is recommended.
  3. Use a mild soap and water solution to wash the reusable cloth filter and rinse with clean water (Fig. 5).
  4. Allow the wet filter to air dry completely before storing or installing onto the filter cage.

INSTALLING & CLEANING FOAM WET FILTER

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - WET
FILTER

INSTALLING FOAM WET FILTER

  1. Verify that the power cord is disconnected from the outlet (Fig. 1).
  2. Remove powerhead and place in an upside-down position. Follow instructions to remove the reusable cloth filter on page 15.
  3. Carefully slide the foam wet filter down over the filter cage making sure the cage is completely covered (Fig. 2 & 3).
  4. Place the powerhead back onto the collection tank.

CLEANING FOAM WET FILTER

  1. With the removed powerhead in an upside-down position, carefully remove the foam wet filter (Fig. 4).
  2. Use a mild soap and water solution to wash foam wet filter and rinse with clean water (Fig. 5).
  3. Allow the wet filter to air dry completely before storing or installing onto the filter cage.

TROUBLESHOOTING

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE TROUBLESHOOTING.

PROBLEM POSSIBLE CAUSE SOLUTION
**** The wet/dry vacuum will not operate. No power supply. Check the

power supply, cord, breakers, and fuses.
Faulty power cord.| Unplug and check the power cord. If damaged, have it repaired by a professional.
Collection tank is full.| Empty the collection tank.
Switch in the wrong position.| Press the ON ‘I’ button on the power head.
The dust comes out from the motor cover.| The reusable cloth filter is missing or damaged.| Attach or replace the reusable cloth filter.
Reduced efficiency and motor/speed  vibration.| There are blockages in the nozzle, hose, or the collection tank inlets.| Unplug and check nozzle, hose and collection tank inlets for blockages.
The reusable cloth filter is clogged by fine dust.| Take off the filter and clean it or install a new reusable cloth filter.

EXPLODED VIEW

ARMOR ALL VO405P 0901 4 Gallon Wet Dry Vacuum - EXPLODED
VIEW

PARTS LIST

Part Part Number Description Quantity
1 551142105 Handle 1
2 Power Head Assembly 1
3 551012115 Float 1
4 551012116 Filter Cage 1
5 Collection Tank 1
6 551012104 Vacuum Port 1
7 551012121 Caster 4
8 551012127 Hose 1
9 551004114 Crevice Tool 1
10 551003109 Extension Wand 3
11 551296103 Floor Brush/Squeegee Nozzle 1
12 551004113 Utility Nozzle 1
13 551009111 Foam Wet Filter 1
14 551012110 Reusable Cloth Filter 1

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Armor All User Manuals

Related Manuals