ASK-42703-PSI1 Pressure Injectable Arrowg ard Blue Plus Three Lumen CVC PSI Kit Instruction Manual

June 16, 2024
Arrow

ASK-42703-PSI1 Pressure Injectable Arrowg ard Blue Plus Three Lumen CVC PSI Kit Instruction Manual

Representative photo(s): actual product specifications may vary from that shown in the photo

Pressure Injectable Arrowg +ard Blue
Plus Three-Lumen CVC/PSI Kit for use with 7 – 7.5 Fr. Catheters
CVC/PSI KIT: 3L 7FR X 16CM/8.5FR X 10CM
SKU / Article #: ASK-42703-PSI1

Highlights

Antimicrobial: Arrowg+ ard Blue Plus* Sharps Safety

Considerations

*Chlorhexidine
Not made with natural rubber latex.
±Precaution: Contains Phthalate: DEHP

Sales Quantity/Case: 5

Pressure Injectable Arrowg + ard Blue Plus® Three-Lumen CVC/PSI Kit for use with 7 – 7.5 Fr. Catheters SKU / Article #: ASK-42703-PSI1

Quantity| Component Description
1| Arrowg+ard Blue Plus ®1 Three-Lumen Catheter: 7 Fr. (2.5 mm OD) x 16 cm, Pressure Injectable
1| Arrow-Flex ® Sheath: 8.5 Fr. (2.8 mm tip ID) x 10 cm and Tissue Dilator
1| Spring-Wire Guide, Marked:.035″ (0.89 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
1| Spring-Wire Guide, Marked:.032″ (0.81 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
2| Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1| Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm)
2| Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW
1| Pressure Transduction Probe

Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC/PSI Kit for use with 7 – 7.5 Fr. CathetersSKU / Article #: ASK-42703-PSI1

Quantity| Component Description
1| Injection Needle: Eclipse™2 25 Ga. x 1″ (2.54 cm) RW and 3 mL Luer- Lock Syringe
1| Syringe: 10 mL Luer-Lock
2| Arrow ® Raulerson Spring-Wire Introduction Syringe: 5 mL
1| Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
1| Obturator: 8 Fr.
1| Cath-Gard ® Catheter Contamination Shield: 80 cm with Sterile Tape
1| SecondSite ™ Adjustable Hub: Fastener
1| SecondSite ™ Adjustable Hub: Catheter Clamp
1| SharpsAway® Disposal Cup
1| SharpsAway® II Locking Disposal Cup
1| Drape: 30″ x 36″ (76 cm x 91 cm) with 3″ (7.6 cm) fenestration, with adhesive
1| Needle Holder
1| Safety Scalpel: #11
1| Stopcock: 3-way High-Flow
1| Checklist/CLIP Sheet
1| Sterile Procedure Sign
3| Dressing: Tegaderm®3 4″ x 4-3/4″ (10 cm x 12 cm)
4| Gauze Pad : 2″ x 2″
10| Gauze Pad: 4″ x 4″
1| Suture: 3-0 Braided Silk with Straight Needle
1| Suture: 3-0 Silk with Curved Needle
1| Tubing±: 20″ (50 cm) Extension
4| Clearlink™4 Luer-Activated Valve
1| HemoHopper® Fluid Receptacle

  1. Licensed under US Patent No. 7,329,412.
  2. A trademark of Becton, Dickinson and Company.
  3. A registered trademark of 3M Company.
  4. A trademark of Baxter International, Inc.

Documents

The products in this catalog may not be available in all countries. Please contact your local representative.

Indications, contraindications, warnings and instructions for use can be found in the Product Instructions for
Use available under the Documents section on this page, where an IFU is available.

© 2023 Teleflex Incorporated. All Rights Reserved.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals

Related Manuals