Getting to Know your CLEVER Thermostat
Turning your CLEVER, ON/OFF
While OFF, your CLEVER will not perform any of its functions.
Hold for 3 seconds to turn the CLEVER on, or off.
PLEASE NOTE : Frost Protection will also be inactive.
Setting the Time and Date
Hold for 3 seconds.
The format for entering the date is YY/MM/DD.
Use & to change the Year, and to confirm and move to the Month.
Repeat these steps to set the Date, Day, and the Time, then press to finish
setting and return to the main display.
Programming Modes
7 Day (07) – This mode allows you to programme all 7 days of the week
individually.
5 day & 2 day (52) – This mode allows you to programme Monday to Friday, and
Saturday to Sunday individually.
24hr (24) – This mode allows you to create a single programme which will
repeat on a daily basis.
To Select the Programming Mode
Hold & together for 3 seconds to enter the programming function.
Using the & , select the required Programming Mode.
Use to confirm your selection.
Programming Logic
When programming this thermostat you will be asked to enter a time and then
the temperature you require at that time. You can set 4 time/temperature
switches through a single day.
E.g. 07:00 & 22°C > 10:00 & 18°C > 15:00 & 22°C > 22:00 & 18°C
With these temperature settings, the heating will be increased to 22°C by
07:00 and maintain that temperature until 10:00 when the temperature
requirement will switch to 18°C, this new temperature will be maintained until
22°C is required at 15:00, 22°C will be maintained until 22:00 when only 18°C
is required. This last time setting will maintain the specified temperature
until 07:00 the next morning.
Description simplified for clarity. Building, heat up & cool down rates are not explained here, and will vary according to various external parameters. To Enter the Programme Parameters
The time display will be flashing – use & to change the hours and press to
confirm. Repeat for the minutes.
The temperature display will now be flashing – use & to select the desired
temperature and press to confirm.
Repeat these steps for the remainder of that day, then as necessary depending
on your programming mode, after that.
Manual Override
Manual Override allows you to set a temperature (higher or lower) than the
current room temperature by interrupting the current programme.
This new temperature will be maintained until the Manual Override is turned
off.
From the main display, briefly press either and , the Manual symbol will
appear and the temperature can then be changed to
the desired temperature.
Press to confirm your selection.
To cancel Manual Override press . The Manual Override will be removed, press
to return to the main display.
The CLEVER will resume the previously set programme.
Locking and Unlocking your CLEVER
Locking the CLEVER disables all the functions of the buttons and shows the
small padlock symbol in the top right of the display.
Hold & for 3 seconds. The padlock symbol will appear, indicating that the
CLEVER has been locked.
Repeat these steps to unlock the CLEVER.
Advanced Settings List
- Boost Setting – Hours and Target Temp> 5-35°C
- Holiday Setting – Days and Target Temp> 5-35°C
- Sensor Type – 00 Inner Sensor, 01 External Sensor, 02 Inner & External Sensor, Default 00
- High Temperature Protection – 35-90°C, Default 90°C
- Low Temperature Protection – 0-10°C, Default 5°C
- Swing – 1-9°C, Default 1°C
- Temperature Calibration ADJ – ±9°C, Default 0°C
- Highest Target Temperature – 35-90°C, Default 35°C
- Lowest Target Temperature – 0-30°C, Default 5°C
- Home Mode – Temperature Setting 5-25°C, Default 22°C
- Away Mode – Temperature Setting 5-25°C, Default 15°C
- Sleep Mode – Temperature Setting 5-25°C, Default 18°C
- Restart Thermostat / Reset Thermostat –
a. Screen shows ‘ ’
b. Press or and the screen will change to ’
c. Wait 10 seconds or press button to confirm setting
Advanced Settings
From here you can access the Advanced Settings for your CLEVER. These settings
will allow you to personalise the way your CLEVER
works. To access the Advanced Setting Menu:
Hold & for 3 seconds.
Use to switch between the Advanced Settings. Use & to make changes to the
chosen Advanced Setting.
Once you have finished altering the Advanced Settings, press to confirm
changes and return to the main display.
Connecting your CLEVER to the Unisenza App
Search your App Store for “Unisenza” and download
|
---|---
https://apps.apple.com/it/app/emmeti-zona/id1466927132|
https://play.google.com/store/apps/details?id=com.emmeti.smart&hl=en_SG
Advanced Modes
Your CLEVER thermostat can be set on 6 different modes as shown below:
MODE | DESCRIPTION | RANGE |
---|---|---|
AUTO | If you have entered any of the other modes AUTO will return you to your | |
current programme. | – | |
SLEEP | The standard night set back temperature. | 5°C – 25°C |
HOME | Used as an override to the current setting i.e. If you are home during | |
the day when your programme may be at a low temperature. | 5°C – 25°C | |
AWAY | This is a setback temperature which your CLEVER will maintain if you | |
are away for a short time. | 5°C – 25°C | |
HOLIDAY | Set a specific temperature for the heating while you are away for a | |
prolonged time. | Up to 99 days | |
BOOST | Override the temperature on the thermostat for a specific amount of | |
time. | Up to 24 hours |
CLEVER Operating Instructions