Intel SSR316MJ2 Storage System User Guide

June 16, 2024
Intel

Intel® Storage System SSR316MJ2

Spares / Parts List & Configuration Guide

A reference guide to assist customers in ordering the necessary components to configure the Intel® Storage System SSR316MJ2.

Rev 1.5
Subject to Change

January 2006

Intel SSR316MJ2 Storage System 1

Change History:

8/11/2004 Rev. 0.9: Initial Release
9/13/2004 Rev. 1.0: Updated Base Unit Description
11/29/2004 Rev. 1.1: Removed client-server clustering optional SW
3/17/2005 Rev. 1.2: Added in spares details for CPU cooling solution (fan, heat sink, retention and wind tunnel)
7/12/2005 Rev. 1.3: Moved document from Intel Confidential status
12/27/2005 Rev. 1.35: Corrected error in configuration (removed HDDs & memory, added BBUs)
1/19/2005 Rev. 1.4: Updated document, to reflect “Mt. Jefferson Plus” configuration changes
1/24/2005 Rev 1.5: Added clarification that boxed processor ordered through distribution. Changed the picture. Fixed processor product code.


Disclaimer

Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
*Other brands and names may be claimed as the property of others. Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
All products, dates, and figures are preliminary and are subject to change without any notice.
Copyright © Intel Corporation 2003/2004.

Production Configurations
Base Unit Description

This section contains information needed to order and configure a production Intel® Storage System SSR316MJ2. The unit is shipped as a complete, fully integrated, system. The base system includes software; however there are optional software packages available to upgrade the functionality of the unit.

1) The Intel® Storage System SSR316MJ2 contains the following

  • Hardware
    • 1 x 3U system chassis (including Serial ATA hard disk drive backplane)
    • 1 x Intel® Server Board SE7501HG2
    • 16 x Intel® hard disk drive carriers (for use with Serial ATA drives)
    • 2 x Intel® RAID Controller SRCS28X
    • 2 x 700 W power supply modules
    • 16 x Serial ATA hard disk drive cable
    • 2 x compact flash readers
    • 2 x Intel® Xeon™ Processor 3.06 GHz
  • See end of this section for specifics on memory configurations. Always consult the Technical Product Specification (TPS) for the latest technical information.
  • Software
    • SAN management software (installed on unit)
    • Storage System Console (remote configuration and management tool)

2) The following optional software packages are offered as accessories for the SSR316MJ2 base unit:

  • Scalability Package: allows multiple units to pool storage and connectivity recourses
  • Configurable Snapshot Package: allows snapshots to be created automatically
  • Remote Data Protection Package: offers remote volume copy over IP networks

NOTE: Intel® Storage System SSR316MJ2 memory upgrade guideline –

Required (for functionality): 100 MB plus 200 MB per 1 TB of raw storage installed. Example: for 16 x 250 GB drives, memory requirements = 100 MB + (200 MB x 4) = 900 MB, therefore 1 GB.
Recommended (for optimum performance): 128 MB per 250 GB drive installed. Example: 128 MB x 16 = 2 GB.

Production System Codes
Product Code MM # UPC Description
SSR316MJ2  874024 00735858170000 Production Intel® Storage System SSR316MJ2

(Mt. Jefferson “Plus”) unit.
SSR316MJ2NA| 874028| 00735858170000| Production Intel® Storage System SSR316MJ2 (Mt. Jefferson “Plus”) unit with North American power cord

Production Optional Software Accessories
Product Code MM # UPC Description
AMJSWSC ** 864204 00735858170116 Scalability Package upgrade for the Intel®

Storage System SSR316MJ2. Allows multiple SSR316MJ2 units to pool storage and connectivity resources.
AMJSWSN | 864205| 00735858170123| Configurable Snapshot Package upgrade for the Intel® Storage System SSR316MJ2. Allows snapshots to be created automatically and the physical size of a snapshot to be changed.
AMJSWRM
| 864206| 00735858170130| Remote Data Protection Package upgrade for the Intel® Storage System SSR316MJ2. Allows for volumes to be copied to a remote Intel® Storage System SSR316MJ2 unit over an IP network.

** Package is pre-installed on the base production Intel® Storage System SSR316MJ2 and may be used for a 30 day trial period. To continue usage, package must be purchased and software key must be entered into each system individually via the Storage System Console. One license for each of these features can be used on up to 3 Intel® Storage System SSR316MJ2 units in the same management group.

Production Hardware Spares (Field Replaceable Units)
Product Code MM # UPC Description
FMJCABLES2 874449 00735858178020 Complete cable set. Includes 16 SATA

cables (custom length to fit Intel® Storage System SSR316MJ2 chassis), 2 IDE cables (for compact flash readers), 1 front panel cable and 3 I2C cables (for Intel® RAID Controller SRCS28X to connect to chassis backplane).
FMJFRTPANEL| 863017| 00735858170031| Front panel board assembly. Includes front panel printed circuit board with light pipes and compact flash readers.
FMJBACKPLANE2| 862952| 00735858170048| Backplane assembly for SSR316MJ2 . Includes backplane printed circuit board, power cables and bracket.
FMJBEZEL| 862953| 00735858170055| Bezel assembly. Includes chassis front bezel and 3 screws.
FMJPS700W| 862955| 00735858170062| Single power supply module (2 ship with each system).
FMJPDB| 862987| 00735858170079| Power supply distribution board.
FMJFAN| 863042| 00735858170086| Fan assembly. Includes 1 x 120 mm fan, snap rivet and bracket.

Existing Production Spares & Accessories
Product Code MM # UPC Description
SRCS28X 866296 00735858171625 Intel® RAID Controller SCRS28X (5 pack)

channel Serial ATA RAID controller. This SKU is orderable by the channel through distribution.
AXXRIBBU2| 862731| 00735858169141| Single battery backup unit (BBU) for Intel® RAID Controller SRCS28X
FXX2DRVCARBLK| 835853| 00735858146210| Single drive carrier.
BX80532KE3066DSL6VP| 854977| | Single boxed Intel® Xeon™ processor 3.06 GHz. Includes CPU, heat sink, fan, wind tunnel and retention mechanism. This SKU is orderable by the channel through distribution.
SE7501HG2| 850354| 00735858158008| Single production Intel® Server Board SE7501HG2 (minimum order quantity is 5).
Shop Intel Part Number: C91324 | N/A| N/A| Heat sink for 3.06 GHz CPU. Orderable from Shop Intel at http://www.shopintel.com/shop/product.asp?pid=SIPS1005&pfid=123&pinde x=1&mscssid=VBL9QHDPWN6M9G357FB351C7NB89DV1 D (order quantity of 1 – 20 units) Bulk purchasing can be discussed directly with the vendor, Fujikura. Contact Ash Ooe at 408-988-7405 / [email protected]. Reference Fujikura part number FHP3393 rev F (Intel part number C25846-002).
Shop Intel Part Number: C24889-001  | N/A| N/A| 38 mm fan for 3.06 GHz CPU heat sink. Orderable from Shop Intel at http://www.shopintel.com/shop/product.asp?pid=SIPS1004&pfid=122&pinde x=1&mscssid=VBL9QHDPWN6M9G357FB351C7NB89DV1 D (order quantities of 1 – 20 units) Bulk purchasing can be discussed directly with the vendor, Sanyo Denki. Contact Mamoru Yasui (Moe) at 310-783- 5423 / [email protected]. Reference Sanyo Denki part number 9G0612T1H133 (Intel part number C24889- 001).
Shop Intel Part Number: C22005-002| N/A| N/A| Processor wind tunnel (PWT) for the 38 mm fan for the 3.06 GHz CPU heat sink. Orderable from Shop Intel at http://www.shopintel.com/shop/product.asp?pid=SIPS1002&pfid=121&pinde x=1&mscssid=VBL9QHDPWN6M9G357FB351C7NB89DV1 D (order quantities of 1 – 20 units) Bulk purchasing can be discussed directly with the vendor, Professional Tool. Contact Ms Mari at 604-332-2335 ext 309 / mari @professional-tools.com. Reference Professional Tool part number PTC22005-002 (Intel part number C22005- 002).
Shop Intel Part Number: C62871-001| N/A| N/A| Retention kit for the 3.06 GHz CPU heat sink. Orderable from Shop Intel at http://www.shopintel.com/shop/product.asp?pid=SIPS1009&pfid=124&pinde x=1&mscssid=VBL9QHDPWN6M9G357FB351C7NB89DV1 D (order quantities of 1 – 20 units) Bulk purchasing can be discussed directly with the vendor, Foxconn Contact Julia Jiang (or James Hsu in Taiwan) at 408-919-6178 (886-2-2268-3466 ext.1056) / [email protected] ([email protected]). Reference Foxconn part number 028-1009-071 (Intel part number A74694-001).

NOTES:
Unless noted otherwise, all items are individually orderable.

Downloaded from Arrow.com.