Electrolux EWKIT5 Premium Window Kit Installation Guide
- June 16, 2024
- Electrolux
Table of Contents
Premium Window Kit
EWKIT5
Installation guide
(1) Main panel (with clamp and cap)
(2) Telescopic panel (with clamp and cap)
(3) Fabric triangle cover (2pcs)
(4) Hole cover lid
(5) Strap with hook
(6) Hose connector (15cm diameter)
(7) Hose connector adapter
(8) Adhesive sealing strips
(9) Sealing sponge (2pcs)
Window size and space requirements for the window kit to operate
properly
(1) 1000~1350mm (without extension piece)
1350~1700mm (with extension piece)
For every extension added the size is increased by 350mm
(2) 900 ~ 1260 mm
(3) Window thickness 35 ~ 105mm
(4) The clamps require 15mm gap above and below the window frame
Suited to the following window types
Side hinged inward
Please make sure there Is enough space between the window and wall for hose mounting.
For recessed windows, the minimum distance to be able to mount the adapter part is between 120-150mm depending on the window type and structure.
Side hinged outward
In some cases, the handle can prevent the window from sealing completely.
NOT Suited to the following window types
Top hinged outward projecting (with gap at the top)
Pivot hinged vertical
Top hinged outward
Pivot hinged horizontal
Tilt and turn
Sliding
How to apply the adhesive sealing strips
| |
---|---|---
|
*Please keep excess adhesive sealing strips for use in the extension piece.
Inward hinged window
| |
---|---|---
Extension Piece
REF : EWKEXT1
PNC : 900 923 637
|
---|---
| |
---|---|---
|
---|---
Outward hinged window
| |
---|---|---
Extension Piece
REF : EWKEXT1
PNC : 900 923 637
|
---|---
| |
---|---|---
|
---|---
Install the hose connector adapter for recessed windows
|
---|---
Fabric cover wash instructions
- Cold wash at or below 40°C.
- Don’t bleach.
- Do not tumble dry.
- Iron at temperature no more than 110°C.
- Dry clean, tetrachloroethylene (PCE) only.
www.electrolux.com / shop.electrolux.com
Extension Piece
REF : EWKEXT1
PNC : 900 923 637
Components
(1) Main panel (with clamp and cap)
(2) Telescopic panel (with clamp and cap)
(3) Fabric triangle cover (2pcs)
(4) Hole cover lid
(5) Strap with hook
(6) Hose connector (15cm diameter)
(7) Hose connector adapter
(8) Adhesive sealing strips
(9) Sealing sponge (2 pcs)
-
Extension piece for telescopic panel (NOT included in the box – can be purchased separately if needed)
-
-
Window compatibility
Window size and space requirements for the window kit to operate properly
(1) 1000~1350mm (without extension piece)
1350~1700mm (with extension piece*)
- For every extension added the size is increased by 350mm
(2) 900~1260mm
(3) Window thickness 35 ~ 105mm
(4) The clamps require 15mm gap above and below the window frame
Suited to the following window types
-
Side hinged inward:
Please make sure there is enough space between the window and wall for hose mounting. For recessed windows, the minimum distance to be able to mount the adapter part is between 120-150mm depending on the window type and structure. -
Side hinged outward:
In some cases, the handle can prevent the window from sealing completely.
NOT suited to the following window types
- Top hinged outward projecting (with gap at the top)
- Pivot hinged vertical
- Top hinged outward
- Pivot hinged horizontal
- Tilt and turn
- Sliding
Installation guide
1. Slide the telescopic panel into the main panel.
2. Stand the window kit in the gap between the window and window frame.
(It works for both right and left hinged windows.) The telescopic panels can
be adjusted according to the height of the window. (The extension piece can be
purchased separately for big windows.)
3. Secure the top clamp.
4. Adjust the length of panels and secure the bottom clamp.
5. Attach the fabric triangle covers to seal the top and the bottom parts
of the window to stop the air from re-entering the room.
6. Hook the strap to the outside of the window frame. Close the window
and attach the strap to the clamp. Pull and adjust the strap to ensure the
window kit is securely in place between the window and window frame.
7. Cover the upper hole with the cover lid to prevent air re-entering.
8. Connect the hose connector to the bottom hole.
9. Connect the hose to the portable AC unit.
10. Start the portable AC unit
Fabric cover wash instructions
- Cold wash at or below 40°C.
- Don’t bleach.
- Do not tumble dry.
- Iron at temperature no more than 110°C.
- Dry clean, tetrachloroethylene (PCE) only.
Read User Manual Online (PDF format)