Weldmuller AAP21 4 DT Modular Distribution Terminals Instruction Manual
- June 15, 2024
- Weldmuller
Table of Contents
Weldmuller AAP21 4 DT Modular Distribution Terminals
Product Information
Specifications
-
Standards: EN IEC 60079-0:2018 and EN IEC 60079-7:2015 A1:2018 IEC 60079-0: 7th Edition and IEC 60079-7: 5.1th Edition
-
Modular Terminal Blocks: AAP21 4 DT
-
Order No: 2428980000
-
Accessories: end plate, end bracket, Terminal rail
-
Insulation material: Wemid
-
Tracking resistance (A) to IEC 60112 CTI: 600
-
Flammability class to UL 94: V0
-
Operating temperature range: * in all colours
-
Technical data according to IEC/EN 60079-7 (increased safety ec):
-
AAP21 10 LO…:
-
Rated voltage: 250 V
-
Rated current: 51 A / T < 40 K
-
Contact resistance with rated conductor: 0.4 m
-
Rated conductor cross section: 18 mm
-
Conductor cross section solid: 12 mm
-
Conductor cross section stranded: 12 mm
-
Conductor cross section flexible: 12 mm
-
Cross section, American Wire Gauge: 12 mm
-
Stripping length: 50 cycles
-
AAP21 4 DT:
-
Rated voltage: 250 V
-
Rated current: 19 A / T < 40 K
-
Contact resistance with rated conductor: 1.3 m
-
Rated conductor cross section: 18 mm
-
Conductor cross section solid: 12 mm
-
Conductor cross section stranded: 12 mm
-
Conductor cross section flexible: 12 mm
-
Cross section, American Wire Gauge: 12 mm
-
Stripping length: 50 cycles
-
AAP21 4 FS:
-
Rated voltage: 250 V
-
Rated current: 6.3 A / T < 40 K
-
Contact resistance with rated conductor: 22 A / T < 40
K -
Rated conductor cross section: 4.5 m
-
Conductor cross section solid: 12 mm
-
Conductor cross section stranded: 12 mm
-
Conductor cross section flexible: 12 mm
-
Cross section, American Wire Gauge: 12 mm
-
Stripping length: with dummy fuse link no. 2
-
AAP21 4 LI…:
-
Rated voltage: 250 V
-
Rated current: 6.3 A / T < 40 K
-
Contact resistance with rated conductor: 0.3 m
-
Rated conductor cross section: 12 mm
-
Conductor cross section solid: 12 mm
-
Conductor cross section stranded: 12 mm
-
Conductor cross section flexible: 12 mm
-
Cross section, American Wire Gauge: 12 mm
-
Stripping length: 50 cycles
-
Product Usage Instructions
Mounting Instructions
The disconnect terminals of the A-series are suitable for application in enclosures in atmospheres with flammable gases or combustible dust. For use in flammable gases, these enclosures must satisfy the requirements according to IEC/EN60079-0 and IEC/EN60079-7. For use in combustible dust, these enclosures must satisfy the requirements according to IEC/EN60079-0 and IEC/EN60079-31.
Terminal Block Installation
- Select the appropriate AAP21 4 DT terminal block for your application.
- Ensure that the enclosure meets the requirements for use in flammable gases or combustible dust.
- Install the AAP21 4 DT terminal block securely on the designated terminal rail (TS 35/… acc.to DIN EN 60715).
- If necessary, use the end plate and end bracket accessories to secure the terminal block.
- If cross-connection is required, use the pluggable ZQV 4N/2 to ZQV 4N/10 cross-connection modules.
- Ensure that the terminal block is properly connected to the power supply and distribution terminals according to the allocated currents specified in the manual.
- Verify that all connections are secure and properly insulated.
Terminal Block Maintenance
Regularly inspect the terminal block for any signs of damage or deterioration. If any issues are found, replace the terminal block immediately. Keep the terminal block clean and free from dust and debris.
FAQ
Q: What are the maximum rated voltages for the different terminal block
configurations?
A: The maximum rated voltages are as follows:
- AAP21 10 LO…/ 5 x AAP21 4 FS: 250 V
- AAP21 10 LO…/ 3 x AAP21 4 DT: 250 V
- AAP21 10 LO…/ 2 x AAP21 4 LI…: 250 V
Q: What are the maximum rated currents for the different terminal block
configurations?
A: The maximum rated currents are as follows:
- AAP21 10 LO…: 51 A / T < 40 K
- AAP21 4 LI…: 51 A / T < 40 K
- AAP21 4 DT: 31.5 A / T < 40 K
- AAP21 4 FS: 22 A / T < 40 K
INSTALLATION INSTRUCTIONS & CONDITIONS FOR SAFE USE
Modular TERMINAL Blocks: A- Series
TÜV 16 ATEX 7939 U
IECEx TUR 16.0045 U
TÜV 21 UKEX 7066 U
Standards:
EN IEC 60079-0:2018 and EN IEC 60079-7:2015 A1:2018
IEC 60079-0: 7th Edition and IEC 60079-7: 5.1th Edition
Modular Terminal Blocks: AAP21 4 DT
Version: | AAP21 4 DT* | 2428980000 |
---|---|---|
in conjunction with: | AAP21 4 LI RD* | 2428930000 |
AAP21 4 FS* | 2428950000 | |
AAP21 4 FS 10-36V* | 2458990000 | |
AAP21 4 FS 30-70V* | 2460200000 | |
AAP21 4 FS 60-150V* | 2460190000 | |
AAP21 4 FS 100-250V* | 2460180000 | |
AAP21 10 LO RD* | 2428910000 | |
Accessories: | Type | Order No |
end plate | AEP AP21* | 2429020000 |
end bracket | AEB 35 SC/1* | 1991920000 |
Terminal rail | TS 35/… acc.to DIN EN 60715 | |
Cross-connection | Pluggable | Order No |
ZQV 4N/2* | 1527930000 | |
ZQV 4N/3* | 1527940000 | |
ZQV 4N/4* | 1527970000 | |
ZQV 4N/5* | 1527980000 | |
ZQV 4N/6* | 1527990000 | |
ZQV 4N/7* | 1528020000 | |
ZQV 4N/8* | 1528030000 | |
ZQV 4N/9* | 1528070000 | |
ZQV 4N/10* | 1528090000 |
Insulation material
- Type Wemid
- Tracking resistance (A) to IEC 60112 CTI ≥ 600
- Flammability class to UL 94 V0
- Operating temperature range -60°C…+130°C (insulating material limit)
in all colours
Technical data according to IEC/EN 60079-7 (increased safety “ec”):
| | AAP21 10 LO…| |
---|---|---|---|---
– Rated voltage| | 250 V| |
– Rated current| | 51 A / ΔT < 40 K| |
– Contact resistance with rated conductor| 0,4 mΩ| |
– Rated conductor cross section| 10 mm²| |
– Conductor cross section solid| 0,5 -10mm²| |
– Conductor cross section stranded| 0,5 – 10mm²| |
– Conductor cross section flexible| 0,5 – 10mm²| |
– cross section, American Wire Gauge| 20 – 6 AWG| |
– Stripping length| | 18 mm| |
| | AAP21 4 DT| AAP21 4 FS| AAP21 4 LI…
– Rated voltage| | 250 V| 250 V| 250 V
– Rated current| | 19 A / ΔT < 40 K| 6,3 A / ΔT < 40 K| 22 A / ΔT < 40 K
– Contact resistance with rated conductor| 1,3 mΩ| 4,5 mΩ
with dummy fuse link no. 2
| 0,3 mΩ
– Rated conductor cross section| 4 mm²| 4 mm²| 4 mm²
– Conductor cross section solid| 0,5 – 4mm²| 0,5 – 4mm²| 0,5 – 4mm²
– Conductor cross section stranded| 0,5 – 4mm²| 0,5 – 4mm²| 0,5 – 4mm²
– Conductor cross section flexible| 0,5 – 4mm²| 0,5 – 4mm²| 0,5 – 4mm²
– cross section, American Wire Gauge| 26 – 12 AWG| 26 – 12 AWG| 26 – 12 AWG
– Stripping length| | 12 mm| 12 mm| 12 mm
Service life acc. to IEC 60947-7-1
- max. no. of actuations 50 cycles
IECEx / ATEX / UKCA Terminal and Cross-Connection Arrangements
Max voltage data according to IEC/EN 60079-7 (increased safety “ec”):
Application C ase
A – Continuous feed in with supply terminal and share with distribution terminal blocks
Please attend the details in the technical data above.
Information for further cross-connector arrangements will be provided on request.
Mounting instructions
The disconnect terminals of the A-series are suitable for application in
enclosures in atmospheres with flammable gases or combustible dust. For use in
flammable gases these enclosures must satisfy the requirements according to
IEC/EN60079-0 and IEC/EN60079-7. For use in combustible dust these enclosures
must satisfy the requirements according to IEC/EN60079-0 and IEC/EN60079-31.
In combination with other terminal block series and sizes and if other
accessories are used, the applicable creepage and clearance distances shall be
met.
Regarding the use of accessories the instructions of the manufacturer must be
followed.
Schedule of Limitations:
The disconnect terminal blocks are suitable for use in enclosures in
atmospheres with flammable gases or combustible dust. For flammable gases
these enclosures must satisfy the requirements according to IEC/EN 60079-0 and
IEC/EN 60079-7. For combustible dust these enclosures must satisfy the
requirements according to IEC/EN 60079-31.
The terminal blocks shall be placed inside a suitable IECEx/ATEX certified
IP54 enclosure for gas atmosphere. For dust atmosphere the terminal blocks
shall be mounted inside a suitable IECEx/ATEX certified ‘t’ enclosure
(IEC/EN60079-31).
The enclosure shall be constructed to block all sun and UV light from
affecting the terminal
Under normal operating conditions the temperature rise of the terminal blocks
is max 40 K, measured with the max permitted rated current. Due to the above
mentioned the terminal blocks may be used in apparatus of temperature classes
T6…T1 as long as the terminal block ambient temperature range is not exceeded
as shown below. No part of terminal block must exceed 130 °C under any
condition.
WARNING – Do not remove or replace the test disconnect switch (AAP21 4 DT) when energized!
- Do not remove or replace the test fuse disconnect switch (AAP21 4 FS) when energized!
When using the types of disconnect terminals especially with other terminal blocks series or sizes or accessories the requirements for clearance and creepage distances of EN 60079-7 must be maintained. Regarding the use of covers, cross-connectors and end brackets the instructions of the manufacturer must be followed.
For cross connection accessories current rating, resistance across the terminal please refer to the table under “Technical data” above.
If smaller cross sections than the rated cross section are used, the belonging lower current has to be laid down in the IECEx/EC-Type Examination Certificate of the complete apparatus.
No other wire sizes or types than the ones specified in instructions must be used. The terminal blocks must either be mounted next to another block of the same type and size or with an end plate.
A thermal assessment for the classification into the temperature classes
T6…..T1 shall be performed. No part of terminal block must exceed 130 °C under
any condition.
The terminal blocks may be used, based on the self-heating when used at the
nominal current and at ambient temperatures of – 60 °C to + 40 °C at the
mounting position in electrical apparatus, e.g. junction and connection boxes,
for temperature class T6. when the terminal blocks are used in electrical
apparatus of temperature classes T1 up to T5, the highest temperature of the
insulating material shall not exeed the max. value of the operating
temperature range.
- Cross connections with blank ends shall not be used.
- Manually cut cross connections shall not be used.
Essential Health and Safety Requirements:
Concerning ESRs this Schedule verifies compliance with the Annex II of ATEX /
Schedule 1 of UKCA directive and Equipment and Protective Systems Intended for
Use in Potentially Explosive Atmospheres Regulations 2016 only. By placing the
product on the market, the manufacturer declares compliance with other
relevant Directives, and all other safety related requirements including those
of Annex II / Schedule 1 of these Directives.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>