Description
The Ventilation Fan by VEVOR is a high-quality fan designed to improve air circulation and remove odors and moisture from enclosed spaces. It is suitable for use in bathrooms, kitchens, garages, and other areas where proper ventilation is required.

Features

  • Powerful motor for efficient airflow
  • Easy installation with included mounting hardware
  • Durable construction for long-lasting performance
  • Quiet operation to minimize noise disruption
  • Energy-efficient design to save on electricity costs
  • Compatible with standard ductwork

Package Contents
The package includes the following items:

  • Ventilation Fan unit
  • Mounting hardware (screws, brackets)
  • User Manual

Safety Information
Prior to installing and using the Ventilation Fan, please read and understand the following safety precautions:

  • Always disconnect the power supply before servicing the fan, motor, or junction box.
  • Installation work must be carried out by a qualified person according to local and safety codes.
  • Follow all local building, safety, and electrical codes to ensure proper installation and operation.
  • Do not reduce the size of the ductwork, as it may increase fan noise.
  • Before servicing or cleaning the unit, shut off the power supply at the panel and lock it to prevent accidental power-on.
  • Use the Ventilation Fan as intended by the manufacturer. If you have any questions, contact customer service.

Installation Instructions
Please follow these instructions carefully for proper installation of the Ventilation Fan:

  1. Review all safety precautions mentioned above.
  2. Turn off the electricity at the breaker box before beginning installation.
  3. Choose the desired location for the fan in the ceiling. For optimal performance, select a location with a short duct run and minimal elbows.
  4. Using the provided template, cut an opening in the ceiling that measures 7.68 in. x 7.6 in.
  5. Securely mount the fan using the included mounting hardware, following the instructions in the user manual.
  6. Connect the fan to the power supply according to the provided wiring diagram and quick connector instructions.
  7. Once installation is complete, turn on the power supply and test the fan for proper operation.

Maintenance
To ensure optimal performance and longevity of your Ventilation Fan, follow these maintenance guidelines:

  • Regularly clean the fan blades and housing to remove dust and debris buildup.
  • Check for any loose connections or signs of wear and tear. Tighten or replace parts as necessary.
  • Inspect the ductwork for any obstructions or damage. Clear or repair as needed.
  • Refer to the user manual for any additional maintenance recommendations specific to your model.

Troubleshooting
If you encounter any issues with your Ventilation Fan, refer to the troubleshooting section in the user manual. If the problem persists, please contact our technical support for assistance.

FAQ

  • Q: Can the Ventilation Fan be used in a commercial setting?
  • A: Yes, the Ventilation Fan is suitable for both residential and commercial applications.
  • Q: What is the warranty period for the Ventilation Fan?
  • A: The warranty period for the Ventilation Fan is [Warranty Period]. Please refer to the E-Warranty Certificate for more details.
  • Q: Can I use the Ventilation Fan with a dimmer switch?
  • A: No, the Ventilation Fan should not be used with a dimmer switch. It is designed to operate at full power for optimal performance.
  • Q: Can the Ventilation Fan be installed in a sloped ceiling?
  • A: The Ventilation Fan is designed for installation in flat ceilings. Installing it in a sloped ceiling may affect its performance.

We continue to be committed to providing you tools with at competitive prices. “Save Half”, “Half Price” or any other similar expressions used by us only represent an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and do not necessarily mean covering all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are saving half in comparison with the top major brands.

NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us:

Technical Support and E-Warranty Certificate www.vevor.com/support

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

READ AND SAVE THESE INSTRUCTIONS

TYPICAL INSTALLATION

VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(1\)

PACKAGE CONTENTS

VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(2\)

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate, or install the product.

WARNING:

  • To Reduce The Risk Of Fire Or Electric Shock. Do Not Use This Fan With Any Solid-State Speed Control Device. Include instructions about a risk of fire, electric shock, or injury to persons, for cleaning and user-maintenance, such as lubrication.
  • DO NOT operate any fan with a damaged cord or plug. Discard the fan or return it to an authorized service facility for examination and/ or repair.
  • DO NOT run the cord under the carpeting. Do not cover the cord with throw rugs, runners, or similar coverings.
  • DO NOT route the cord under furniture or appliances. Arrange the cord away from the traffic area so that it will not be tripped over. Disconnect theappliance from the power supply before servicing.
  • Regular Check : Have your wall fan checked regularly for any sign of malfunction! Stop using, Check if the Plug, cord, or appliance is damaged. Excessive noise, unpleasant odor, or abnormal heat.
  • This appliance is not intended for use by people( including children)with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision instruction concerning the use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Close supervision is necessary when any appliance is used by or near children. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be done by children unless they are older than and supervised.
  • Use the appliance only for intended household purposes as described in this User Manual. Any other use is not recommended that may cause fire electric shock, or injury to people.
  • The ducted fan shall not be intended to be mounted in a duct to move

Heated air

Other safety rules

  1. Always disconnect the power supply before servicing the fan, motor, or junction box.
  2. Installation work must be out by a qualified person(s) by all local and safety codes including the rules for fire-rated construction.
  3. Follow all local building, safety, and electrical codes, as well as NEC( National Electrical Code) and OSHA( Occupational Safety and Health Act).
  4. The electric service supply must be 120 volts, 60 hertz.
  5. This unit must be properly grounded.
  6. Do not bend or kink the power wires.
  7. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
  8. Sufficient air supply is required for proper combustion and the exhaustion of gases through the chimney(flue) of fuel-burning equipment to prevent back-drafting.
    • See the standards of NFPA( National Fire Protection Association) ASHRAE( American Society for Heating Refrigeration and Air Conditioning Engineers ) and the local building code authorities.
  9. Do not use this fan with any solid-state control device, such as a remote control, dimmer switch, or certain timers. Mechanical timers are not solid-state devices.
  10. This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI-protected circuit. Do not use fans over a bathtub or shower that are not approved for that application and marked accordingly.
  11. Do not install in a cooking area.
  12. Do not use it to exhaust hazardous or explosive vapors.
  13. Fans should always be vented to the exterior and in compliance with local codes.
  14. Do not install in a ceiling with insulation greater than R50.
  15. Ductwork should be installed in a straight line with minimal bends.
  16. The duct work size must be the same as the discharge and should not be reduced. Reducing the duct size may increase fan noise.
  17. Before servicing or cleaning this unit, shut off the power supply at the panel and lock it to prevent the power from being turned on. If the panel cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on.
  18. Use this unit in the manner intended by the manufacturer. If you have any questions, please call customer service.

READ AND SAVE THESE INSTRUCTIONS

PREPARATION
Before beginning assembly of the product, make sure all parts are present. Compare parts with the package contents list and hardware contents. If any part is missing or damaged, do not attempt to assemble the product. Estimated Assembly Time: 30 minutes

Tools Required for Assembly( not included):
Hammer, Flathead Screwdriver, Wood Screws, Duct Tape Philips Screwdriver, Utility Knife Helpful Tools (not included) Electric Drill, Drill Bits.

WARNING : Turn off the electricity at the breaker box before beginning installation.

  • Carefully remove the unit from the carton.
  • Check the area above the installation location to be sure that wiring can run to the planned location that ductwork can be run and that the area is sufficient for proper ventilation.
  • Inspect ductwork and wiring before proceeding with the installation.
  • Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
  • You may need the help of a second person to install this fan: one person on the attic side and one on the room side.

Note : Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included; however, most are available at your local home improvement or hardware store.

WIRING DIAGRAM

VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(3\)

WARNING :
Wiring must comply with all applicable electrical codes. Turn OFF the power before removing or installing connectors.

WARNING :
COPPER TO COPPER ONLY. Do not use aluminum wire.

CAUTION :
The accessory part (quick connector) should meet the installation instructions below.

NOTE :
The connector is reusable on solid wires of the same wire gauge or smaller. Do not reuse the connector on stranded wires.

  1. Strip wires 3/8 in. – 1/2 in.
  2. Grip the wire firmly and push the stripped end of the wire into the open port of the connector. Use only one connector per port.
  3. Verify the stripped end of the wires is fully inserted into the back of the connector. (See the Fig.1.)

NOTE :
Important wire information. Maximum temperature rating 221˚F(105˚C). 600 volts maximum for building wire 1,000 volts maximum for building wire and 1,000 volts maximum for signs and lighting fixtures.

The acceptable wire range includes Solid: 12-18 AWG.

VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(4\)

INSTALLATION INSTRUCTIONS

Review all safety precautions. Make sure the electricity at the breaker box is turned off before beginning installation.

  1. Choose the location for your fan in the ceiling. For the best possible performance, use the shortest possible duct run and a minimum number of elbows. Then, Cut an opening that measures 7.68 in. x 7.6 in.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(5\)
    NOTE: You can also use a pen to mark the fan housing and cut holes according to the marked size.VEVOR-BT-BPT190BL-Ventilation-Fan-fig-
\(6\)

  2. Place the fan housing next to a ceiling joist or wall stud. The fan housing should be level and perpendicular to the ceiling joist or wall stud.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(7\)

  3. Mount the fan housing to the ceiling joist or wall stud using the wood screws (included) where indicated.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(8\)
    NOTE : You can use a pen to mark the keyhole slot on both mounting brackets. Screw in the wood screws using the marked positions. Reserve a 3-5mm length for the screw head. Then hang the fan onto the mounting plate and tighten the screws.VEVOR-BT-BPT190BL-Ventilation-Fan-fig-
\(9\)

  4. Remove the wiring box cover from the fan housing with a Phillips screwdriver (not included).VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(10\)

  5. Use a quick connector to secure the 120 VAC house wiring from the wall switch to the fan. 14 AWG is the minimum wire used for branch circuit wiring. Carefully push the connected wires back into the wiring box housing. Reattach the wiring box cover.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(11\)
    CAUTION :
    If the electrical wires do not match the colors listed, you must determine what each house wire represents before connecting. You may need to consult an electrical contractor to determine safety.

  6. Install a circular 4 in. duct (not included) and secure it with duct tape or clamps (neither included). Finish ceiling work. The ceiling hole should be aligned with the edge of the fan housing.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(12\)

  7. Carefully connect the light wires.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(13\)
    NOTE: Model NO: BT-BPT280AS also has a colored light power cable, please be careful to connect it at the same time.VEVOR-BT-BPT190BL-Ventilation-Fan-
fig- \(14\)

  8. Pinch mounting springs on the grille and insert them into narrow rectangular slots inside the fan housing. Push the grille up toward the ceiling.

  9. Push the grille against the ceiling. Complete installation.VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(15\)

REMOTE CONTROL INSTRUCTIONS

VEVOR-BT-BPT190BL-Ventilation-Fan-fig- \(16\)

  1. Match code:
    Holding the Match code button within 5 seconds after one sound of power on, until you hear Didi twice successfully match the code.

  2. Light switch:
    When the wall control switch is turned on, the default light is on, and the light is on neutral light;

  3. Light color temperature adjustment: When the light is Turn on, use the “Light color temperature adjustment” button to adjust the color temperature;

  4. Use the “+” button on the “Light color temperature Adjustment” button to increase the color temperature;

  5. Use the “-” button on the “Light color temperature Adjustment” button to reduce the color temperature;

  6. Light brightness adjustment : Turn on the light and use the “Brightness adjustment” button to adjust the brightness when the light is on;

  7. Use the “+” button on the “Brightness adjustment” button to increase brightness;

  8. Use the “-” button on the “Brightness adjustment” button to reduce brightness;

  9. Timing function:

  10. Timing: 30 minutes, 60 minutes, 90 minutes, 2 hours.

  11. Fan Switch:
    If the fan is running, you can directly select gears 1-6. If the fan is in a shutdown state, press the “ Fan switch ” button and the fan will start running. You can choose your gears according to your needs;

  12. Colors Light Switch:
    Model NO: BT-BPT280AS with color lighting function; The colored light function is disabled by default. Press the “ Colors light switch ” button to turn on the colored light, and continuously press the “ Colors light switch ” button to have 7 colors that can be cycled.

CARE AND MAINTENANCE

WARNING : Disconnect the power supply before servicing. See SAFETY INFORMATION before proceeding. Routine maintenance should be done at least once a year.

  • Wash the grille with mild soap and water, and dry it with a cloth.
  • Remove excess dirt and dust from the fan housing with a vacuum cleaner.
  • Do not use solvents, thinner, or harsh chemicals for cleaning the fan.
  • Do not allow water to enter the motor.
  • Do not immerse resin parts in water over 60º C.

TROUBLESHOOTING

Excessive noise

  1. It is normal that there is noise during operation. If too loud, please set the fan to a lower speed.
  2. Check if the blade is installed properly.

The fan does not operate

  1. Make sure the fan is connected to a powered electrical outlet.
  2. Clean the blade regularly.