CAME Logo F A01623M4A
PLX A

FA01623M4A Interphone Mains Libres Came

FA01623M4A Interphone Mains Libres Came - FigFA01623M4A Interphone Mains Libres Came - Fig
1

| VCM/1D| VCM/2D| UTP/CAT 5| 2×2,5mm²
---|---|---|---|---
La, Lb, Lc, Ld| ≤250 m| –| ≤250 m| –
L1, L2, L3| –| ≤100 m| –| –
L1+L2+ L3| –| ≤300 m| –| –
La(Lb, Lc, Ld)+L1(L2, L3)| ≤250 m
La+Lb+Lc+Ld+L1+L2+L3| ≤600 m

FA01623M4A Interphone Mains Libres Came - Fig 2

| VCM/1D| VCM/2D| UTP/CAT 5| 2×2,5mm²
---|---|---|---|---
La, Lb, Lc, Ld| ≤250 m| –| ≤250 m| –
Le| ≤25 m| –| –| ≤60 m
La(Lb, Lc, Ld)+Le| ≤250 m

FA01623M4A Interphone Mains Libres Came - Fig 3

General precautions

  • Read the instructions carefully before beginning the installation and carry out the procedures as specifi ed by the manufacturer.
  • The product must be installed, programmed, commissioned and serviced by qualified technicians, correctly trained with regard to respecting the regulations in force, including implementing accidentprevention measures.
  • Before carrying out any cleaning or maintenance operation, disconnect the power supply.
  • The equipment must only be used for the purpose for which it was designed.
  • The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
  • The product, in its original packaging supplied by the  anufacturer, must only be transported in a closed environment (railway carriage, containers, closed vehicles).
  • If the product malfunctions, stop using it and contact customer services at https://www.came.com/global/en/contact-us or via the telephone number on the website.

The manufacture date is provided in the production batch printed on the product label. If necessary, contact us at https://www.came.com/global/en /contact-us.
The general conditions of sale are given in the offi cial CAME price lists.

Description of PLX A 1 A – 1 B
Intercom internal audio receiver.
Function of terminals M1
BBUS-line input
Landing call
ALAlarm input

Technical data

Type PLX  A
Power supply from BUS (V DC) 15 to 20
Consumption in stand-by mode (mA) <1
Maximum consumption (mA) 30
Single LED consumption (mA) 1
Storage temperature (°C)* -25 to +70
Operating temperature (°C) +5 to +40
IP Rating IP 30
Average life (hours)** 150,000

(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life is a purely indicative estimate.  It applies to compliant usage, installation and maintenance conditions. It is also influenced by other factors, such as climatic and environmental conditions.

Installation 2

  • Prise open the device by inserting a screwdriver, preferably a flat-head screwdriver measuring 5.5 mm, in the slot in the bottom of the device as shown in 2 A and lifting it upwards as shown in 2 B.
  • Separate the shell from the bottom of the device.
  • Thread the connection wires through the hole in the bottom.
  • Fasten the bottom of the device to the box on the wall 3 A – 3 B – 3 C.

The box must be installed at an appropriate height for the user. Avoid overtightening the screws.
Make the connections, then reattach the shell to the bottom of the device 4.

Connection examples

5 Installation limits for systems powered by VA/01.
6 Installation limits for systems powered by VAS/101.

Configuring melodies 7

  Perform each of the following configuration steps one after the other:

  1. Entering configuration mode
    Press and hold the button for 3 seconds.
    You will hear a short beep and see a red flashing LED to confirm that you have entered configuration mode A.

  2. Configuring the melody associated with the entry panel call
    To listen to the melodies in sequence, press the button B.
    To select the melody and exit configuration mode, press the button C.
    To select the melody and continue configuration, press the button.
    You will hear two short beeps to confirm that you have entered landing call configuration mode D.

  3. Configuring the landing call melody
    To listen to the melodies in sequence, press the button E.
    To select the melody and exit configuration mode, press the button F.
    To select the melody and continue configuration, press the button.
    You will hear three short beeps to confirm that you have entered configuration mode for the number of rings per call G.

  4. Configuring the number of rings per call
    Press the button as many times as the number of rings you want (from 1 to 12 rings) H.
    Three seconds after the button is last pressed, the selected call will be played back with the chosen number of rings. To exit configuration mode, press the button I.
    To program a call, please see the entry panel manuals.

  5. Function setting for buttons 1-4
    Buttons 1-4 can be configured as intercom calls (default) or auxiliary commands by setting the relevant SW1 dipswitch positions (see Table for the 1-4 front button functions according to the position of dipswitches SW1-1 to 1-4).

Legislative references
This product complies with the applicable standards in force at the time of manufacturing.
FCC – This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference / (2) this device must accept any interference received, including interference that may cause undesired operation.
The product complies with the relevant directives in force.
Dismantling and disposal. Dispose of the packaging and the device responsibly at the end of its life cycle, in compliance with the laws in force in the country where the product is used. The recyclable components are marked with a symbol and the material ID marker.
THE DATA AND INFORMATION IN THIS MANUAL ARE SUBJECT TOCHANGE AT ANY TIME AND WITHOUT ANY ADVANCE WARNING. UNLESS OTHERWISE INDICATED, MEASUREMENTS ARE GIVEN IN MILLIMETRES.

FA01623M4A – 11/2022
Translation of the original instructions

CAME S.p .A.
Via Martiri Della Libertà, 15
31030 – Dosson di Casier
Treviso – Italy
tel. (+39) 0422 4940
fax. (+39) 0422 4941
info@came.com
www.came.com
came.com
FA01623M4A – 11/2022

Documents / Resources

| CAME FA01623M4A Interphone Mains Libres Came [pdf] Instruction Manual
FA01623M4A Interphone Mains Libres Came, FA01623M4A, Interphone Mains Libres Came, Mains Libres Came, Libres Came, Came
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals