Specifications:

  • Product Type: GreenUp Wellglass/LED
  • Voltage (v): 220-240
  • Frequency (Hz): 50/60
  • Power (w): 29 (BY200P LED32 L-B/CW PSU), 40 (BY200P LED44 L-B/CW PSU)
  • CCT: 6500K (BY200P LED32 L-B/CW PSU), 4000K (BY200P LED32 L-B/NW PSU, BY200P LED44 L-B/CW PSU, BY200P LED44 L-B/NW PSU)
  • Dimension (mm): DWH
  • Accessory: BY200Z MB/2.3, BY200Z WG/, BY200Z MB/2.7, BY200Z WG L/

Mounting Instructions:

Bracket Mounting:

  1. Mount the grommet to the screw hole.
  2. Bracket mounting is for indoor use only.
  3. Mount the bracket kit using the following components:
    • Housing
    • Toothwasher/D6
    • Bracket
    • Flat washer/D6
    • Spring washer/D6
    • Screw/M6
  4. Adjust the mounting angle as desired.
  5. Lock screws with Allen key-5 (GB/T5356-5) to a torque of 8N.m.

Pipe Mounting:

  1. Mount the luminaire to the end of the pipe.
  2. Lock the screw with Allen key-2 (GB/T5356-2) to a torque of 2.5N.m.
  3. Pipe dimension: 20-25mm
  4. A G3/4″ pipe size is required.

WG Mounting:

  1. Mount the luminaire using the provided G3/4″ pipe (not provided) or optional accessory BY200Z WG/WG L.
  2. Tighten the screw with a torque of 1N.m.

Cable Connection:
Please use an IP65 or above cable connection box (not provided). The inside of the cable connection box should have a fixed device for wire connection. Connect the brown wire to the live wire and the blue wire to the neutral wire. The dimensions for the cable connection box are 40mm x 28mm x 7mm (6-13).

Product Usage Instructions

  1. Please read this manual carefully before using the product. Keep the manual for future reference.
  2. The luminaire must be installed by a qualified electrician and wired by the latest IEE electrical regulations or national requirements.
  3. Do not use the luminaire in explosive atmospheres or areas with explosive dust.
  4. The luminaire is not designed for floodlighting and should not be used as a floodlight.
  5. Use Z type connection for the luminaire cable. If the wire is broken, the luminaire must be scrapped.
  6. Replace any cracked safety screens.
  7. Clean the luminaire regularly (recommended twice a year) using a soft cotton cloth only.
  8. Avoid exposing the luminaire to corrosive atmospheres or hazardous materials such as sulfur, chlorine, phthalate, etc.
  9. The light source should only be replaced by the manufacturer, their service agent, or a similar qualified person.

FAQ:

  • Q: Can I use the luminaire outdoors?
    A: No, bracket mounting is for indoor use only. The luminaire is not designed for outdoor use.

  • Q: What type of cable connection box should I use?
    A: Use an IP65 or above cable connection box. Please note that the cable connection box is not provided with the luminaire.

  • Q: How often should I clean the luminaire?
    A: It is recommended to clean the luminaire twice a year using a soft cotton cloth only.

  • Q: How should I dispose of the product?
    A: This product should not be disposed of with other household wastes. To prevent harm to the environment and human health, recycle it responsibly. Use return and collection systems or contact the retailer where the product was purchased for safe recycling.

Specification

Mounting Instruction

Pipe Mounting
  1. Must to be mounted to the end
  2. Lock the screw with Allen key-2 GB/T 5356-2

Pipe dimension

The pipe is not provided

WG Mounting

BY200Z WG./WG L, Optional accessory

Cable Connection

Please use IP65 or above cable connection box. It is not provided. The inside of the cable connection box should have a fixed device wire

  • Power Cable: 60245IEC57 3×1.0~1.5mm2
  • Brown –L
  • YellowGreen –G
  • Blue –N

Connect to the customer’s cable connection box.

Safety Instruction

  1. Please read this manual carefully before using the product. Please keep the manual for reference later.
  2. The luminaire shall be installed by a qualified electrician and wired according to the latest IEE electrical regulations or national requirements.
  3. The luminaire must not be used in an explosive atmosphere or explosive dust.
  4. The luminaire is designed to resist wind force under unexpected conditions. The luminaire shall not be used as a floodlight, and the photometric of the luminaire is not designed for floodlighting.
  5. The cable of the luminaire should use a “Z” type connection. The luminaire has to be scrapped if the wire is broken.
  6. Please replace any cracked safety screen.
  7. To ensure optimum performance, please clean the luminaire regularly (recommended twice a year). When cleaning the luminaire, please use a soft cotton cloth only.
  8. The corrosive atmosphere or hazardous materials such as sulfur, chlorine, phthalate, etc must be avoided during the use and storage.

The light source contained in this luminaire should only be replaced by the manufacturer his service agent or a similar qualified person.

This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Signify (China) Investment Co., Ltd.

  • Building No. 9, Lane 888 Tianlin Road, Minhang District, Shanghai, China.
  • Postal code: 200233

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals