OONO F-1057 Switching Electric Heating Relay Instructions

June 16, 2024
OONO

OONO F-1057 Switching Electric Heating Relay

OONO F-1057 Switching Electric Heating Relay

IMPORTANT!

⯈THIS MODULE OPERATES ON A HAZARDOUS VOLTAGE!
⯈All wiring must comply with national and local electrical code regulations.
⯈Installation should be carried out by an electrician.
⯈ Disconnect power supply before installing the relay to prevent electrical shock.

Features

  • The F-1057 Electric Heating Relay is designed to control a AC 120V line voltage resistive load from a low voltage thermostat. The F-1057 relay has a built-in 24 V transformer and is compatible with 3-wire (R, C, W) thermostats as well as 2-wire (R, W) mechanical and battery-operated thermostats.
  • LED indicator for relay action. On a call for heat, the relay is immediately activated, there is no delay.
  • Polycarbonate plastic enclosure, all wires lead out via 1/2” mounting nipple, it can be flexible mounting with your junction box / outlet box. Two screw mounting holes are convenient for you to fix it on the wall or wooden board.
  • Packing list: 1x relay module, 1x NPT 1/2” Zinc alloy conduit locknut, 2x M3x50mm screws.

NOTE: Not recommended for fast-cycling modulated regulation. For fast- cycling heating equipment, you may muse use Solid State Relay.

Electrical Specifications

ectrical Specifications:
Voltage: 120 VAC
Resistive load: 22 Amp, Inductive load: 0.8 HP, FLA: 16, LRA: 42
Control signal: 24 VAC / 40 mA / 1.2 VA
Transformer ratings: 24 VAC / 1.2 VA / Class 2
Wire size: 12 AWG(red, black), 16 AWG(white, yellow, green, blue) Ambient operating temperature: -20C to 60C
Net weight: 6.7 oz (190 g)

DANGER !!!

  • Do not open the housing in order to avoid the risk of electroshocks.
  • This module operates on a dangerous AC voltage !
  • All repairs should be executed by qualified technicians

SAFETY INSTRUCTIONS !!!

  • Do not attempt to disassemble the unit as it does not contain any parts that are to be serviced by the
    user. (Tampering voids warranty)

  • Do not touch unused terminals when the module is connected to the AC power.

  • Handle the module gently and carefully. Dropping it can damage the circuit board and case.

  • Never exceed the protection limit values indicated in the specifications.

  • As safety requirement vary, please check with your local authorities.

  • Disconnect the module from the AC power before connecting new devices.

  • Wipe the device with a dry and clean cloth. Do not use detergents or other liquids that may damage the housing.

  • Keep the device away from children.

  • Facilitate the operation of the device by familiarising yourself with its adjustments and indications.

  • CZH-LABS and Electronics-Salon modules are not suitable for use or as part of life support systems, or systems that might create hazardous situations of kind۔

Typical Wiring Diagrams

Conenction to a 2- wire low voltage thermostat

You must provide an overload protection and disconnect as required.

Connection to a 3-wire low voltage thermostat

You must provide an overload protection and disconnect as required.

Dimensions

Dimensions

czh-labs.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals