neptronic BM060 Control Actuators Instruction Manual
- June 16, 2024
- neptronic
Table of Contents
neptronic BM060 Control Actuators
Specifications
- Model: BM060 Actuator
- Torque: 50 in.lb. (5.6 Nm)
- Fail-Safe: Yes
- Operating Control: Type 1
- Voltage: Rated voltage 20 to 30 seconds torque dependent
- Humidity Range: 5 to 95% non-condensing
- Weight: 3 lb. (1.4 kg)
- Certification: ISO 9001:2015
- Compliance: UL 60730-1 & UL 60730-2-14, CSA E60730-1 & CSA E60730-2-14, Low Voltage Directive, Electromagnetic Compatibility Directive, Electrical Equipment (Safety) Regulations, Electromagnetic Compatibility Regulations
Features
- Electric actuator
- Independently mounted
- Optional BB Cable-01
Description
The BM060 Actuator is an electric actuator with a torque of 50 in.lb. (5.6
Nm) and a fail-safe feature. It operates as a Type 1 control and is
independently mounted. It is certified with ISO 9001:2015 and complies with
various safety regulations and directives.
Mechanical Installation
When installing the BM060 Actuator, follow these dimensions:
- A = 1.50″ (38mm)
- B = 3.64″ (93mm)
- C = 6.60″ (168mm)
- D = 3.02″ (77mm)
Wiring
It is strongly recommended to wire the BM060 Actuator to a separate
grounded transformer that solely serves these products. This will prevent
interference and potential damage to incompatible equipment. Refer to the
provided PCB Analog wiring configuration for proper installation.
Settings
The BM060 Actuator has DIP switches for various settings:
| Feature| OFF| ON
---|---|---|---
1| Control Input Signal| | ✓
2| Rotation| ✓|
3| Fail-safe direction| | ✓
4| Running Time speed| | 30 sec *
- Default setting with green status LED.
Auto-Stroke Adjustment
The auto-stroke feature of the BM060 Actuator is disabled by default but
can be activated manually. To initiate the auto-stroke process:
- Press and release the push button while the unit is in normal operating mode (status LED flashes slowly 1Hz).
- The actuator will travel in both directions to find its limit and position itself according to the demand.
- The LEDs will extinguish when the process is complete.
- The status LED will then continue flashing slowly (1Hz).
BX Connector Attachment Installation
-
Remove the strain release NP NEP617-2 by turning it
counterclockwise and slide it off the wires. -
Insert the conduit attachment and turn it clockwise until it
has been properly tightened onto the actuator attachment.
Recycling
At the end of its life, please return the BM060 Actuator to your Neptronic
local distributor for recycling. To find the nearest Neptronic authorized
distributor, consult www.neptronic.com.
FAQ (Frequently Asked Questions)
- Q: Can I press the clutch when the actuator is in operation?
- A: No, pressing the clutch during actuator operation can cause mechanical failure. Avoid doing so.
Models
BM060 Actuator: 50 in.lb. (5.6Nm) with fail-safe
Features
- Contactless feedback positioner
- Mounts easily on round and square shafts
- Manual clutch
- Maintenance-free
- Position indicator
- FT6 18/4 cable with strain release NP NEP617-2 (P/N: BB Cable-01) (optional)
- ½” (16mm) BW BXCON-1 conduit connector (optional)
- 2-10Vdc Feedback
- AC2-B adjustable auxiliary switch (optional)
- Fail-safe by Enerdrive System
Description | BM060 Actuator |
---|---|
Torque | 50 in.lb. [5.6 Nm] at rated voltage |
Running Time (for 90° Rotation) | 20 to 30 seconds torque dependent |
Fail Safe (Enerdrive) | Yes |
Fail Safe Runtime (0° to 90°) | 30 seconds |
Capacitor Charge Time on / Power-up | 60 seconds |
Power Consumption | 10VA peak, 5VA (during operation) |
Overload Protection | Electronic throughout, 0° to 90° rotation |
Power Supply | 22 to 26 Vac |
Transformer Requirements | Class 2; min. 36VA |
Cable | Optional 4-wire FT6 plenum cable (part#: BB Cable-01) (18AWG) with |
strain release (NP NEP617-2)
Electrical Connection| Optional BX conduit connector (BW BXCON-1)
Impedance| 100k ohms
Control Signals| 2-10Vdc (default), 0-10Vdc or 4-20mA
Feedback Signals| 2-10Vdc (default) or 0-10Vdc
Angle of Rotation| 0° to 90°, mechanically adjustable (default: 90° stroke)
Direction of Rotation| Reversible, CW: Clockwise, CCW: Counter Clockwise
(default: CW)
Cycles| 100,000 full cycles, 1,500,000 repositions
Noise Produced| 45 dB(A)
Ingress Protection| IP22 equivalent to Nema type 2
Operating Temperature| 0°F to +122°F [-18°C to +50°C]
Storage Temperature| -22°F to +122°F [-30°C to +50°C]
Relative Humidity| 5 to 95% non-condensing
Weight| 3 lb. [1.4kg]
Purpose and Action of Control| Type 1 operating control, electric actuator
Construction of Control| Independently mounted
Pollution Degree| 2
Impulse Voltage| 330V
Quality Management System| ISO 9001:2015
Certification
| Complies to standards: UL 60730-1 & UL 60730-2-14, CSA E60730-1 & CSA
E60730-2-14
Complies to Low Voltage Directive & Electromagnetic Compatibility Directive
Complies to Electrical Equipment (Safety) Regulations & Electromagnetic
Compatibility Regulations
WARNING: Risk of mechanical failure. Do NOT press clutch when actuator is in
operation.
Applications
- Small dampers
- Unit ventilators
- 1/4 turn valves
- VAV box control
- Fan coils
Dimensions
- A = 1.50” (38mm)
- B = 3.64” (93mm)
- C = 6.60” (168mm)
- D = 3.02” (77mm)
Mechanical Installation
- Manually close the damper blades and position the actuator to 0º or 90º.
- Slide the actuator onto the shaft.
- Tighten the nuts on the “U” bolt to the shaft with an 8mm wrench to a torque of 60 in-lb [6.7 Nm].
- Slide the mounting bracket under the actuator. Ensure free movement of the slot at the base of the actuator. Place the bracket pin at mid-distance of the slot.
- Affix the bracket to the ductwork with #8 self-tapping screws.
Wiring
We strongly recommend that all products be wired to a separate grounded
transformer and that transformer shall service only these products. This
precaution will prevent interference with, and/or possible damage to
incompatible equipment.
PCB
Analog
*Optional cable color code.
Note** : In the above wiring configuration, connect a supplied 500 Ohm resistor between pins 1 and 3 for a 4-20mA feedback.
Settings
DIP Switches
| Feature| OFF| ON
---|---|---|---
1| Control Input Signal| 2-10Vdc | 0-10Vdc
2| Rotation| CW | CCW
3| Fail-safe direction| at 0° | at 90°
4| Running Time speed| 90 sec| 30 sec
- = default
Green Status LED
State | Description |
---|---|
Flash | Normal operation |
Two flashes | Position sensor defect |
Three flashes | Over torque |
Rapid flash | During the charging of capacitors |
Auto-Stroke Adjustment
As a default, the auto-stroke feature is disabled and can only be activated manually. To initiate an auto-stroke process, press and release the push button while the unit is in the normal operating mode (status LED flashes slowly 1Hz). The status (green) LED will remain lit. The actuator travels in both directions to find its limit and position itself according to the demand. The LEDs will extinguish when the process is complete. The status LED will then continue flashing slowly (1Hz).
BX Connector Attachment Installation
- Remove the strain release NP NEP617-2 by turning it counterclockwise and sliding it off the wires.
- Insert the conduit attachment and turn it clockwise until it has been properly tightened onto the actuator attachment.
Recycling at end of life: please return this product to your Neptronic local distributor for recycling. If you need to find the nearest Neptronic authorized distributor, please consult www.neptronic.com.
neptronic.com | 514-333-1433 | contact@neptronic.com