TECHNICAL SPECIFICATIONS
Model PGC2TE Series
SmartStart®
M1200 Product Line
Two Stage, Fixed Speed ECM, High Efficiency
Upflow Gas Furnaces
96% AFUE Input 60,000-115,000 Btuh
The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
Features and Benefits
– Multi-Speed Direct Drive Blower: Energy-efficient brushless DC (ECM)
fixed-speed motor offers 16 speeds designed to give a wide range of cooling
capacities.
– Two Stage Inducer: Optimizes efficiency on first stage heat and reduces
sound levels.
– 100% Fired and Tested: All units and each component are tested on the
manufacturing line.
– Best Packaging in the Industry: Unique corner post design assures
product will arrive to the homeowner dent free.
– 30 Second Blower Delay: At start-up assures a warm duct temperature at
furnace start-up. Adjustable blower off settings (60, 90, 120 and 180
seconds).
– 30 Second Post Purge : Increases life of heat exchanger.
– Hot Surface Igniter : Innovative application of an appliance type
igniter with a 20 year history of reliability. Utilizes proven SmartStart ®
technology.
– Color Coded Wire Harness: Designed to fit the components, all with
quick-connect fittings for ease of service and replacement.
– Flexible Category IV Venting System: May be vertically or horizontally
vented using either a one-pipe or two-pipe system for maximum flexibility in
installation.
– High Static Blowers: All models equipped with high static ECM blowers.
– Low Boy Height: Easy to apply in low ceiling applications, works well
with taller high SEER coils, easier to handle and install.
– Heat Exchanger: Heavy gauge aluminized steel primary heat exchanger and
stainless steel secondary heat exchanger assures a long life.
– 60 Second Fixed Cooling Cycle Blower-Off Delay (TDR): Increases cooling
performance when matched with a Nortek Global HVAC evaporator coil.
– LP Convertible: Simple burner orifice and regulator spring change for
ease of convertibility (as an accessory).
– Diagnostic Lights: Dedicated light for flame signal strength and 2
lights in combination to indicate all other fault codes with easy to recognize
states without counting flashes.
– Integrated Control Boards: With connections for electronic air cleaner,
humidifier, and dehumidification. Ergonomically located for ease of service.
– Two Piece Door Design: Enhances furnace appearance and uses captured
screws to prevent losing door screws.
– Blower Compartment: Sealed door to reduce air leakage and insulated for
ultra quiet operation.
– Sealed Vestibule: Reduces burner and inducer sound levels.
– Furnace Air Leakage: These furnaces comply with Energy Star cabinet air
leakage requirement of less than or equal to 2%. Keep the conditioned air
flowing to where it’s needed.
GAS FURNACE COMPONENTS
LOCATION OF FURNACE COMPONENTS
*UPFLOW FURNACE (TE SERIES)**
Upflow Gas Furnace Components
- Finish Flange
- Roll-Out Switch
- Burner Assembly
- Igniter
- Gas Valve
- Furnace Control Board
- Pressure Switches (Condensate)
- Transformer
- Motor Control Board
- Blower Assembly
- Motor Choke (C & D cabinets only)
- Motor Control Box
- Blower Door Switch
- Inducer Assembly
- Inducer Limit Switch
- Main Air Limit Switch
- Pressure Switches (Inducer)
- Flame Sensor
DIMENSIONS
*TE
Model #s| Dimension
“A”| Dimension
“B”| Dimension
“C”
---|---|---|---
060DVB1|
17 1/2
| 15 7/8|
16 1/8
080DVC1|
21
| 19 3/8|
19 5/8
100DVC1
115DVD1|
24 1/2
| 22 7/8|
23 1/8
TOP VIEW
- FLANGES
- Combustion Air
BOTTOM VIEW
- Front Brace
- Bottom Panel
LEFT SIDE
- Vent pipe (Ø 3”)
- T-stat (Ø 7/8)
- Electric (Ø 7/8)
- Gas (Ø 1 5/8)
- Condensate (Ø 1 1/16)
FRONT VIEW
RIGHT SIDE
- Vent pipe (Ø 3”)
- T-stat (Ø 7/8)
- Electric (Ø 7/8)
- Gas (Ø 1 5/8)
- 4 Knockouts (both sides)
- Cond. (Ø 1 1/16)
PGC2TE 96% High Efficiency Upflow Series
IDENTIFICATION CODE
MODEL IDENTIFICATION CODE
-
Gas Furnace
-
Design Series
-
S = Single Stage
T = Two Stage
M = Modulating -
A = 80% Upflow/Horizontal
C = 92.1% / 95.1% Upflow/Horizontal
D = 95% Upflow/Horizontal
E = 96% Upflow
Q = 96.4+% AFUE Upflow/Horizontal -
Input Heating Capacity
045 = 45,000
054 = 54,000
072 = 72,000
090 = 90,000
108 = 108,000
126 = 126,000 -
NOx
C/D = 40 Ng/J or less NOx
U = 14 Ng/J or less NOx -
Motor Technology
V = VSHE
E = FSHE
T = 5 Tap ECM -
Cooling Airflow
23 = 2-3 Tons
24 = 2-4 Tons
35 = 3-5 Tons
45 = 4-5 Tons -
Cabinet Width
A = 14.25
B = 17.50
C = 21.00
D = 24.50 -
Revision
SPECIFICATIONS
PGC2TE MODEL NUMBERS:|
060DE24B1
| 080DE35C1| 100DE35C1|
115DE45D1
---|---|---|---|---
Input – Btuh (a)|
60000 / 39000
| 80000 / 52000| 100000 / 65000|
115000 / 74750
Heating Capacity – BtuH|
58000 / 37000
| 77000 / 50000| 96000 / 62000|
110000 / 72000
AFUE|
96.0
| 96.0| 96.0|
96.0
Motor H.P. – Speed – Type|
3/4 – BLDC
| 1 – BLDC| 1 – BLDC|
1 – BLDC
Motor FLA|
8.8
| 11.5| 11.5|
11.5
Rated Ext. SP – In. W.C.|
0.50
| 0.50| 0.50|
0.50
Temperature Rise Range – F|
30-60
| 30-60| 35-65|
40-70
Shipping Weights|
120 lb
| 130 lb| 135 lb|
145 lb
SKU|
1025958P
| 1025959P| 1025960P|
1025961P
Note:
All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel
Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea
level.
BLOWER PERFORMANCE PGC2TE
G7TE-060D-E24B1 (FSHE)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE|
CFM| RISE| CFM| RISE| CFM|
RISE
G7TE-060D-E24B1 60,000 BTU/hr
| 0| 0| 0| 0| | | | | | | | | |
1| 0| 0|
0
| | | | | | | | | |
0
| 1| 0| 0| | | | | | | | | |
1| 1| 0|
0
| | | | | | | | | |
0
| 0| 1| 0| | | | | | | | | |
1| 0| 1| 0| 940| 57| 890|
60
| | | | | |
0
| 1| 1| 0| 990| 54| 945| 56| 905| 59| | | |
1| 1| 1| 0| 1,055| 51| 1,015| 53| 970| 55| 930| 57| 890|
60
0
| 0| 0| 1| 1,135| 47| 1,095| 49| 1,055| 51| 1,010| 53| 960| 56
1| 0| 0| 1| 1,185| 45| 1,145| 47| 1,105| 48| 1,065| 50| 1,030|
52
0
| 1| 0| 1| 1,250| 43| 1,210| 44| 1,170| 46| 1,135| 47| 1,095| 49
1| 1| 0| 1| 1,290| 41| 1,255| 42| 1,220| 44| 1,180| 45| 1,145|
47
0
| 0| 1| 1| 1,315| 41| 1,275| 42| 1,240| 43| 1,200| 44| 1,160| 46
1| 0| 1| 1| 1,350| 40| 1,315| 41| 1,280| 42| 1,245| 43| 1,205|
44
0
| 1| 1| 1| 1,390| 38| 1,350| 40| 1,315| 41| 1,275| 42| 1,240| 43
1| 1| 1|
1
| | | | | | | | | |
COOLING AIRFLOW (CFM)
Model Number/ Heating Input
| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| CFM| CFM| CFM| CFM|
CFM| CFM| CFM|
CFM
G7TE-060D-E24B1 60,000 BTU/hr
|
0
| 0| 0| 0| | | | | | | |
1| 0| 0|
0
| | | | | | | |
0
| 1| 0| 0| | | | | | | |
1| 1| 0| 0|
725
| | | | | | |
0
| 0| 1| 0| 810| | | | | | |
1| 0| 1| 0| 940| 890| 845| 795| 750|
700
| |
0
| 1| 1| 0| 990| 945| 905| 860| 820| 775| 735| 690
1| 1| 1| 0| 1,055| 1,015| 970| 930| 890| 845| 805|
760
0
| 0| 0| 1| 1,135| 1,095| 1,055| 1,010| 960| 930| 890| 850
1| 0| 0| 1| 1,185| 1,145| 1,105| 1,065| 1,030| 990| 950|
910
0
| 1| 0| 1| 1,250| 1,210| 1,170| 1,135| 1,095| 1,055| 1,020| 980
1| 1| 0| 1| 1,290| 1,255| 1,220| 1,180| 1,145| 1,110| 1,075|
1,040
0
| 0| 1| 1| 1,315| 1,275| 1,240| 1,200| 1,160| 1,120| 1,085| 1,045
1| 0| 1| 1| 1,350| 1,315| 1,280| 1,245| 1,205| 1,170| 1,135|
1,100
0
| 1| 1| 1| 1,390| 1,350| 1,315| 1,275| 1,240| 1,200| 1,160| 1,125
1| 1| 1| 1| 1,420| 1,380| 1,345| 1,310| 1,270| 1,235| 1,200|
1,160
-
NOTES:
- Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
- To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
- To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
- When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).
PGC2TE-080D-E35C1 (FSHE)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE|
CFM| RISE| CFM| RISE| CFM|
RISE
PGC2TE-080D-E35C1
80,000 BTU/hr
|
0
| 0| 0| 0| 1,125| 63| | | | | | | |
1| 0| 0| 0| 1,205| 59| 1,120|
63
| | | | | |
0
| 1| 0| 0| 1,305| 54| 1,225| 58| 1,150| 62| | | |
1| 1| 0| 0| 1,430| 50| 1,350| 53| 1,270| 56| 1,190| 60| 1,110|
63
0
| 0| 1| 0| 1,525| 47| 1,450| 49| 1,375| 52| 1,300| 55| 1,225| 57
1| 0| 1| 0| 1,620| 44| 1,540| 46| 1,465| 49| 1,390| 51| 1,315|
54
0
| 1| 1| 0| 1,695| 42| 1,620| 44| 1,545| 46| 1,465| 49| 1,390| 51
1| 1| 1| 0| 1,770| 40| 1,700| 42| 1,630| 44| 1,555| 46| 1,485|
47
0
| 0| 0| 1| 1,875| 38| 1,805| 39| 1,730| 41| 1,655| 43| 1,580| 45
1| 0| 0| 1| 1,905| 37| 1,840| 39| 1,775| 40| 1,710| 42| 1,640|
43
0
| 1| 0| 1| 1,980| 36| 1,910| 37| 1,845| 39| 1,780| 40| 1,715| 41
1| 1| 0| 1| 2,025| 35| 1,960| 36| 1,895| 38| 1,830| 39| 1,765|
40
0
| 0| 1| 1| | | 2,025| 35| 1,960| 36| 1,900| 37| 1,840| 38
1| 0| 1| 1| | | | | 2,010| 35| 1,945| 37| 1,880|
37
0
| 1| 1| 1| | | | | | | 2,035| 35| 1,980| 36
1| 1| 1| 1| | | | | | | | | |
COOLING AIRFLOW (CFM)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| CFM| CFM| CFM| CFM|
CFM| CFM| CFM|
CFM
PGC2TE-080D-E35C1 80,000 BTU/hr
|
0
| 0| 0| 0| 1,125| 1,040| 960| 880| 795| | |
1| 0| 0| 0| 1,205| 1,120| 1,040| 960| 875|
795
| |
0
| 1| 0| 0| 1,305| 1,225| 1,150| 1,070| 995| 915| 840|
1| 1| 0| 0| 1,430| 1,350| 1,270| 1,190| 1,110| 1,030| 950|
865
0
| 0| 1| 0| 1,525| 1,450| 1,375| 1,300| 1,225| 1,150| 1,075| 1,000
1| 0| 1| 0| 1,620| 1,540| 1,465| 1,390| 1,315| 1,240| 1,165|
1,090
0
| 1| 1| 0| 1,695| 1,620| 1,545| 1,465| 1,390| 1,315| 1,235| 1,160
1| 1| 1| 0| 1,770| 1,700| 1,630| 1,555| 1,485| 1,410| 1,340|
1,265
0
| 0| 0| 1| 1,875| 1,805| 1,730| 1,655| 1,580| 1,510| 1,435| 1,340
1| 0| 0| 1| 1,905| 1,840| 1,775| 1,710| 1,640| 1,575| 1,510|
1,445
0
| 1| 0| 1| 1,980| 1,910| 1,845| 1,780| 1,715| 1,650| 1,580| 1,515
1| 1| 0| 1| 2,025| 1,960| 1,895| 1,830| 1,765| 1,700| 1,635|
1,570
0
| 0| 1| 1| 2,085| 2,025| 1,960| 1,900| 1,840| 1,775| 1,715| 1,655
1| 0| 1| 1| 2,135| 2,070| 2,010| 1,945| 1,880| 1,815| 1,750|
1,685
0
| 1| 1| 1| 2,200| 2,145| 2,090| 2,035| 1,980| 1,925| 1,870| 1,820
1| 1| 1| 1| 2,280| 2,225| 2,170| 2,115| 2,065| 2,010| 1,955|
1,900
*NOTES:
- Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
- To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
- To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
- When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).
PGC2TE-100D-E35C1 (FSHE)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE|
CFM| RISE| CFM| RISE| CFM|
RISE
PGC2TE-100D-E35C1 100,000 BTU/hr
|
0
| 0| 0| 0| | | | | | | | | |
1| 0| 0|
0
| | | | | | | | | |
0
| 1| 0| 0| | | | | | | | | |
1| 1| 0|
0
| | | | | | | | | |
0
| 0| 1| 0| | | | | | | | | |
1| 0| 1| 0| 1,620| 55| 1,540|
58
| | | | | |
0
| 1| 1| 0| 1,695| 52| 1,620| 55| 1,545| 58| | | |
1| 1| 1| 0| 1,770| 50| 1,700| 52| 1,630| 55| 1,555| 57| 1,485|
60
0
| 0| 0| 1| 1,875| 47| 1,805| 49| 1,730| 51| 1,655| 54| 1,580| 56
1| 0| 0| 1| 1,905| 47| 1,840| 48| 1,775| 50| 1,710| 52| 1,640|
54
0
| 1| 0| 1| 1,980| 45| 1,910| 47| 1,845| 48| 1,780| 50| 1,715| 52
1| 1| 0| 1| 2,025| 44| 1,960| 45| 1,895| 47| 1,830| 49| 1,765|
50
0
| 0| 1| 1| 2,085| 43| 2,025| 44| 1,960| 45| 1,900| 47| 1,840| 48
1| 0| 1| 1| 2,135| 42| 2,070| 43| 2,010| 44| 1,945| 46| 1,880|
47
0
| 1| 1| 1| | | | | | | | | |
1| 1| 1| 1| | | | | | | | | |
COOLING AIRFLOW (CFM)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| CFM| CFM| CFM| CFM|
CFM| CFM| CFM|
CFM
PGC2TE-100D-E35C1 100,000 BTU/hr
|
0
| 0| 0| 0| 1,125| 1,040| | | | | |
1| 0| 0| 0| 1,205| 1,120|
1,040
| | | | |
0
| 1| 0| 0| 1,305| 1,225| 1,150| 1,070| 995| | |
1| 1| 0| 0| 1,430| 1,350| 1,270| 1,190| 1,110|
1,030
| |
0
| 0| 1| 0| 1,525| 1,450| 1,375| 1,300| 1,225| 1,150| 1,075| 1,000
1| 0| 1| 0| 1,620| 1,540| 1,465| 1,390| 1,315| 1,240| 1,165|
1,090
0
| 1| 1| 0| 1,695| 1,620| 1,545| 1,465| 1,390| 1,315| 1,235| 1,160
1| 1| 1| 0| 1,770| 1,700| 1,630| 1,555| 1,485| 1,410| 1,340|
1,265
0
| 0| 0| 1| 1,875| 1,805| 1,730| 1,655| 1,580| 1,510| 1,435| 1,340
1| 0| 0| 1| 1,905| 1,840| 1,775| 1,710| 1,640| 1,575| 1,510|
1,445
0
| 1| 0| 1| 1,980| 1,910| 1,845| 1,780| 1,715| 1,650| 1,580| 1,515
1| 1| 0| 1| 2,025| 1,960| 1,895| 1,830| 1,765| 1,700| 1,635|
1,570
0
| 0| 1| 1| 2,085| 2,025| 1,960| 1,900| 1,840| 1,775| 1,715| 1,655
1| 0| 1| 1| 2,135| 2,070| 2,010| 1,945| 1,880| 1,815| 1,750|
1,685
0
| 1| 1| 1| 2,200| 2,145| 2,090| 2,035| 1,980| 1,925| 1,870| 1,820
1| 1| 1| 1| 2,280| 2,225| 2,170| 2,115| 2,065| 2,010| 1,955|
1,900
*NOTES:
- Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
- To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
- To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
- When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).
PGC2TE-115D-E45D1 (FSHE)
HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5
1| 2| 3| 4| CFM| RISE| CFM| RISE|
CFM| RISE| CFM| RISE| CFM|
RISE
PGC2TE-115D-E45D1 115,000 BTU/hr
| 0| 0| 0| 0| | | | | | | | | |
1| 0| 0|
0
| | | | | | | | | |
0
| 1| 0| 0| | | | | | | | | |
1| 1| 0|
0
| | | | | | | | | |
0
| 0| 1| 0| | | | | | | | | |
1| 0| 1| 0| 1,760| 58| 1,715|
60
| | | | | |
0
| 1| 1| 0| 1,835| 56| 1,790| 57| 1,745| 59| | | |
1| 1| 1| 0| 1,885| 54| 1,840| 56| 1,790| 57| 1,745| 59| 1,700|
60
0
| 0| 0| 1| 1,945| 53| 1,900| 54| 1,850| 55| 1,805| 57| 1,760| 58
1| 0| 0| 1| 1,950| 52| 1,905| 54| 1,860| 55| 1,820| 56| 1,775|
58
0
| 1| 0| 1| 2,075| 49| 2,030| 50| 1,990| 51| 1,945| 53| 1,900| 54
1| 1| 0| 1| 2,125| 48| 2,085| 49| 2,040| 50| 2,000| 51| 1,955|
52
0
| 0| 1| 1| 2,170| 47| 2,130| 48| 2,090| 49| 2,045| 50| 2,005| 51
1| 0| 1| 1| 2,215| 46| 2,180| 47| 2,140| 48| 2,105| 49| 2,070|
49
0
| 1| 1| 1| | | | | | | | | |
1| 1| 1|
1
| | | | | | | | | |
COOLING AIRFLOW (CFM)
Model Number/ Heating Input| MOTOR SWITCH SETTINGS (0=OFF, 1=ON)|
External Static Pressure (in.w.c.)
0.1
| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
5| 6| 7| 8| CFM| CFM| CFM| CFM|
CFM| CFM| CFM|
CFM
PGC2TE-115D-E45D1 115,000 BTU/hr
| 0| 0| 0| 0| 1,395| 1,350| 1,305| 1,260| 1,210| 1,165| 1,120|
1| 0| 0| 0| 1,465| 1,420| 1,375| 1,330| 1,290| 1,245| 1,200|
1,155
0
| 1| 0| 0| 1,555| 1,510| 1,470| 1,425| 1,380| 1,340| 1,295| 1,250
1| 1| 0| 0| 1,625| 1,585| 1,540| 1,500| 1,460| 1,415| 1,375|
1,335
0
| 0| 1| 0| 1,690| 1,650| 1,610| 1,570| 1,530| 1,485| 1,445| 1,405
1| 0| 1| 0| 1,760| 1,715| 1,670| 1,625| 1,575| 1,530| 1,485|
1,440
0
| 1| 1| 0| 1,835| 1,790| 1,745| 1,695| 1,650| 1,605| 1,555| 1,510
1| 1| 1| 0| 1,885| 1,840| 1,790| 1,745| 1,700| 1,655| 1,610|
1,565
0
| 0| 0| 1| 1,945| 1,900| 1,850| 1,805| 1,760| 1,710| 1,665| 1,620
1| 0| 0| 1| 1,950| 1,905| 1,860| 1,820| 1,775| 1,735| 1,690|
1,650
0
| 1| 0| 1| 2,075| 2,030| 1,990| 1,945| 1,900| 1,855| 1,810| 1,770
1| 1| 0| 1| 2,125| 2,085| 2,040| 2,000| 1,955| 1,910| 1,870|
1,825
0
| 0| 1| 1| 2,170| 2,130| 2,090| 2,045| 2,005| 1,965| 1,925| 1,880
1| 0| 1| 1| 2,215| 2,180| 2,140| 2,105| 2,070| 2,035| 2,000|
1,965
0
| 1| 1| 1| | | | | 2,225| 2,165| 2,100| 2,040
1| 1| 1| 1| | | | | | 2,170| 2,120|
2,065
*NOTES:
- Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
- To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
- Data is shown without filter.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
- To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
- When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).
ACCESSORIES
PGC2TE KITS
Description|
SKU
2″ Concentric Vent Kit|
904177
3″ Concentric Vent Kit|
904176
2″ Concentric Vent Kit (Canadian Approved)|
904952
3″ Concentric Vent Kit (Canadian Approved)|
904953
2″ Side Wall Vent Kit|
904617
3″ Side Wall Vent Kit|
904347
U.S. LP Conversion Kit (0 to 10,000 ft.)|
905028
Canada LP Conversion Kit (0 to 4,500 ft.)|
905029
Bottom Return Filter 20 per Box, “B” Cabinet|
904916
Bottom Return Filter 20 per Box, “D” Cabinet|
904918
Side Return Filter Kit|
541036
Neutralizer Kit|
902377
VENTING
All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.
FURNACE MODELS (BTU)
| FURNACE INSTALLATION| SINGLE PIPE LENGTH (FT.) with 1 long radius elbow**|
DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH 1 long radius elbow on each pipe**
---|---|---|---
OUTLET
| OUTLET| INLET/OUTLET| INLET/OUTLET
2” Diameter| 3” Diameter| 2” Diameter|
3” Diameter
60,000
| Upflow| 90| 90| 90| 90
80,000| Upflow| 40| 90| 40|
90
100,000
| Upflow| 30| 90| 30| 90
115,000| Upflow| N/A| 90| N/A|
90
*NOTES:
- Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
- Two 45 degree elbows are equivalent to one 90 degree elbow.
- This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations.
Manufactured under license by Nortek Global HVAC, LLC, O’Fallon, MO.
®Registered Trademark/ ™ Trademark of Maytag Corporation or its related
companies. © Nortek Global HVAC, LLC 2019. All rights reserved.
®/™/© Maytag. All rights reserved. Manufactured under license by Nortek Global
HVAC, LLC, Missouri, USA. Limited warranty provided by the manufacturer. ©
Nortek Global HVAC, LLC. All rights reserved.
484F-0619
Printed in U.S.A. (06/19)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>