Electrolux EWKIT5 Premium Window Kit Installation Guide

June 16, 2024
Electrolux

Electrolux logo

Electrolux EWKIT5 Premium Window Kit Installation
Guide

Premium Window Kit

EWKIT5

www.electrolux.com

Installation guide

Electrolux EWKIT5 Premium Window Kit Installation Guide -
a1

(1) Main panel (with clamp and cap)
(2) Telescopic panel (with clamp and cap)
(3) Fabric triangle cover (2pcs)
(4) Hole cover lid
(5) Strap with hook
(6) Hose connector (15cm diameter)
(7) Hose connector adapter
(8) Adhesive sealing strips
(9) Sealing sponge (2pcs)

Window size and space requirements for the window kit to operate

properly

(1) 1000~1350mm (without extension piece)
1350~1700mm (with extension piece)
For every extension added the size is increased by 350mm
(2) 900 ~ 1260 mm
(3) Window thickness 35 ~ 105mm
(4) The clamps require 15mm gap above and below the window frame

Suited to the following window types

Side hinged inward

Please make sure there Is enough space between the window and wall for hose mounting.

For recessed windows, the minimum distance to be able to mount the adapter part is between 120-150mm depending on the window type and structure.


Side hinged outward

In some cases, the handle can prevent the window from sealing completely.

NOT Suited to the following window types

Top hinged outward projecting (with gap at the top)

Pivot hinged vertical

Top hinged outward

Pivot hinged horizontal

Tilt and turn

Sliding

How to apply the adhesive sealing strips

| |
---|---|---
| Electrolux EWKIT5 Premium Window Kit Installation Guide -
c5

*Please keep excess adhesive sealing strips for use in the extension piece.

Inward hinged window

| |
---|---|---
Electrolux EWKIT5 Premium Window Kit Installation Guide -
c9

Extension Piece
REF : EWKEXT1
PNC : 900 923 637

|
---|---
| |
---|---|---
Electrolux EWKIT5 Premium Window Kit Installation Guide -
c15|
---|---

Outward hinged window

| |
---|---|---
Electrolux EWKIT5 Premium Window Kit Installation Guide -
d4

Extension Piece
REF : EWKEXT1
PNC : 900 923 637

|
---|---
| |
---|---|---
Electrolux EWKIT5 Premium Window Kit Installation Guide -
d10|
---|---

Install the hose connector adapter for recessed windows

| Electrolux EWKIT5 Premium Window Kit Installation Guide -
e2
---|---

Fabric cover wash instructions

Electrolux EWKIT5 Premium Window Kit Installation Guide -
e3 Electrolux EWKIT5 Premium Window Kit
Installation Guide - e4

  • Cold wash at or below 40°C.
  • Don’t bleach.
  • Do not tumble dry.
  • Iron at temperature no more than 110°C.
  • Dry clean, tetrachloroethylene (PCE) only.

www.electrolux.com / shop.electrolux.com

Extension Piece
REF : EWKEXT1
PNC : 900 923 637

Components

(1) Main panel (with clamp and cap)
(2) Telescopic panel (with clamp and cap)
(3) Fabric triangle cover (2pcs)
(4) Hole cover lid
(5) Strap with hook
(6) Hose connector (15cm diameter)
(7) Hose connector adapter
(8) Adhesive sealing strips
(9) Sealing sponge (2 pcs)

  • Extension piece for telescopic panel (NOT included in the box – can be purchased separately if needed)

Window compatibility

Window size and space requirements for the window kit to operate properly

(1) 1000~1350mm (without extension piece)
1350~1700mm (with extension piece*)

  • For every extension added the size is increased by 350mm
    (2) 900~1260mm
    (3) Window thickness 35 ~ 105mm
    (4) The clamps require 15mm gap above and below the window frame
Suited to the following window types
  • Side hinged inward:
    Please make sure there is enough space between the window and wall for hose mounting. For recessed windows, the minimum distance to be able to mount the adapter part is between 120-150mm depending on the window type and structure.

  • Side hinged outward:
    In some cases, the handle can prevent the window from sealing completely.

NOT suited to the following window types
  • Top hinged outward projecting (with gap at the top)
  • Pivot hinged vertical
  • Top hinged outward
  • Pivot hinged horizontal
  • Tilt and turn
  • Sliding
Installation guide

1. Slide the telescopic panel into the main panel.
2. Stand the window kit in the gap between the window and window frame. (It works for both right and left hinged windows.) The telescopic panels can be adjusted according to the height of the window. (The extension piece can be purchased separately for big windows.)
3. Secure the top clamp.
4. Adjust the length of panels and secure the bottom clamp.
5. Attach the fabric triangle covers to seal the top and the bottom parts of the window to stop the air from re-entering the room.
6. Hook the strap to the outside of the window frame. Close the window and attach the strap to the clamp. Pull and adjust the strap to ensure the window kit is securely in place between the window and window frame.
7. Cover the upper hole with the cover lid to prevent air re-entering.
8. Connect the hose connector to the bottom hole.
9. Connect the hose to the portable AC unit.
10. Start the portable AC unit


Fabric cover wash instructions
  • Cold wash at or below 40°C.
  • Don’t bleach.
  • Do not tumble dry.
  • Iron at temperature no more than 110°C.
  • Dry clean, tetrachloroethylene (PCE) only.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals